SearcharxivSearch

arXiv subjects

M. Malnou

Publications and source records attributed to M. Malnou.

At least 19 recordsLinked to original sources

A Traveling-Wave Parametric Amplifier With Integrated Diplexers

Traveling-Wave Parametric Amplifiers (TWPAs) are ubiquitous in superconducting circuit readout, providing high gain with near-quantum-limited noise performance across a wide bandwidth. Their operation, however, relies on a strong microwave pump tone that is typically delivered using off-chip passive components, such as directional couplers or diplexers. These external elements add loss, increase system complexity, and limit scalability. Here, we present a traveling-wave parametric amplifier that incorporates on-chip input and output diplexers for pump routing. This co-fabricated architecture offers a compact and scalable solution for superconducting-circuit readout.

quant-ph

Artificial Transmission Line Synthesis Tailored for Traveling-Wave Parametric Processes

Artificial transmission lines built with lumped-element inductors and capacitors form the backbone of broadband, nearly quantum-limited traveling-wave parametric amplifiers (TWPAs). When tailoring these transmission lines for parametric processes, nonlinear elements are added, typically nonlinear inductances in superconducting circuits, and energy and momentum conservation between interacting tones must be enforced through careful design of the ATL dispersion relation. However, a unified theoretical framework describing achievable dispersion relations is lacking. Here, I develop such a framework, borrowing from periodic structure theory and passive network synthesis. These complementary approaches divide the design space: periodic loading synthesis employs spatial modulation of frequency-independent components, while filter synthesis employs frequency-dependent responses in spatially-uniform components. The framework reveals fundamental constraints and enables the discovery of novel TWPA architectures. In particular, I design a kinetic inductance TWPA with a novel phase-matching architecture, and a backward-pumped Josephson TWPA exploiting an ambidextrous i.e., right-left-handed transmission line.

physics.app-ph

A Traveling-Wave Parametric Amplifier and Converter

High-fidelity qubit measurement is a critical element of all quantum computing architectures. In superconducting systems, qubits are typically measured by probing a readout resonator with a weak microwave tone that must be amplified before reaching the room temperature electronics. Superconducting parametric amplifiers have been widely adopted as the first amplifier in the chain, primarily because of their low noise performance, approaching the quantum limit. However, they require isolators and circulators to route signals up the measurement chain and to protect qubits from amplified noise. While these commercial components are wideband and simple to use, their intrinsic loss, size, and magnetic shielding requirements impact overall measurement efficiency and scalability. Here we report a parametric amplifier that achieves both broadband forward amplification and backward isolation in a single, compact, non-magnetic circuit that could be integrated on chip with superconducting qubits. The approach relies on a nonlinear transmission line that supports traveling-wave parametric amplification of forward propagating signals, and isolation via frequency conversion of backward propagating signals. This traveling-wave parametric amplifier and converter has the potential to reduce the readout hardware overhead when scaling up the size of superconducting quantum computers.

quant-ph

Characterization of NbTiN films with thicknesses below 20 nm for low power kinetic inductance amplifiers

A quantum-limited amplification chain is a fundamental advantage for any application that may benefit from the detection of very faint signals. Reading out arrays of superconducting detectors (TESs or MKIDs), resonant cavities, or qubits, calls for large bandwidth amplifiers in addition to having the lowest possible noise. At millikelvin temperatures, Kinetic Inductance Traveling-Wave Parametric Amplifiers (KI-TWPAs) working in 3-wave-mixing (3WM) and fabricated from a 20 nm thick NbTiN film have shown promising noise performances, as they can operate close to the quantum limit. However, they still require fairly high pump power. Devices that would require lower pump power would be easier to implement in readout chains, could reach the quantum limit and they would be compatible with qubit readout. A possible solution for obtaining this optimal configuration is to use a thinner superconducting film. In this work we explore the properties of NbTiN films with a thickness less than 20 nm and we report the obtained experimental characterizations in terms of critical temperature, normal resistivity, and kinetic inductance. A new design for a 3WM KI-TWPA amplifier, based on these developed superconducting films, is introduced and discussed.

cond-mat.supr-con

Low-noise cryogenic microwave amplifier characterization with a calibrated noise source

Parametric amplifiers have become a workhorse in superconducting quantum computing, however research and development of these devices has been hampered by inconsistent, and sometimes misleading noise performance characterization methodologies. The concepts behind noise characterization are deceptively simple, and there are many places where one can make mistakes, either in measurement or interpretation and analysis. In this article we cover the basics of noise performance characterization, and the special problems it presents in parametric amplifiers with limited power handling capability. We illustrate the issues with three specific examples: a high-electron mobility transistor amplifier, a Josephson traveling-wave parametric amplifier, and a Josephson parametric amplifier. We emphasize the use of a 50-$Ω$ shot noise tunnel junction (SNTJ) as a broadband noise source, demonstrating its utility for cryogenic amplifier amplifications. These practical examples highlight the role of loss as well as the additional parametric amplifier `idler' input mode.

quant-ph

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from $1.6$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA off, to $0.77$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA on. When statically biasing the umux to the maximally flux-sensitive point, the flux noise drops from $0.45$ $μΦ_0/\sqrt{\mathrm{Hz}}$ to $0.2$ $μΦ_0/\sqrt{\mathrm{Hz}}$. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the umux and detecting background radiation. The combination of umux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

astro-ph.IM

New Results from HAYSTAC's Phase II Operation with a Squeezed State Receiver

A search for dark matter axions with masses $>10 μeV/c^{2}$ has been performed using the HAYSTAC experiment's squeezed state receiver to achieve sub-quantum limited noise. This report includes details of the design and operation of the experiment previously used to search for axions in the mass ranges $16.96-17.12$ and $17.14-17.28 μeV/c^{2}$($4.100-4.140$GHz) and $4.145-4.178$GHz) as well as upgrades to facilitate an extended search at higher masses. These upgrades include improvements to the data acquisition routine which have reduced the effective dead time by a factor of 5, allowing for the new region to be scanned $\sim$1.6 times faster with comparable sensitivity. No statistically significant evidence of an axion signal is found in the range $18.44-18.71μeV/c^{2}$($4.459-4.523$GHz), leading to an aggregate upper limit exclusion at the $90\%$ level on the axion-photon coupling of $2.06\times g_γ^{KSVZ}$.

hep-ex

Performance of a Kinetic-Inductance Traveling-Wave Parametric Amplifier at 4 Kelvin: Toward an Alternative to Semiconductor Amplifiers

Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable noise performance, a conventional HEMT dissipates several milliwatts of power, posing a practical challenge to scale up the number of qubits or sensors addressed in these architectures. As an alternative, we present an amplification chain consisting of a kinetic-inductance traveling-wave parametric amplifier (KI-TWPA) placed at 4 K, followed by a HEMT placed at 70 K, and demonstrate a chain-added noise $T_Σ= 6.3\pm0.5$ K between 3.5 and 5.5 GHz. While, in principle, any parametric amplifier can be quantum limited even at 4 K, in practice we find the KI-TWPA's performance limited by the temperature of its inputs, and by an excess of noise $T_\mathrm{ex} = 1.9$ K. The dissipation of the KI-TWPA's rf pump constitutes the main power load at 4 K and is about one percent that of a HEMT. These combined noise and power dissipation values pave the way for the KI-TWPA's use as a replacement for semiconductor amplifiers.

quant-ph

Sub-Kelvin Thermometer for On-Chip Measurements of Microwave Devices Utilizing Two-Level Systems in Superconducting Microresonators

We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the sensitivity (50-75~$μ$K/$\sqrt{\mathrm{Hz}}$) is relatively uniform across this range. The miniature footprint that conveniently attaches to the feedline of a cryogenic microwave device facilitates the measurement of on-chip device temperature and requires no additional thermometry wiring or readout electronics. We demonstrate the practical use of these TLS thermometers to investigate static and transient chip heating in a kinetic inductance traveling-wave parametric amplifier operated with a strong pump tone. TLS thermometry may find broad application in cryogenic microwave devices such as superconducting qubits and detectors.

physics.ins-det

A three-wave mixing kinetic inductance traveling-wave amplifier with near-quantum-limited noise performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave amplifier (KIT), whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, the KIT operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT devices. It consists of a 50 Ohms artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{-1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of -63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT, we measure the system-added noise of an amplification chain that integrates the KIT as the first amplifier. This system-added noise, $3.1\pm0.6$ quanta (equivalent to $0.66\pm0.15$ K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

quant-ph

Squeezed vacuum used to accelerate the search for a weak classical signal

Many experiments that interrogate fundamental theories require detectors whose sensitivities are limited by the laws of quantum mechanics. In cavity-based searches for axionic dark matter, vacuum fluctuations in the two quadratures of the cavity electromagnetic field limit the sensitivity to an axion-induced field. In an apparatus designed to partially mimic existing axion detectors, we demonstrate experimentally that such quantum limits can be overcome through the use of squeezed states. By preparing a microwave cavity in a squeezed state and measuring just the squeezed quadrature, we enhance the spectral scan rate by a factor of $2.12 \pm 0.08$. This enhancement is in excellent quantitative agreement with a theoretical model accounting for both imperfect squeezing and measurement.

quant-ph

A quantum-enhanced search for dark matter axions

In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we double the search rate for axions over a mass range favored by recent theoretical projections. We observe no signature of dark matter axions in the combined $16.96-17.12$ and $17.14-17.28\spaceμ\text{eV}/c^2$ mass window for axion-photon couplings above $g_γ = 1.38\times g_γ^\text{KSVZ}$, reporting exclusion at the 90% level.

quant-ph

An improved analysis framework for axion dark matter searches

In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_γ$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $μ$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.

astro-ph.IM

Results from phase 1 of the HAYSTAC microwave cavity axion experiment

We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature $T<hν/2k_B$ and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment's system noise temperature to only twice the Standard Quantum Limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA.

hep-ex

Optimal operation of a Josephson parametric amplifier for vacuum squeezing

A Josephson parametric amplifier (JPA) can create squeezed states of microwave light, lowering the noise associated with certain quantum measurements. We experimentally study how the JPA's pump influences the phase-sensitive amplification and deamplification of a coherent tone's amplitude when that amplitude is commensurate with vacuum fluctuations. We predict and demonstrate that by operating the JPA with a pump power greater than the value that maximizes gain, the amplifier distortion is reduced and consequently squeezing is improved. Optimizing the JPA's operation in this fashion, we directly observe $3.87 \pm 0.03$ dB of vacuum squeezing.

quant-ph

Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range

We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.

physics.ins-det

First results from a microwave cavity axion search at 24 micro-eV

We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~μ\text{eV}$. We exclude axion models with two-photon coupling $g_{aγγ} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~μ\text{eV} < m_a < 24.0~μ\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an order of magnitude higher in mass than any existing limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, we have demonstrated total noise approaching the standard quantum limit for the first time in an axion search.

astro-ph.CO

Ion irradiated YBa2Cu3O7 nano-meanders for superconducting single photon detectors

We report the fabrication of few hundred microns long, hundreds of nanometers wide and 30 nm thick meanders made from YBa2CU3O7. Thin films protected by a 8 nm-thick Ce02 cap layer have been patterned by high energy (a few tens of keV) oxygen ion irradiation through photoresist masks. DC and RF characterizations outline good superconducting properties of nano-meanders that could be used as Superconducting Single Photon Detectors (SSPD). By mean of a resonant method, their inductance, which mainly sets the maximum speed of these devices, has been measured on a wide range of temperature. It compares favorably with expected values calculated from the geometry of the meanders and the known London penetration depth in YBa2CU3O7.

cond-mat.supr-con