Searcharxiv⌕ Search

arXiv subjects

M. Martínez-Vara

Publications and source records attributed to M. Martínez-Vara.

25 records · Page 2Linked to original sources

Measurement of the ${}^{136}$Xe two-neutrino double beta decay half-life via direct background subtraction in NEXT

We report a measurement of the half-life of the ${}^{136}$Xe two-neutrino double beta decay performed with a novel direct background subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with ${}^{136}$Xe-enriched and ${}^{136}$Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of $2.34^{+0.80}_{-0.46}\textrm{(stat)}^{+0.30}_{-0.17}\textrm{(sys)}\times10^{21}~\textrm{yr}$ is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double beta decay searches.

nucl-ex↗

Ba$^{2+}$ ion trapping by organic submonolayer: towards an ultra-low background neutrinoless double beta decay detector

If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($ββ0ν$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay ${}^{136}\mathrm{Xe} \rightarrow {}^{136}$Ba$^{+2}+ 2 e + (2 ν)$ in a high pressure gas experiment, could lead to a virtually background free experiment. To identify these \Bapp, chemical sensors are being explored as a key tool by the NEXT collaboration . Although used in many fields, the application of such chemosensors to the field of particle physics is totally novel and requires experimental demonstration of their suitability in the ultra-dry environment of a xenon gas chamber. Here we use a combination of complementary surface science techniques to unambiguously show that Ba$^{+2}$ ions can be trapped (chelated) in vacuum by an organic molecule, the so-called fluorescent bicolour indicator (FBI) (one of the chemosensors developed by NEXT), immobilized on a surface. We unravel the ion capture mechanism once the molecules are immobilised on Au(111) surface and explain the origin of the emission fluorescence shift associated to the trapping of different ions. Moreover, we prove that chelation also takes place on a technologically relevant substrate, as such, demonstrating the feasibility of using FBI indicators as building blocks of a Ba$^{+2}$ detector.

hep-ex↗

The Dynamics of Ions on Phased Radio-frequency Carpets in High Pressure Gases and Application for Barium Tagging in Xenon Gas Time Projection Chambers

Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods for modeling RF ion transport at densities where dynamics are strongly influenced by buffer gas collisions. An analytic description of levitating and sweeping forces from phased arrays is obtained, then thermodynamic and kinetic principles are used to calculate ion loss rates in the presence of collisions. This methodology is validated against detailed microscopic SIMION simulations. We then explore a parameter space of special interest for neutrinoless double beta decay experiments: transport of barium ions in xenon at pressures from 1 to 10 bar. Our computations account for molecular ion formation and pressure dependent mobility as well as finite temperature effects. We discuss the challenges associated with achieving suitable operating conditions, which lie beyond the capabilities of existing devices, using presently available or near-future manufacturing techniques.

physics.ins-det↗

Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution

Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~5 when reconstructing electron-positron pairs in the $^{208}$Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV $e^-e^+$ pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.

physics.ins-det↗

Sensitivity of the NEXT experiment to Xe-124 double electron capture

Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture ($2νECEC$) has been predicted for a number of isotopes, but only observed in $^{78}$Kr, $^{130}$Ba and, recently, $^{124}$Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, $0νECEC$. Here we report on the current sensitivity of the NEXT-White detector to $^{124}$Xe $2νECEC$ and on the extrapolation to NEXT-100. Using simulated data for the $2νECEC$ signal and real data from NEXT-White operated with $^{124}$Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of $^{124}$Xe and for a 5-year run, a sensitivity to the $2νECEC$ half-life of $6 \times 10^{22}$ y (at 90% confidence level) or better can be reached.

hep-ex↗

Sensitivity of a tonne-scale NEXT detector for neutrinoless double beta decay searches

The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of neutrinoless double-beta decay decay better than 1E27 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond.

physics.ins-det↗

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm. We also see that the reflectance of PTFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance.

physics.ins-det↗