Searcharxiv⌕ Search

arXiv subjects

M. Martinez

Publications and source records attributed to M. Martinez.

At least 91 records · Page 5Linked to original sources

CUORE Sensitivity to $0νββ$ Decay

We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitivity. We consider various background levels and energy resolutions, and describe the influence of the data division in subsets with different background levels. If the background level and the energy resolution meet the expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of $2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of live time. Under the same conditions, the discovery sensitivity after $3$ months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr, respectively.

physics.ins-det↗

Bright 5 - 85 MeV Compton gamma-ray pulses from GeV laser-plasma accelerator and plasma mirror

We convert a GeV laser-plasma electron accelerator into a compact femtosecond-pulsed $γ$-ray source by inserting a $100 μ$m-thick glass plate $\sim3$ cm after the accelerator exit. With near-unity reliability, and requiring only crude alignment, this glass plasma mirror retro-reflected spent drive laser pulses (photon energy $\hbarω_L = 1.17$ eV) with $>50\%$ efficiency back onto trailing electrons (peak Lorentz factor $1000 < γ_e < 4400$), creating an optical undulator that generated $\sim10^8 γ$-ray photons with sub-mrad divergence, estimated peak brilliance $\sim10^{21}$ photons/s/mm$^2$/mrad$^2$/$0.1\%$ bandwidth and negligible bremsstrahlung background. The $γ$-ray photon energy $E_γ= 4γ_e^2 \hbarω_L$, inferred from the measured $γ_e$ on each shot, peaked from 5 to 85 MeV, spanning a range otherwise available with comparable brilliance only from large-scale GeV-linac-based high-intensity $γ$-ray sources.

physics.acc-ph↗

High-sensitivity Kinetic Inductance Detectors for CALDER

Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors allows simultaneous read-out of the light and heat signals and enables background suppression through particle identification. The Cryogenic wide- Area Light Detector with Excellent Resolution (CALDER) R&D already proved the potential of this technique using the phonon-mediated Kinetic Inductance Detectors (KIDs) approach. The first array prototype with 4 Aluminum KIDs on a 2 $\times$ 2 cm2 Silicon substrate showed a baseline resolution of 154 $\pm$ 7 eV RMS. Improving the design and the readout of the resonator, the next CALDER prototype featured an energy resolution of 82 $\pm$ 4 eV, by sampling the same substrate with a single Aluminum KID.

physics.ins-det↗

Viscous anisotropic hydrodynamics for the Gubser flow

In this work we describe the dynamics of a highly anisotropic system undergoing boost-invariant longitudinal and azimuthally symmetric radial expansion (Gubser flow) for arbitrary shear viscosity to entropy density ratio. We derive the equations of motion of dissipative anisotropic hydrodynamics by applying to this situation the moments method recently derived by Molnár et al. (MNR) [1,2], based on an expansion around an arbitrary anisotropic one-particle distribution function. One requires an additional evolution equation in order to close the conservation laws. This is achieved by selecting the relaxation equation for the longitudinal pressure with a suitable Landau matching condition. As a result one obtains two coupled differential equations for the energy density and the longitudinal pressure which respect the $SO(3)_q\otimes SO(1,1)\otimes Z_2$ symmetry of the Gubser flow in the deSitter space. These equations are solved numerically and compared with the predictions of the recently found exact solution of the relaxation-time-approximation Boltzmann equation subject to the same flow. We also compare our numerical results with other fluid dynamical models. We observe that the MNR description of anisotropic fluid dynamics reproduces the space-time evolution of the system than all other currently known hydrodynamical approaches.

nucl-th↗

Anisotropic fluid dynamics for Gubser flow

Exploring a variety of closing schemes to the infinite hierarchy of momentum moments of the exactly solvable Boltzmann equation for systems undergoing Gubser flow, we study the precision with which the resulting hydrodynamic equations reproduce the exact evolution of hydrodynamic moments of the distribution function. We find that anisotropic hydrodynamics, obtained by ex- panding the distribution function around a dynamically evolving locally anisotropic background whose evolution is matched to exactly reproduce the macroscopic pressure anisotropy caused by the different longitudinal and transverse expansion rates in Gubser flow, provides the most accurate macroscopic description of the microscopic kinetic evolution. This confirms a similar earlier finding for Bjorken flow [Molnár, Niemi and Rischke, Phys. Rev. D 94, 125003 (2016)]. We explain the physics behind this optimal matching procedure and show that one can efficiently correct for a non- optimized matching choice by adding a residual shear stress to the energy-momentum tensor whose evolution is again determined by the Boltzmann equation. Additional insights to guide the optimal choice of a macroscopic anisotropic hydrodynamic framework for strongly-coupled systems that do not admit a microscopic kinetic description are reported.

nucl-th↗

Measurement of the Two-Neutrino Double Beta Decay Half-life of $^{130}$Te with the CUORE-0 Experiment

We report on the measurement of the two-neutrino double beta decay half-life of $^{130}$Te with the CUORE-0 detector. From an exposure of 33.4 kg$\cdot$y of TeO$_2$, the half-life is determined to be $T_{1/2}^{2ν}$ = [8.2 $\pm$ 0.2 (stat.) $\pm$ 0.6 (syst.)] $\times$ 10$^{20}$y. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the $^{130}$Te neutrinoless double beta decay region of interest.

nucl-ex↗

High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out

The development of wide-area cryogenic light detectors with good energy resolution is one of the priorities of next generation bolometric experiments searching for rare interactions, as the simultaneous read-out of the light and heat signals enables background suppression through particle identification. Among the proposed technological approaches for the phonon sensor, the naturally-multiplexed Kinetic Inductance Detectors (KIDs) stand out for their excellent intrinsic energy resolution and reproducibility. To satisfy the large surface requirement (several cm$^2$) KIDs are deposited on an insulating substrate that converts the impinging photons into phonons. A fraction of phonons is absorbed by the KID, producing a signal proportional to the energy of the original photons. The potential of this technique was proved by the CALDER project, that reached a baseline resolution of 154$\pm$7 eV RMS by sampling a 2$\times$2 cm$^2$ Silicon substrate with 4 Aluminum KIDs. In this paper we present a prototype of Aluminum KID with improved geometry and quality factor. The design improvement, as well as the combined analysis of amplitude and phase signals, allowed to reach a baseline resolution of 82$\pm$4 eV by sampling the same substrate with a single Aluminum KID.

physics.ins-det↗

The CUORE and CUORE-0 experiments at LNGS

The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the largest 130Te bolometric setup ever operated. CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from 2013 to 2015. The final CUORE-0 analysis on 0ν\b{eta}\b{eta} and the corresponding detector performance are presented. The present status of the CUORE experiment, now in its final construction and commissioning phase, are discussed. The results from assembly of the detector and the commissioning of the cryostat are reported.

physics.ins-det↗

Nonlinear dynamics from the relativistic Boltzmann equation in the Friedmann-Lemaître-Robertson-Walker spacetime

The dissipative dynamics of an expanding massless gas with constant cross section in a spatially flat Friedmann-Lemaître-Robertson-Walker (FLRW) universe is studied. The mathematical problem of solving the full nonlinear relativistic Boltzmann equation is recast into an infinite set of nonlinear ordinary differential equations for the moments of the one-particle distribution function. Momentum-space resolution is determined by the number of non-hydrodynamic modes included in the moment hierarchy, i.e., by the truncation order. We show that in the FLRW spacetime the non-hydrodynamic modes decouple completely from the hydrodynamic degrees of freedom. This results in the system flowing as an ideal fluid while at the same time producing entropy. The solutions to the nonlinear Boltzmann equation exhibit transient tails of the distribution function with nontrivial momentum dependence. The evolution of this tail is not correctly captured by the relaxation time approximation nor by the linearized Boltzmann equation. However, the latter probes additional high-momentum details unresolved by the relaxation time approximation. While the expansion of the FLRW spacetime is slow enough for the system to move towards (and not away from) local thermal equilibrium, it is not sufficiently slow for the system to actually ever reach complete local equilibrium. Equilibration is fastest in the relaxation time approximation, followed, in turn, by kinetic evolution with a linearized and a fully nonlinear Boltzmann collision term.

hep-ph↗

Assessment of backgrounds of the ANAIS experiment for dark matter direct detection

A large effort has been carried out to characterize the background of sodium iodide crystals within the ANAIS (Annual modulation with NaI Scintillators) project. In this paper, the background models developed for three 12.5-kg NaI(Tl) scintillators produced by Alpha Spectra Inc. and operated at the Canfranc Underground Laboratory are presented together with an evaluation of the background prospects for the full experiment. Measured spectra from threshold to high energy in different conditions are well described by the models based on quantified activities. At the region of interest, crystal bulk contamination is the dominant background source. Contributions from 210Pb, 40K, 22Na and 3H are the most relevant. Those from 40K and 22Na could be efficiently suppressed thanks to anticoincidence operation in a crystals matrix or inside a Liquid Scintillator Veto (LSV), while that from 210Pb has been reduced by improving crystal production methods and 3H production could be reduced by shielding against cosmic rays during production. Assuming the activities of the last characterized detector, for nine crystals with a total mass of 112.5 kg the expected background rate is 2.5 counts/(keV kg d) in the region from 1 to 4 keV, which could be reduced at 1.4 counts/(keV kg d) by using a LSV.

astro-ph.IM↗

CUORE-0 detector: design, construction and operation

The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.

physics.ins-det↗

First array of enriched Zn$^{82}$Se bolometers to search for double beta decay

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in $^{82}$Se, the Zn$^{82}$Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn$^{82}$Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.

physics.ins-det↗

Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in $^{130}$Te with CUORE-0

We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive $0νββ$ decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final $0νββ$ decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized $0νββ$ decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the $0νββ$ decay half-life limits previously reported for CUORE-0, $T^{0ν}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino limit, $T^{0ν}_{1/2}>4.0\times10^{24}$ yr.

nucl-ex↗

New application of superconductors: high sensitivity cryogenic light detectors

In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs), that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results obtained by the CALDER collaboration with 2x2 cm2 substrates sampled by 1 or 4 Aluminum KIDs. We show that the performances of the first prototypes are already competitive with those of other commonly used light detectors, and we discuss the strategies for a further improvement.

physics.ins-det↗

Multi-Wavelength Observations of the Blazar 1ES 1011+496 in Spring 2008

The BL Lac object 1ES 1011+496 was discovered at Very High Energy gamma-rays by MAGIC in spring 2007. Before that the source was little studied in different wavelengths. Therefore a multi-wavelength (MWL) campaign was organized in spring 2008. Along MAGIC, the MWL campaign included the Metsahovi radio observatory, Bell and KVA optical telescopes and the Swift and AGILE satellites. MAGIC observations span from March to May, 2008 for a total of 27.9 hours, of which 19.4 hours remained after quality cuts. The light curve showed no significant variability. The differential VHE spectrum could be described with a power-law function. Both results were similar to those obtained during the discovery. Swift XRT observations revealed an X-ray flare, characterized by a harder when brighter trend, as is typical for high synchrotron peak BL Lac objects (HBL). Strong optical variability was found during the campaign, but no conclusion on the connection between the optical and VHE gamma-ray bands could be drawn. The contemporaneous SED shows a synchrotron dominated source, unlike concluded in previous work based on nonsimultaneous data, and is well described by a standard one zone synchrotron self Compton model. We also performed a study on the source classification. While the optical and X-ray data taken during our campaign show typical characteristics of an HBL, we suggest, based on archival data, that 1ES 1011+496 is actually a borderline case between intermediate and high synchrotron peak frequency BL Lac objects.

astro-ph.HE↗

Search for VHE gamma-ray emission from Geminga pulsar and nebula with the MAGIC telescopes

The Geminga pulsar, one of the brighest gamma-ray sources, is a promising candidate for emission of very-high-energy (VHE > 100 GeV) pulsed gamma rays. Also, detection of a large nebula have been claimed by water Cherenkov instruments. We performed deep observations of Geminga with the MAGIC telescopes, yielding 63 hours of good-quality data, and searched for emission from the pulsar and pulsar wind nebula. We did not find any significant detection, and derived 95% confidence level upper limits. The resulting upper limits of 5.3 x 10^{-13} TeV cm^{-2} s^{-1} for the Geminga pulsar and 3.5 x 10^{-12} TeV cm^{-2} s^{-1} for the surrounding nebula at 50 GeV are the most constraining ones obtained so far at VHE. To complement the VHE observations, we also analyzed 5 years of Fermi-LAT data from Geminga, finding that the sub-exponential cut-off is preferred over the exponential cut-off that has been typically used in the literature. We also find that, above 10 GeV, the gamma-ray spectra from Geminga can be described with a power law with index softer than 5. The extrapolation of the power-law Fermi-LAT pulsed spectra to VHE goes well below the MAGIC upper limits, indicating that the detection of pulsed emission from Geminga with the current generation of Cherenkov telescopes is very difficult.

astro-ph.HE↗

CALDER: cryogenic light detector for rare events search

The CALDER project aims at developing cryogenic light detectors with high sensitivity to UV and visible light, to be used for particle tagging in massive bolometers. Indeed the sensitivity of CUORE can be increased by a factor of 3, thanks to the reduction of the $α$-background, obtained by detecting the Cherenkov light (100 eV) emitted by $β/γ$ events. Currently used light detectors have not the features required to address this task, so we decided to develop a new light detector using Kinetic Inductance Detector as a sensor. This approach is very challenging and requires an intensive R$\&$D to be satisfied. The first results of this activity are shown in the following.

physics.ins-det↗

Analytic solution of the Boltzmann equation in an expanding system

For a massless gas with constant cross section in a homogeneous, isotropically expanding spacetime we reformulate the relativistic Boltzmann equation as a set of non-linear coupled moment equations. For a particular initial condition this set can be solved exactly, yielding the first analytical solution of the Boltzmann equation for an expanding system. The non-equilibrium behavior of this relativistic gas can be mapped onto that of a homogeneous, static non-relativistic gas of Maxwell molecules.

hep-ph↗