SearcharxivSearch

arXiv subjects

M. Meier

Publications and source records attributed to M. Meier.

7 recordsLinked to original sources

Sub-keV energy calibration of CONUS+ via 71Ge M-shell neutron activation

The CONUS+ experiment has recently reported the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) of reactor antineutrinos on germanium nuclei and is now entering a precision phase. The dominant uncertainty in the first measurement was the energy scale, which contributed 14% to the uncertainty of the prediction of the combined signal. We present a dedicated neutron activation campaign in which one of the new 2.4 kg CONUS+ germanium detectors was irradiated with a strong 241AmBe source, demonstrating that a contribution below 4% to the uncertainty of signal prediction is achievable. For the first time, the 71Ge M-shell X-ray line was clearly resolved at (158.7+-1.4) eVee, validating the CONUS+ energy reconstruction down to the detection threshold. This validation includes the understanding of the energy scale, the energy resolution, the trigger efficiency, and the correct separation of physical from noise events. These results establish the foundation for a future activation campaign at the Kernkraftwerk Leibstadt reactor site, strengthening the CONUS+ energy calibration and extending its sensitivity to precision CEvNS and beyond Standard Model physics measurements.

hep-ex

Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment

We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm, inside a large magnetically shielded room (MSR). We have assembled this system and characerized its performances with a mapping robot. The apparatus is able to generate a 1 $\mu$ T vertical field with a relative root mean square deviation $\sigma$ ($B_z$)/$B_z$ = 3 $\times$ $10^{-5}$ over the volume of interest, a cylinder of radius 40 cm and height 30 cm. This level of uniformity overcomes the n2EDM requirements, allowing a measurement of the neutron Electric Dipole Moment with a sensitivity better than 1 $\times$ $10^{-27}$ ecm.

physics.ins-det

The Pioneer Venus Orbiter Catalog of Gamma-Ray Bursts

The Pioneer Venus Orbiter (PVO) Gamma-ray burst experiment detected 318 gamma-ray bursts over about 14 years between 1978 and 1992 with near $4\pi$ coverage. This data set complements BATSE by determining the properties of the brightest gamma-ray bursts. PVO places a constrains on the slope of the bright end of the Log N-Log P distribution. The slope is -1.52$\pm 0.15$.

astro-ph.HE

Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment

The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $\beta$-decay endpoint region with a sensitivity on $m_\nu$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $\beta$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6$\,$keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $\beta$-electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the \linebreak energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique. We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% T$_2$ gas mixture at 30$\,$K, as used in the first KATRIN neutrino mass analyses, as well as a D$_2$ gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $\sigma(m_\nu^2)<10^{-2}\,\mathrm{eV}^2$ [arXiv:2101.05253] in the KATRIN neutrino-mass measurement to a subdominant level.

physics.ins-det

The design of the n2EDM experiment

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.

physics.ins-det

An ultracold neutron storage bottle for UCN density measurements

We have developed a storage bottle for ultracold neutrons (UCN) in order to measure the UCN density at the beamports of the Paul Scherrer Institute's (PSI) UCN source. This paper describes the design, construction and commissioning of the robust and mobile storage bottle with a volume comparable to typical storage experiments 32 liter e.g. searching for an electric dipole moment of the neutron.

physics.ins-det

Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magnetic field are attenuated by factors of 5 to 50 at a bandwidth from $10^{-3}$ Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the nEDM measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.

physics.ins-det