Searcharxiv⌕ Search

arXiv subjects

M. N'Diaye

Publications and source records attributed to M. N'Diaye.

27 records · Page 2Linked to original sources

On-sky compensation of non-common path aberrations with the ZELDA wavefront sensor in VLT/SPHERE

Circumstellar environments are now routinely observed by dedicated high-contrast imagers on large, ground-based observatories. These facilities combine extreme adaptive optics and coronagraphy to achieve unprecedented sensitivities for exoplanet detection and spectral characterization. However, non-common path aberrations (NCPA) in these coronagraphic systems represent a critical limitation for the detection of giant planets with a contrast lower than a few $10^{-6}$ at very small separations ($<$0.3$^{\prime\prime}$) from their host star. In 2013 we proposed ZELDA, a Zernike wavefront sensor to measure these residual quasi-static phase aberrations and a prototype was installed in SPHERE, the exoplanet imager for the VLT. In 2016, we demonstrated the ability of our sensor to provide a nanometric calibration and compensation for these aberrations on an internal source in the instrument, resulting in a contrast gain of 10 at 0.2$^{\prime\prime}$ in coronagraphic images. However, initial on-sky tests in 2017 did not show a tangible gain in contrast when calibrating the NCPA internally and then applying the correction on sky. In this communication, we present recent on-sky measurements to demonstrate the potential of our sensor for the NCPA compensation during observations and quantify the contrast gain in coronagraphic data.

astro-ph.IM↗

Active correction of aperture discontinuities - optimized stroke minimization I: a new adaptive interaction matrix algorithm

Future searches for biomarkers on habitable exoplanets will rely on telescope instruments that achieve extremely high contrast at small planet-to-star angular separations. Coronagraphy is a promising starlight suppression technique, providing excellent contrast and throughput for off-axis sources on clear apertures. However, the complexity of space- and ground-based telescope apertures goes on increasing over time, owing to the combination of primary mirror segmentation, secondary mirror, and support structures. These discontinuities in the telescope aperture limit the coronagraph performance. In this paper, we present ACAD-OSM, a novel active method to correct for the diffractive effects of aperture discontinuities in the final image plane of a coronagraph. Active methods use one or several deformable mirrors that are controlled with an interaction matrix to correct for the aberrations in the pupil. However, they are often limited by the amount of aberrations introduced by aperture discontinuities. This algorithm relies on the recalibration of the interaction matrix during the correction process to overcome this limitation. We first describe the ACAD-OSM technique and compare it to the previous active methods for the correction of aperture discontinuities. We then show its performance in terms of contrast and off-axis throughput for static aperture discontinuities (segmentation, struts) and for some aberrations evolving over the life of the instrument (residual phase aberrations, artifacts in the aperture, misalignments in the coronagraph design). This technique can now obtain the earth-like planet detection threshold of 10^(-10) contrast on any given aperture over at least a 10% spectral bandwidth, with several coronagraph designs.

astro-ph.IM↗

First scattered-light images of the gas-rich debris disk around 49 Ceti

We present the first scattered-light images of the debris disk around 49 ceti, a ~40 Myr A1 main sequence star at 59 pc, famous for hosting two massive dust belts as well as large quantities of atomic and molecular gas. The outer disk is revealed in reprocessed archival Hubble Space Telescope NICMOS F110W images, as well as new coronagraphic H band images from the Very Large Telescope SPHERE instrument. The disk extends from 1.1" (65 AU) to 4.6" (250 AU), and is seen at an inclination of 73degr, which refines previous measurements at lower angular resolution. We also report no companion detection larger than 3 M_Jup at projected separations beyond 20 AU from the star (0.34"). Comparison between the F110W and H-band images is consistent with a grey color of 49 ceti's dust, indicating grains larger than >2microns. Our photometric measurements indicate a scattering efficiency / infrared excess ratio of 0.2-0.4, relatively low compared to other characterized debris disks. We find that 49 ceti presents morphological and scattering properties very similar to the gas-rich HD 131835 system. From our constraint on the disk inclination we find that the atomic gas previously detected in absorption must extend to the inner disk, and that the latter must be depleted of CO gas. Building on previous studies, we propose a schematic view of the system describing the dust and gas structure around 49 ceti and hypothetic scenarios for the gas nature and origin.

astro-ph.EP↗

Calibration of quasi-static aberrations in exoplanet direct-imaging instruments with a Zernike phase-mask sensor. II. Concept validation with ZELDA on VLT/SPHERE

Warm or massive gas giant planets, brown dwarfs, and debris disks around nearby stars are now routinely observed by dedicated high-contrast imaging instruments on large, ground-based observatories. These facilities include extreme adaptive optics (ExAO) and state-of-the-art coronagraphy to achieve unprecedented sensitivities for exoplanet detection and spectral characterization. However, differential aberrations between the ExAO sensing path and the science path represent a critical limitation for the detection of giant planets with a contrast lower than a few $10^{-6}$ at very small separations (<0.3\as) from their host star. In our previous work, we proposed a wavefront sensor based on Zernike phase contrast methods to circumvent this issue and measure these quasi-static aberrations at a nanometric level. We present the design, manufacturing and testing of ZELDA, a prototype that was installed on VLT/SPHERE during its reintegration in Chile. Using the internal light source of the instrument, we performed measurements in the presence of Zernike or Fourier modes introduced with the deformable mirror. Our experimental and simulation results are consistent, confirming the ability of our sensor to measure small aberrations (<50 nm rms) with nanometric accuracy. We then corrected the long-lived non-common path aberrations in SPHERE based on ZELDA measurements. We estimated a contrast gain of 10 in the coronagraphic image at 0.2\as, reaching the raw contrast limit set by the coronagraph in the instrument. The simplicity of the design and its phase reconstruction algorithm makes ZELDA an excellent candidate for the on-line measurements of quasi-static aberrations during the observations. The implementation of a ZELDA-based sensing path on the current and future facilities (ELTs, future space missions) could ease the observation of the cold gaseous or massive rocky planets around nearby stars.

astro-ph.EP↗

Laboratory validation of the dual-zone phase mask coronagraph in broadband light at the high-contrast imaging THD-testbed

Specific high contrast imaging instruments are mandatory to characterize circumstellar disks and exoplanets around nearby stars. Coronagraphs are commonly used in these facilities to reject the diffracted light of an observed star and enable the direct imaging and spectroscopy of its circumstellar environment. One important property of the coronagraph is to be able to work in broadband light. Among several proposed coronagraphs, the dual-zone phase mask coronagraph is a promising solution for starlight rejection in broadband light. In this paper, we perform the first validation of this concept in laboratory. First, we recall the principle of the dual-zone phase mask coronagraph. Then, we describe the high-contrast imaging THD testbed, the manufacturing of the components and the quality-control procedures. Finally, we study the sensitivity of our coronagraph to low-order aberrations (inner working angle and defocus) and estimate its contrast performance. Our experimental broadband light results are compared with numerical simulations to check agreement with the performance predictions. With the manufactured prototype and using a dark hole technique based on the self-coherent camera, we obtain contrast levels down to $2\,10^{-8}$ between 5 and 17$\,λ_0/D$ in monochromatic light (640 nm). We also reach contrast levels of $4\,10^{-8}$ between 7 and 17$λ_0/D$ in broadband ($λ_0=675$ nm, $Δλ=250$ nm and $Δλ/ λ_0 = 40$ %), which demonstrates the excellent chromatic performance of the dual-zone phase mask coronagraph. The performance reached by the dual-zone phase mask coronagraph is promising for future high-contrast imaging instruments that aim at detecting and spectrally characterizing old or light gaseous planets.

astro-ph.IM↗

Apodization in high-contrast long-slit spectroscopy. II. Concept validation and first on-sky results with VLT/SPHERE

Spectral characterization of young, giant exoplanets detected by direct imaging is one of the tasks of the new generation of high-contrast imagers. For this purpose, the VLT/SPHERE instrument includes a unique long-slit spectroscopy (LSS) mode coupled with Lyot coronagraphy in its infrared dual-band imager and spectrograph (IRDIS). The performance of this mode is intrinsically limited by the use of a non-optimal coronagraph, but in a previous work we demonstrated that it could be significantly improved at small inner-working angles using the stop-less Lyot coronagraph (SLLC). We now present the development, testing, and validation of the first SLLC prototype for VLT/SPHERE. Based on the transmission profile previously proposed, the prototype was manufactured using microdots technology and was installed inside the instrument in 2014. The transmission measurements agree well with the specifications, except in the very low transmissions (<5% in amplitude). The performance of the SLLC is tested in both imaging and spectroscopy using data acquired on the internal source. In imaging, we obtain a raw contrast gain of a factor 10 at 0.3" and 5 at 0.5" with the SLLC. Using data acquired with a focal-plane mask, we also demonstrate that no Lyot stop is required to reach the full performance, which validates the SLLC concept. Comparison with a realistic simulation model shows that we are currently limited by the internal phase aberrations of SPHERE. In spectroscopy, we obtain a gain of ~1 mag in a limited range of angular separations. Simulations show that although the main limitation comes from phase errors, the performance in the non-SLLC case is very close to the ultimate limit of the LSS mode. Finally, we obtain the very first on-sky data with the SLLC, which appear extremely promising for the future scientific exploitation of an apodized LSS mode in SPHERE.

astro-ph.IM↗

Apodization in high-contrast long-slit spectroscopy. Closer, deeper, fainter, cooler

The spectroscopy of faint planetary-mass companions to nearby stars is one of the main challenges that new-generation high-contrast spectro-imagers are going to face. In a previous work we presented a long slit coronagraph (LSC), for which the presence of a slit in the coronagraphic focal plane induces a complex distribution of energy in the Lyot pupil-plane that cannot be easily masked with a binary Lyot stop. To alleviate this concern, we propose to use a pupil apodization to suppress diffraction, creating an apodized long slit coronagraph (ALSC). After describing how the apodization is optimized, we demonstrate its advantages with respect to the CLC in the context of SPHERE/IRDIS long slit spectroscopy (LSS) mode at low-resolution with a 0.12" slit and 0.18" coronagraphic mask. We perform different sets of simulations with and without aberrations, and with and without a slit to demonstrate that the apodization is a more appropriate concept for LSS, at the expense of a significantly reduced throughput (37%) compared to the LSC. Then we perform detailed end-to-end simulations of the LSC and the ALSC that include realistic levels of aberrations to obtain datasets representing 1h of integration time on stars of spectral types A0 to M0 located at 10 pc. We insert spectra of planetary companions at different effective temperatures (Teff) and surface gravities (log g) into the data at angular separations of 0.3" to 1.5" and with contrast ratios from 6 to 18 mag. Using the SD method to subtract the speckles, we show that the ALSC brings a gain in sensitivity of up to 3 mag at 0.3" with respect to the LSC, which leads to a much better spectral extraction below 0.5". In terms of Teff, we demonstrate that at small angular separations the limit with the ALSC is always lower by at least 100K, inducing an increase of sensitivity of a factor up to 1.8 in objects' masses at young ages. [Abridged]

astro-ph.IM↗

Calibration of quasi-static aberrations in exoplanet direct-imaging instruments with a Zernike phase-mask sensor

Context. Several exoplanet direct imaging instruments will soon be in operation. They use an extreme adaptive optics (XAO) system to correct the atmospheric turbulence and provide a highly-corrected beam to a near-infrared (NIR) coronagraph for starlight suppression. The performance of the coronagraph is however limited by the non-common path aberrations (NCPA) due to the differential wavefront errors existing between the visible XAO sensing path and the NIR science path, leading to residual speckles in the coronagraphic image. Aims. Several approaches have been developed in the past few years to accurately calibrate the NCPA, correct the quasi-static speckles and allow the observation of exoplanets at least 1e6 fainter than their host star. We propose an approach based on the Zernike phase-contrast method for the measurements of the NCPA between the optical path seen by the visible XAO wavefront sensor and that seen by the near-IR coronagraph. Methods. This approach uses a focal plane phase mask of size λ/D, where λ and D denote the wavelength and the telescope aperture diameter, respectively, to measure the quasi-static aberrations in the upstream pupil plane by encoding them into intensity variations in the downstream pupil image. We develop a rigorous formalism, leading to highly accurate measurement of the NCPA, in a quasi-linear way during the observation. Results. For a static phase map of standard deviation 44 nm rms at λ = 1.625 μm (0.026 λ), we estimate a possible reduction of the chromatic NCPA by a factor ranging from 3 to 10 in the presence of AO residuals compared with the expected performance of a typical current-generation system. This would allow a reduction of the level of quasi-static speckles in the detected images by a factor 10 to 100 hence, correspondingly improving the capacity to observe exoplanets.

astro-ph.IM↗

Improved achromatization of phase mask coronagraphs using colored apodization

For direct imaging of exoplanets, a stellar coronagraph helps to remove the image of an observed bright star by attenuating the diffraction effects caused by the telescope aperture of diameter D. The Dual Zone Phase Mask (DZPM) coronagraph constitutes a promising concept since it theoretically offers a small inner working angle (IWA \sim λ_0/D), good achromaticity and high starlight rejection, typically reaching a 1e6 contrast at 5 λ_0/D from the star over a spectral bandwidth Δλ/λ_0 of 25% (similar to H-band). This last value proves to be encouraging for broadband imaging of young and warm Jupiter-like planets. Contrast levels higher than 1e6 are however required for the observation of older and/or less massive companions over a finite spectral bandwidth. An achromatization improvement of the DZPM coronagraph is therefore mandatory to reach such performance. In its design, the DZPM coronagraph uses a grey (or achromatic) apodization. We propose to replace it by a colored apodization to increase the performance of this coronagraphic system over a large spectral range. This innovative concept, called Colored Apodizer Phase Mask (CAPM) coronagraph, is defined with some design parameters optimized to reach the best contrast in the exoplanet search area. Once this done, we study the performance of the CAPM coronagraph in the presence of different errors to evaluate the sensitivity of our concept. A 2.5 mag contrast gain is estimated from the performance provided by the CAPM coronagraph with respect to that of the DZPM coronagraph. A 2.2e-8 intensity level at 5 λ_0/D separation is then theoretically achieved with the CAPM coronagraph in the presence of a clear circular aperture and a 25% bandwidth. In addition, our studies show that our concept is less sensitive to low than high-order aberrations for a given value of rms wavefront errors.

astro-ph.IM↗