SearcharxivSearch

arXiv subjects

M. Oliver

Publications and source records attributed to M. Oliver.

7 recordsLinked to original sources

Setup for meV-resolution inelastic X-ray scattering measurements at the Matter in Extreme Conditions Endstation at the LCLS

We describe a setup for performing inelastic X-ray scattering measurements at the Matter in Extreme Conditions (MEC) endstation of the Linac Coherent Light Source (LCLS). This technique is capable of performing high-, meV-resolution measurements of dynamic ion features in both crystalline and non-crystalline materials. A four-bounce silicon (533) monochromator was used in conjunction with three silicon (533) diced crystal analyzers to provide an energy resolution of ~50 meV over a range of ~500 meV in single shot measurements. In addition to the instrument resolution function, we demonstrate the measurement of longitudinal acoustic phonon modes in polycrystalline diamond. Furthermore, this setup may be combined with the high intensity laser drivers available at MEC to create warm dense matter, and subsequently measure ion acoustic modes.

physics.ins-det

A Radial Time Projection Chamber for $α$ detection in CLAS at JLab

A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and coherent meson production off $^4$He. In such processes, the $^4$He nucleus remains intact in the final state, however the CEBAF Large Acceptance Spectrometer (CLAS) cannot track the low energy $α$ particles. In 2009, we carried out measurements using the CLAS spectrometer supplemented by the RTPC positioned directly around a gaseous $^4$He target, allowing a detection threshold as low as 12$\sim$MeV for $^4$He. This article discusses the design, principle of operation, calibration methods and the performances of this RTPC.

physics.ins-det

Identification and mitigation of narrow spectral artifacts that degrade searches for persistent gravitational waves in the first two observing runs of Advanced LIGO

Searches are under way in Advanced LIGO and Virgo data for persistent gravitational waves from continuous sources, e.g. rapidly rotating galactic neutron stars, and stochastic sources, e.g. relic gravitational waves from the Big Bang or superposition of distant astrophysical events such as mergers of black holes or neutron stars. These searches can be degraded by the presence of narrow spectral artifacts (lines) due to instrumental or environmental disturbances. We describe a variety of methods used for finding, identifying and mitigating these artifacts, illustrated with particular examples. Results are provided in the form of lists of line artifacts that can safely be treated as non-astrophysical. Such lists are used to improve the efficiencies and sensitivities of continuous and stochastic gravitational wave searches by allowing vetoes of false outliers and permitting data cleaning.

astro-ph.IM

Combination of two Gas Electron Multipliers and a Micromegas as gain elements for a time projection chamber

We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space charge in the drift volume of such detectors in order to eliminate the standard gating grid and its resultant dead time, while preserving good tracking and particle identification performance. We measured the positive ion back-flow and energy resolution at various element gains and electric fields, using a variety of gases, and additionally studied crosstalk effects and discharge rates. At a gain of 2000, this configuration achieves an ion back-flow below 0.4% and an energy resolution better than $σ/\text{E}=12\%$ for $^{55}$Fe X-rays.

physics.ins-det

Calibration of Time Of Flight Detectors Using Laser-driven Neutron Source

Calibration of three scintillators (EJ232Q, BC422Q and EJ410) in a time-of-flight (TOF) arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors are shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

physics.ins-det

IEEE 802.11ah: The Wi-Fi Approach for M2M Communications

M2M communications are projected to be one of the fastest growing technology segments of the IT sector in the next years. Sensor and actuator networks connect communication machines and devices so that they automatically transmit information, serving the growing demand for environmental data acquisition. IEEE 802.11ah Task Group addresses the creation of a new standard for giving response to the particular requirements of this type of networks: large number of power-constrained stations, long transmission range, small and infrequent data messages, low data-rates and non-critical delay. This article explores the key features of this new standard under development, especially those related to the reduction of energy consumption in the MAC Layer. In this direction, a performance assessment of IEEE 802.11ah in four typical M2M scenarios has been performed.

cs.NI

Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers

A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C6+, O8+, etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented.

physics.plasm-ph