SearcharxivSearch

arXiv subjects

M. Otani

Publications and source records attributed to M. Otani.

At least 19 recordsLinked to original sources

A diagnostic system of 5.7 keV muon beam for muon accelerator

Realization of a low-emittance muon beam through the acceleration of keV-scale muons requires the injection of a suitably matched beam into an accelerator, since beam mismatch can lead to emittance growth and reduced acceleration efficiency. In one such scheme, muons are first thermalized to room temperature and then injected into a linear accelerator. Non-destructive diagnostics are challenging because of the low energy and low intensity. We developed a compact low-energy muon diagnostic system compatible with the accelerator under construction at J-PARC. The system is designed to evaluate beam conditions required for precise tuning prior to acceleration. Commissioning with low-energy muon sources shows the system's capability to identify low-energy muon signals and measure beam profiles.

physics.acc-ph

Acceleration of positive muons by a radio-frequency cavity

Acceleration of positive muons from thermal energy to $100~$keV has been demonstrated. Thermal muons were generated by resonant multi-photon ionization of muonium atoms emitted from a sheet of laser-ablated aerogel. The thermal muons were first electrostatically accelerated to $5.7~$keV, followed by further acceleration to 100 keV using a radio-frequency quadrupole. The transverse normalized emittance of the accelerated muons in the horizontal and vertical planes were $0.85 \pm 0.25 ~\rm{(stat.)}~^{+0.22}_{-0.13} ~\rm{(syst.)}~π~$mm$\cdot$mrad and $0.32\pm 0.03~\rm{(stat.)} ^{+0.05}_{-0.02} ~\rm{(syst.)}~π~$mm$\cdot$mrad, respectively. The measured emittance values demonstrated phase space reduction by a factor of $2.0\times 10^2$ (horizontal) and $4.1\times 10^2$ (vertical) allowing good acceleration efficiency. These results pave the way to realize the first-ever muon accelerator for a variety of applications in particle physics, material science, and other fields.

physics.acc-ph

First muon acceleration and muon linear accelerator for measuring the muon anomalous magnetic moment and electric dipole moment

Muon acceleration using a radio-frequency accelerator was recently demonstrated for the first time. Measurement of the muon anomalous magnetic moment and electric dipole moment at Japan Proton Accelerator Research Complex is the first experiment using accelerated muon beams, and construction will begin soon. The radio-frequency accelerator used in the experiment and the first muon acceleration are described in this paper.

physics.acc-ph

Study of muonium emission from laser-ablated silica aerogel

The emission of muonium ($μ^+e^-$) atoms into vacuum from silica aerogel with laser ablation on its surface was studied with various ablation structures at room temperature using the subsurface muon beams at TRIUMF and Japan Proton Accelerator Research Complex (J-PARC). Laser ablation was applied to produce holes or grooves with typical dimensions of a few hundred $μ$m to a few mm, except for some extreme conditions. The measured emission rate tends to be higher for larger fractions of ablation opening and for shallower depths. More than a few ablation structures reach the emission rates similar to the highest achieved in the past measurements. The emission rate is found to be stable at least for a couple of days. Measurements of spin precession amplitudes for the produced muonium atoms and remaining muons in a magnetic field determine a muonium formation fraction of $(65.5 \pm 1.8)$%. The precession of the polarized muonium atoms is also observed clearly in vacuum. A projection of the emission rates measured at TRIUMF to the corresponding rates at J-PARC is demonstrated taking the different beam condition into account reasonably.

physics.ins-det

Compact buncher cavity for muons accelerated by a radio-frequency quadrupole

A buncher cavity has been developed for the muons accelerated by a radio-frequency quadrupole linac (RFQ). The buncher cavity is designed for $β=v/c=0.04$ at an operational frequency of 324 MHz. It employs a double-gap structure operated in the TEM mode for the required effective voltage with compact dimensions, in order to account for the limited space of the experiment. The measured resonant frequency and unloaded quality factor are 323.95 MHz and $3.06\times10^3$, respectively. The buncher cavity was successfully operated for longitudinal bunch size measurement of the muons accelerated by the RFQ.

physics.acc-ph

A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment

This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_μ$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.

physics.ins-det

First muon acceleration using a radio frequency accelerator

Muons have been accelerated by using a radio frequency accelerator for the first time. Negative muonium atoms (Mu$^-$), which are bound states of positive muons ($μ^+$) and two electrons, are generated from $μ^+$'s through the electron capture process in an aluminum degrader. The generated Mu$^-$'s are initially electrostatically accelerated and injected into a radio frequency quadrupole linac (RFQ). In the RFQ, the Mu$^-$'s are accelerated to 89 keV. The accelerated Mu$^-$'s are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.

physics.acc-ph

Search for double-beta decay of 136Xe to excited states of 136Ba with the KamLAND-Zen experiment

A search for double-beta decays of 136Xe to excited states of 136Ba has been performed with the first phase data set of the KamLAND-Zen experiment. The 0+1, 2+1 and 2+2 transitions of 0ν\{beta}\{beta} decay were evaluated in an exposure of 89.5kg-yr of 136Xe, while the same transitions of 2ν\{beta}\{beta} decay were evaluated in an exposure of 61.8kg-yr. No excess over background was found for all decay modes. The lower half-life limits of the 2+1 state transitions of 0ν\{beta}\{beta} and 2ν\{beta}\{beta} decay were improved to T(0ν, 0+ \rightarrow 2+) > 2.6\times10^25 yr and T(2ν, 0+ \rightarrow 2+) > 4.6\times10^23 yr (90% C.L.), respectively. We report on the first experimental lower half-life limits for the transitions to the 0+1 state of 136Xe for 0ν\{beta}\{beta} and 2ν\{beta}\{beta} decay. They are T (0ν, 0+ \rightarrow 0+) > 2.4\times10^25 yr and T(2ν, 0+ \rightarrow 0+) > 8.3\times10^23 yr (90% C.L.). The transitions to the 2+2 states are also evaluated for the first time to be T(0ν, 0+ \rightarrow 2+) > 2.6\times10^25 yr and T(2ν, 0+ \rightarrow 2+) > 9.0\times10^23 yr (90% C.L.). These results are compared to recent theoretical predictions.

hep-ex

7Be Solar Neutrino Measurement with KamLAND

We report a measurement of the neutrino-electron elastic scattering rate of 862 keV 7Be solar neutrinos based on a 165.4 kton-day exposure of KamLAND. The observed rate is 582 +/- 90 (kton-day)^-1, which corresponds to a 862 keV 7Be solar neutrino flux of (3.26 +/- 0.50) x 10^9 cm^-2s^-1, assuming a pure electron flavor flux. Comparing this flux with the standard solar model prediction and further assuming three flavor mixing, a nu_e survival probability of 0.66 +/- 0.14 is determined from the KamLAND data. Utilizing a global three flavor oscillation analysis, we obtain a total 7Be solar neutrino flux of (5.82 +/- 0.98) x 10^9 cm^-2s^-1, which is consistent with the standard solar model predictions.

hep-ex

Enhancement of muonium emission rate from silica aerogel with a laser ablated surface

Emission of muonium ($μ^+e^-$) atoms from a laser-processed aerogel surface into vacuum was studied for the first time. Laser ablation was used to create hole-like regions with diameter of about 270$~μ$m in a triangular pattern with hole separation in the range of 300--500$~μ$m. The emission probability for the laser-processed aerogel sample is at least eight times higher than for a uniform one.

physics.ins-det

CeLAND: search for a 4th light neutrino state with a 3 PBq 144Ce-144Pr electron antineutrino generator in KamLAND

The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq (75-100 kCi scale) 144Ce-144Pr antineutrino beta-source deployed at the center or next to a large low-background liquid scintillator detector. The antineutrino generator will be produced by the Russian reprocessing plant PA Mayak as early as 2014, transported to Japan, and deployed in the Kamioka Liquid Scintillator Anti-Neutrino Detector (KamLAND) as early as 2015. KamLAND's 13 m diameter target volume provides a suitable environment to measure the energy and position dependence of the detected neutrino flux. A characteristic oscillation pattern would be visible for a baseline of about 10 m or less, providing a very clean signal of neutrino disappearance into a yet-unknown, sterile neutrino state. This will provide a comprehensive test of the electron dissaperance neutrino anomalies and could lead to the discovery of a 4th neutrino state for Delta_m^2 > 0.1 eV^2 and sin^2(2theta) > 0.05.

physics.ins-det

Calibration of the Super-Kamiokande Detector

Procedures and results on hardware level detector calibration in Super-Kamiokande (SK) are presented in this paper. In particular, we report improvements made in our calibration methods for the experimental phase IV in which new readout electronics have been operating since 2008. The topics are separated into two parts. The first part describes the determination of constants needed to interpret the digitized output of our electronics so that we can obtain physical numbers such as photon counts and their arrival times for each photomultiplier tube (PMT). In this context, we developed an in-situ procedure to determine high-voltage settings for PMTs in large detectors like SK, as well as a new method for measuring PMT quantum efficiency and gain in such a detector. The second part describes the modeling of the detector in our Monte Carlo simulation, including in particular the optical properties of its water target and their variability over time. Detailed studies on the water quality are also presented. As a result of this work, we achieved a precision sufficient for physics analysis over a wide energy range (from a few MeV to above a TeV). For example, the charge determination was understood at the 1% level, and the timing resolution was 2.1 nsec at the one-photoelectron charge level and 0.5 nsec at the 100-photoelectron charge level.

physics.ins-det

White paper: CeLAND - Investigation of the reactor antineutrino anomaly with an intense 144Ce-144Pr antineutrino source in KamLAND

We propose to test for short baseline neutrino oscillations, implied by the recent reevaluation of the reactor antineutrino flux and by anomalous results from the gallium solar neutrino detectors. The test will consist of producing a 75 kCi 144Ce - 144Pr antineutrino source to be deployed in the Kamioka Liquid Scintillator Anti-Neutrino Detector (KamLAND). KamLAND's 13m diameter target volume provides a suitable environment to measure energy and position dependence of the detected neutrino flux. A characteristic oscillation pattern would be visible for a baseline of about 10 m or less, providing a very clean signal of neutrino disappearance into a yet-unknown, "sterile" state. Such a measurement will be free of any reactor-related uncertainties. After 1.5 years of data taking the Reactor Antineutrino Anomaly parameter space will be tested at > 95% C.L.

hep-ex

Dual baseline search for muon antineutrino disappearance at 0.1 eV^2 < Δm^2 < 100 eV^2

The MiniBooNE and SciBooNE collaborations report the results of a joint search for short baseline disappearance of \bar{ν_μ} at Fermilab's Booster Neutrino Beamline. The MiniBooNE Cherenkov detector and the SciBooNE tracking detector observe antineutrinos from the same beam, therefore the combined analysis of their datasets serves to partially constrain some of the flux and cross section uncertainties. Uncertainties in the ν_μ background were constrained by neutrino flux and cross section measurements performed in both detectors. A likelihood ratio method was used to set a 90% confidence level upper limit on \bar{ν_μ} disappearance that dramatically improves upon prior limits in the Δm^2=0.1-100 eV^2 region.

hep-ex

Dual baseline search for muon neutrino disappearance at 0.5 eV^2 < Δm^2 < 40 eV^2

The SciBooNE and MiniBooNE collaborations report the results of a ν_μdisappearance search in the Δm^2 region of 0.5-40 eV^2. The neutrino rate as measured by the SciBooNE tracking detectors is used to constrain the rate at the MiniBooNE Cherenkov detector in the first joint analysis of data from both collaborations. Two separate analyses of the combined data samples set 90% confidence level (CL) limits on ν_μdisappearance in the 0.5-40 eV^2 Δm^2 region, with an improvement over previous experimental constraints between 10 and 30 eV^2.

hep-ex

Measurement of K+ production cross section by 8 GeV protons using high energy neutrino interactions in the SciBooNE detector

The SciBooNE Collaboration reports K+ production cross section and rate measurements using high energy daughter muon neutrino scattering data off the SciBar polystyrene (C8H8) target in the SciBooNE detector. The K+ mesons are produced by 8 GeV protons striking a beryllium target in Fermilab Booster Neutrino Beam line (BNB). Using observed neutrino and antineutrino events in SciBooNE, we measure d2σ/dpdΩ = (5.34 \times 0.76) mb/(GeV/c \times sr) for p + Be -> K+ + X at mean K+ energy of 3.9 GeV and angle (with respect to the proton beam direction) of 3.7 degrees, corresponding to the selected K+ sample. Compared to Monte Carlo predictions using previous higher energy K+ production measurements, this measurement, which uses the NUANCE neutrino interaction generator, is consistent with a normalization factor of 0.85\times0.12. This agreement is evidence that the extrapolation of the higher energy K+ measurements to an 8 GeV beam energy using Feynman scaling is valid. This measurement reduces the error on the K+ production cross section from 40% to 14%.

hep-ex

Measurement of inclusive charged current interactions on carbon in a few-GeV neutrino beam

The SciBooNE Collaboration reports a measurement of inclusive charged current interactions of muon neutrinos on carbon with an average energy of 0.8 GeV using the Fermilab Booster Neutrino Beam. We compare our measurement with two neutrino interaction simulations: NEUT and NUANCE. The charged current interaction rates (product of flux and cross section) are extracted by fitting the muon kinematics, with a precision of 6-15% for the energy dependent and 3% for the energy integrated analyses. We also extract CC inclusive interaction cross sections from the observed rates, with a precision of 10-30% for the energy dependent and 8% for the energy integrated analyses. This is the first measurement of the CC inclusive cross section on carbon around 1 GeV. These results can be used to convert previous SciBooNE cross section ratio measurements to absolute cross section values.

hep-ex

Performance of Multi-Pixel Photon Counters for the T2K near detectors

We have developed a Multi-Pixel Photon Counter (MPPC) for the neutrino detectors of T2K experiment. About 64,000 MPPCs have been produced and tested in about a year. In order to characterize a large number of MPPCs, we have developed a system that simultaneously measures 64 MPPCs with various bias voltage and temperature. The performance of MPPCs are found to satisfy the requirement of T2K experiment. In this paper, we present the performance of 17,686 MPPCs measured at Kyoto University.

physics.ins-det