SearcharxivSearch

arXiv subjects

M. P. Green

Publications and source records attributed to M. P. Green.

At least 19 recordsLinked to original sources

Energy Calibration and Performance of HPGe Detectors in the LEGEND-200 Experiment

This paper describes the energy scale procedures and germanium detectors performance in the LEGEND-200 experiment, a critical component for the first unblinding in the search for neutrinoless double beta decay. We detail the digital signal processing pipeline, the methodologies for peak-shape modeling and energy calibration procedures utilizing weekly $^{228}$Th source calibration runs. The optimized energy reconstruction achieves a combined average resolution of $(2.47 \pm 0.08)$~keV at $Q_{ββ} = 2039$~keV. The weekly variation of calibration peak positions are below 0.05~keV for energies up to 2614.5~keV, showing a high stability of the energy scale over time and across detectors. Furthermore, systematic corrections effectively address residual non-linearities and energy bias in the region of interest.

physics.ins-det

Measurement of coherent elastic neutrino nucleus scattering on germanium by COHERENT

The COHERENT collaboration reports the most precise measurement of the coherent elastic neutrino-nucleus scattering cross section to date. This measurement was performed with COHERENT's germanium detector array, Ge-Mini, at the Spallation Neutron Source at Oak Ridge National Laboratory. A cumulative exposure of $4.68\times10^{22}$ protons on target yielded a total number of observed counts of $124^{+14}_{-12}$ and a flux-averaged cross section of $1.00 \pm 0.10 \mathrm{(statistical)} \pm 0.10 \mathrm{(systematic)}$ relative to the standard-model expectation of $5.9\times10^{-39} \mathrm{cm}^2$. The well-understood energy and timing distributions of the neutrino source allow for independent measurements of muon- and electron-neutrino scattering rates. This information is used to improve constraints on non-standard neutrino interactions mediated by heavy particles.

hep-ex

The COHERENT Experiment: 2026 Update

The COHERENT experiment measures neutrino-induced recoils from coherent elastic neutrino-nucleus scattering (CEvNS) with multiple nuclear targets at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), USA. Several successful CEvNS measurements have been achieved in recent years with tens-of-kg detector masses, with a CsI scintillating crystal, a liquid argon single-phase detector, and high-purity germanium spectrometers. For the next phase, COHERENT aims at high-statistics detection of CEvNS events for precision tests of the standard model of particle physics, and to probe new physics beyond-the-standard model. Percent-level precision can be achieved by lowering thresholds, reducing backgrounds, and by scaling up the detector masses. It goes hand in hand with benchmarking the neutrino flux from the SNS. Further detectors will measure CEvNS in additional nuclei, including lighter target nuclei such as sodium and neon, to continue to test the expected neutron-number-squared dependence of the cross section. COHERENT can furthermore study charged-current and neutral-current inelastic neutrino-nucleus cross sections on various nuclei at neutrino energies below $\sim$50 MeV. Many of these cross sections have never been measured before, but are critical input for the interpretation of core-collapse supernova detection in large-scale neutrino experiments such as DUNE, Super-K, Hyper-K, and HALO.

hep-ex

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT's Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe a on-beam excess of 20.6 +7.1 -6.3 counts with a total exposure of 10.22 GWhkg and we reject the no-CEvNS hypothesis with 3.9 sigma significance. The result agrees with the predicted standard model of particle physics signal rate within 2 sigma.

hep-ex

First Results on the Search for Lepton Number Violating Neutrinoless Double Beta Decay with the LEGEND-200 Experiment

The LEGEND collaboration is searching for neutrinoless double beta ($0νββ$) decay by operating high-purity germanium detectors enriched in $^{76}$Ge in a low-background liquid argon environment. Building on key technological innovations from GERDA and the MAJORANA DEMONSTRATOR, LEGEND-200 has performed a first $0νββ$ decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of $0.5^{+0.3}_{-0.2}$ cts/(keV kg yr) in the $0νββ$ decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of $2.8 \times 10^{26}$ yr on the half-life of $0νββ$ decay, reveals no evidence for a signal and sets a new observed lower limit at $T^{0ν}_{1/2} > 1.9 \times 10^{26}$ yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range $m_{ββ} < 75-200$ meV, depending on the adopted nuclear matrix element.

hep-ex

Rare multi-nucleon decays with the full data sets of the Majorana Demonstrator

The Majorana Demonstrator was an ultra-low-background experiment designed for neutrinoless double-beta decay ($0νββ$) investigation in $^{76}$Ge. Located at the Sanford Underground Research Facility in Lead, South Dakota, the Demonstrator utilized modular high-purity Ge detector arrays within shielded vacuum cryostats, operating deep underground. The arrays, with a capacity of up to 40.4 kg (27.2 kg enriched to $\sim 88\%$ in $^{76}$Ge), have accumulated the full data set, totaling 64.5 kg yr of enriched active exposure and 27.4 kg yr of exposure for natural detectors. Our updated search improves previously explored three-nucleon decay modes in Ge isotopes, setting new partial lifetime limits of $1.83\times10^{26}$ years (90\% confidence level) for $^{76}$Ge($ppp$) $\rightarrow$ $^{73}$Cu e$^+π^+π^+$ and $^{76}$Ge($ppn$) $\rightarrow$ $^{73}$Zn e$^+π^+$. The partial lifetime limit for the fully inclusive tri-proton decay mode of $^{76}$Ge is found to be $2.1\times10^{25}$ yr. Furthermore, we have updated limits for corresponding multi-nucleon decays.

nucl-ex

Final Results of the MAJORANA DEMONSTRATOR's Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se

$^{76}$Ge can $ββ$ decay into three possible excited states of $^{76}$Se, with the emission of two or, if the neutrino is Majorana, zero neutrinos. None of these six transitions have yet been observed. The MAJORANA DEMONSTRATOR was designed to study $ββ$ decay of $^{76}$Ge using a low background array of high purity germanium detectors. With 98.2 kg-y of isotopic exposure, the DEMONSTRATOR sets the strongest half-life limits to date for all six transition modes. For $2νββ$ to the $0^+_1$ state of $^{76}$Se, this search has begun to probe for the first time half-life values predicted using modern many-body nuclear theory techniques, setting a limit of $T_{1/2}>1.5\times10^{24}$ y (90% CL).

nucl-ex

Search for charge nonconservation and Pauli exclusion principle violation with the Majorana Demonstrator

Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detectors of the \MJD\ experiment. Using a 37.5 kg-yr exposure, we report a lower limit on the electron mean lifetime, improving the previous best limit for the $e \rightarrow ν_e \overline{ν_e} ν_e$ decay channel by more than an order of magnitude. We also present searches for two types of violation of the Pauli exclusion principle, setting limits on the probability of an electron to be found in a symmetric quantum state.

nucl-ex

The MAJORANA DEMONSTRATOR experiment's construction, commissioning, and performance

Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to justify building a tonne-scale experiment to search for the neutrinoless double-beta decay ($ββ(0ν)$) of $^{76}\mathrm{Ge}$. Purpose: This paper presents a description of the instrument, its commissioning, and operations. It covers the electroforming, underground infrastructure, enrichment, detector fabrication, low-background and construction techniques, electronics, data acquisition, databases, and data processing of the MAJORANA DEMONSTRATOR. Method: The MAJORANA DEMONSTRATOR operated inside an ultra-low radioactivity passive shield at the 4850-foot~level of the Sanford Underground Research Facility (SURF) from 2015-2021. Results and Conclusions: The MAJORANA DEMONSTRATOR achieved the best energy resolution and second-best background level of any $ββ(0ν)$ search. This enabled it to achieve an ultimate half-life limit on $ββ(0ν)$ in $^{76}\mathrm{Ge}$ of $8.3\times 10^{25}$~yr (90\% C.L.) and perform a rich set of searches for other physics beyond the Standard Model.

physics.ins-det

Interpretable Boosted Decision Tree Analysis for the Majorana Demonstrator

The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logic, allowing us to learn from the machine to feedback to the traditional analysis. In this work, we have presented the first machine learning analysis of the data from the Majorana Demonstrator; this is also the first interpretable machine learning analysis of any germanium detector experiment. Two gradient boosted decision tree models are trained to learn from the data, and a game-theory-based model interpretability study is conducted to understand the origin of the classification power. By learning from data, this analysis recognizes the correlations among reconstruction parameters to further enhance the background rejection performance. By learning from the machine, this analysis reveals the importance of new background categories to reciprocally benefit the standard Majorana analysis. This model is highly compatible with next-generation germanium detector experiments like LEGEND since it can be simultaneously trained on a large number of detectors.

physics.data-an

An assay-based background projection for the MAJORANA DEMONSTRATOR using Monte Carlo Uncertainty Propagation

The background index is an important quantity which is used in projecting and calculating the half-life sensitivity of neutrinoless double-beta decay ($0νββ$) experiments. A novel analysis framework is presented to calculate the background index using the specific activities, masses and simulated efficiencies of an experiment's components as distributions. This Bayesian framework includes a unified approach to combine specific activities from assay. Monte Carlo uncertainty propagation is used to build a background index distribution from the specific activity, mass and efficiency distributions. This analysis method is applied to the MAJORANA DEMONSTRATOR, which deployed arrays of high-purity Ge detectors enriched in $^{76}$Ge to search for $0νββ$. The framework projects a mean background index of $\left[8.95 \pm 0.36\right] \times 10^{-4}$cts/(keV kg yr) from $^{232}$Th and $^{238}$U in the DEMONSTRATOR's components.

nucl-ex

Exotic dark matter search with the Majorana Demonstrator

With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos, $ν_s \rightarrow ν_a$. We report new limits on fermionic dark matter absorption ($χ+ A \rightarrow ν+ A$) and sub-GeV DM-nucleus 3$\rightarrow$2 scattering ($χ+ χ+ A \rightarrow ϕ+ A$), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the (1--100)-keV low energy region of a 37.5-kg y exposure collected by the Demonstrator between May 2016 and November 2019, using a set of $^{76}$Ge-enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation.

hep-ex

Measurement of the Electron-Neutrino Charged-Current Cross Sections on ${}^{127}$I with the COHERENT NaI$ν$E detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy ($\leq$ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of $9.2^{+2.1}_{-1.8} \times 10^{-40}$ cm$^2$. This corresponds to a value that is $\sim$41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on $^{127}$I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be $5.2^{+3.4}_{-3.1} \times 10^{-40}$ and $2.2^{+3.5}_{-2.2} \times 10^{-40}$ cm$^2$, respectively.

nucl-ex

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several beyond-the-standard-model scenarios such as neutrino non-standard interactions and accelerator-produced dark matter. This detector's performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of CsI nuclei and detection of neutrinos from a core-collapse supernova.

hep-ex

Measurement of ${}^{nat}$Pb($ν_e$,X$n$) production with a stopped-pion neutrino source

Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($ν_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector are fit jointly with previously collected COHERENT data on this process. A combined analysis of the two datasets yields a cross section that is $0.29^{+0.17}_{-0.16}$ times that predicted by the MARLEY event generator using experimentally-measured Gamow-Teller strength distributions, consistent with no NIN events at 1.8$σ$. This is the first inelastic neutrino-nucleus process COHERENT has studied, among several planned exploiting the high flux of low-energy neutrinos produced at the SNS.

hep-ex

Majorana Demonstrator Data Release for AI/ML Applications

The enclosed data release consists of a subset of the calibration data from the Majorana Demonstrator experiment. Each Majorana event is accompanied by raw Germanium detector waveforms, pulse shape discrimination cuts, and calibrated final energies, all shared in an HDF5 file format along with relevant metadata. This release is specifically designed to support the training and testing of Artificial Intelligence (AI) and Machine Learning (ML) algorithms upon our data. This document is structured as follows. Section I provides an overview of the dataset's content and format; Section II outlines the location of this dataset and the method for accessing it; Section III presents the NPML Machine Learning Challenge associated with this dataset; Section IV contains a disclaimer from the Majorana collaboration regarding the use of this dataset; Appendix A contains technical details of this data release. Please direct questions about the material provided within this release to liaobo77@ucsd.edu (A. Li).

cs.LG

Energy Calibration of Germanium Detectors for the MAJORANA DEMONSTRATOR

The MAJORANA DEMONSTRATOR was a search for neutrinoless double-beta decay ($0νββ$) in the $^{76}$Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a $^{228}$Th line source for 1 to 2 hours. The energy scale calibration determination for the detector array was automated using custom analysis tools. We describe the offline procedure for calibration of the Demonstrator germanium detectors, including the simultaneous fitting of multiple spectral peaks, estimation of energy scale uncertainties, and the automation of the calibration procedure.

physics.ins-det

COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils

Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the transparency and reproducibility of our results. This document describes the contents of the data release as well as guidance on the use of the data.

physics.ins-det