SearcharxivSearch

arXiv subjects

M. P. Ross

Publications and source records attributed to M. P. Ross.

12 recordsLinked to original sources

An Improved Torsion Balance Test of the Equivalence Principle Towards the Sun

We search for violations of the Equivalence Principle towards the Sun using a rotating torsion balance apparatus. We set 95\%-confidence limits on violations with beryllium and aluminum test bodies of $\eta_{\odot, Be-Al} \leq 2.1 \times 10^{-13}$. These results are a factor of four improvement of previously reported results towards the Sun and a $\sim20\%$ improvement on previous torsion balance tests regardless of source.

gr-qc

A Search for Ultra-Light Vector Dark Matter with a Rotating Torsion Balance

We search for ultra-light vector dark matter interacting with a rotating torsion balance with a baryon minus lepton number composition dipole. Our search spans candidate masses in the ultra-low mass range from 1.3~$\times10^{-22}$ to 1.9~$\times10^{-18}$ eV. We set limits on the coupling strength to baryon minus lepton number for each dark matter candidate reaching a peak sensitivity of $g_{B-L} \leq 9 \times 10^{-26}$.

hep-ex

Probing For Non-Gravitational Long-Range Dark Matter Interactions

Dark matter remains a mystery in fundamental physics. The only evidence for dark matter's existence is from gravitational interactions. We constructed a precision torsion balance experiment to search for non-gravitational, long-range interactions between ordinary matter in our lab and the Milky Way's dark matter. We find no evidence of such interaction and set strict upper bounds on its strength. These results suggest that dark matter only interacts gravitationally over long distances and constrains a variety of dark matter theories.

gr-qc

Test of the Equivalence Principle for Superconductors

We searched for violations of the weak equivalence principle using a cryogenic torsion balance with a pendulum comprised of superconducting niobium and copper. We constrain the Eötvös parameter with 95%-confidence to $η_{\text{Nb*-Cu}}~\leq~2.0\times10^{-9}$ and $η_{\text{CP-ee}}\leq9.2\times10^{-4}$ for superconducting niobium and Cooper pairs, respectively.

gr-qc

A Vacuum-Compatible Cylindrical Inertial Rotation Sensor with Picoradian Sensitivity

We describe an inertial rotation sensor with a 30-cm cylindrical proof-mass suspended from a pair of 14-$μ$m thick BeCu flexures. The angle between the proof-mass and support structure is measured with a pair of homodyne interferometers which achieve a noise level of $\sim 5\ \text{prad}/\sqrt{\text{Hz}}$. The sensor is entirely made of vacuum compatible materials and the center of mass can be adjusted remotely.

physics.ins-det

A Pseudo Plane-wave Gravitational Calibrator for Gravitational Wave Observatories

The precisions of existing gravitational calibrators for gravitational wave observatories are limited by their dependence on the relative position between the calibrators and the observatory's test masses. Here we present a novel geometry consisting of four quadrupole rotors placed at the vertices of a rectangle centered on the test mass. The phases and rotation directions are selected to produce a pseudo plane-wave sinusoidal gravitational acceleration with amplitude of ~ 100 fm/s^2. We show that this acceleration only has minimal dependence on the test mass position relative to the rotor array and can yield 0.15% acceleration amplitude uncertainty while tolerating a 1-cm test mass position uncertainty. The acceleration can be directed precisely along the optical axis of the interferometer arm and applies no torque on the test mass. In addition, the small size of the rotors has significant engineering and safety benefits.

gr-qc

A Cryogenic Torsion Balance Using a Liquid-Cryogen Free, Ultra-Low Vibration Cryostat

We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency range of 3-10mHz, limited by residual seismic motion and by radiative heating of the pendulum body. In addition to lowering thermal noise below room-temperature limits, the low-temperature environment enables novel torsion balance experiments. Currently, the maximum duration of a continuous measurement run is limited by accumulation of cryogenic surface contamination on the optical elements inside the cryostat.

physics.ins-det

A torsion-balance search for ultra low-mass bosonic dark matter

We used a stationary torsion balance with a beryllium-aluminum composition dipole to search for ultra low-mass bosonic dark matter coupled to baryon minus lepton number. We set 95% confidence limits on the coupling constant $g_{\rm B-L}$ for bosons with masses between $10^{-18}$ and $10^{-16}$ eV/$c^2$ with the best performance at $m_{\rm DM} = 8\times 10^{-18}$ eV/$c^2$ constraining $g_{B-L}(\hbar c)^{-1/2} < 1 \times 10^{-25}$. This provides a complimentary limit to equivalence-principle experiments that search for ultra low-mass bosons as force-mediating particles.

astro-ph.CO

A Low-Frequency Torsion Pendulum with Interferometric Readout

We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a modified Michelson interferometer. The system achieved noise levels of $\sim200\ \text{prad}/\sqrt{\text{Hz}}$ between 0.2-30 Hz and $\sim10\ \text{prad}/\sqrt{\text{Hz}}$ above 100 Hz. Such a system can be applied to a broad range of fields from the study of rotational seismic motion and elastogravity signals to gravitational wave observation and tests of gravity.

physics.ins-det

Limits on the Stochastic Gravitational Wave Background and Prospects for Single Source Detection with GRACE Follow-On

With a reinterpretation of recent results, the GRACE Follow-On mission can be applied to gravitational wave astronomy. Existing GRACE Follow-On data constrain the stochastic gravitational wave background to $Ω_{GW}<3.3\times10^{7}$ at 100 mHz. With a dedicated analysis, GRACE Follow-On may be able to detect the inspiral of local neutron star binaries, inspiral of subgalactic stellar-mass black hole binaries, or mergers of intermediate-mass black hole binaries within the Milky Way.

gr-qc

Implications of dedicated seismometer measurements on Newtonian-noise cancellation for Advanced LIGO

Newtonian gravitational noise from seismic fields will become a limiting noise source at low frequency for second-generation, gravitational-wave detectors. It is planned to use seismic sensors surrounding the detectors' test masses to coherently subtract Newtonian noise using Wiener filters derived from the correlations between the sensors and detector data. In this work, we use data from a seismometer array deployed at the corner station of the LIGO Hanford detector combined with a tiltmeter for a detailed characterization of the seismic field and to predict achievable Newtonian-noise subtraction levels. As was shown previously, cancellation of the tiltmeter signal using seismometer data serves as the best available proxy of Newtonian-noise cancellation. According to our results, a relatively small number of seismometers is likely sufficient to perform the noise cancellation due to an almost ideal two-point spatial correlation of seismic surface displacement at the corner station, or alternatively, a tiltmeter deployed under each of the two test masses of the corner station at Hanford will be able to efficiently cancel Newtonian noise. Furthermore, we show that the ground tilt to differential arm-length coupling observed during LIGO's second science run is consistent with gravitational coupling.

astro-ph.IM

Low Frequency Tilt Seismology with a Precision Ground Rotation Sensor

We describe measurements of the rotational component of teleseismic surface waves using an inertial high-precision ground-rotation-sensor installed at the LIGO Hanford Observatory (LHO). The sensor has a noise floor of 0.4 nrad$/ \sqrt{\rm Hz}$ at 50 mHz and a translational coupling of less than 1 $μ$rad/m enabling translation-free measurement of small rotations. We present observations of the rotational motion from Rayleigh waves of six teleseismic events from varied locations and with magnitudes ranging from M6.7 to M7.9. These events were used to estimate phase dispersion curves which shows agreement with a similar analysis done with an array of three STS-2 seismometers also located at LHO.

physics.geo-ph