SearcharxivSearch

arXiv subjects

M. Paganoni

Publications and source records attributed to M. Paganoni.

6 recordsLinked to original sources

The CMS Barrel Timing Layer: test beam confirmation of module timing performance

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30-60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 $\rm \mu m$ cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.

physics.ins-det

Exploring Scintillators and Cherenkov Radiators for MIP Timing Detectors

This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section 2 x 2 mm2 or 3 x 3 mm2 and length of 3 or 10 mm were coupled to Hamamatsu SiPM and read out by fast high-frequency electronics. Materials whose timing performance relies on Cherenkov emission, namely BGSO, PWO, and PbF2, achieved time resolutions in the range 24-36ps. Scintillators as L(Y)SO:Ce, GAGG, and BaF2 reached below 15 ps, the best topping at 12.1 +/- 0.4 ps. These fast materials are compared to LYSO and their additional benefit is discussed. Given the promising results of BaF2, the study is completed with measurements of the scintillation properties of a set doped with yttrium to quench the slow light emission.

physics.ins-det

Optimization of LYSO crystals and SiPM parameters for the CMS MIP timing detector

For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, the barrel timing layer (BTL), is designed to provide a measurement of the time of arrival of charged particles with a precision of 30 ps at the beginning of HL-LHC, progressively degrading to 60 ps while operating in an extremely harsh radiation environment for over a decade. In this paper we present a comparative analysis of the time resolution of BTL module prototypes made of LYSO:Ce crystal bars read out by silicon photo-multipliers (SiPMs). The timing performance measured in beam test campaigns is presented for prototypes with different construction and operation parameters, such as different SiPM cell sizes (15, 20, 25 and 30 $\rm \mu m$), SiPM manufacturers and crystal bar thicknesses. The evolution of time resolution as a function of the irradiation level has been studied using non-irradiated SiPMs as well as SiPMs exposed up to $2\times 10^{14}~n_{eq}/cm^2$ fluence. The key parameters defining the module time resolution such as SiPM characteristics (gain, photon detection efficiency, radiation induced dark count rate) and crystal properties (light output and dimensions) are discussed. These results have informed the final choice of the MTD barrel sensor configuration and offer a unique starting point for the design of future large-area scintillator-based timing detectors in either low or high radiation environments.

physics.ins-det

The running of the electromagnetic coupling alpha in small-angle Bhabha scattering

A method to determine the running of alpha from a measurement of small-angle Bhabha scattering is proposed and worked out. The method is suited to high statistics experiments at e+e- colliders, which are equipped with luminometers in the appropriate angular region. A new simulation code predicting small-angle Bhabha scattering is also presented

hep-ph

Measurement of neutrino oscillations by means of a high density detector on the atmospheric neutrino beam

A high-density calorimeter, consisting of magnetized iron planes interleaved by RPCs, as tracking and timing devices, is a good candidate for a next generation experiment on atmospheric neutrinos. With 34 kt of mass and in four years of data taking, this experiment will be sensitive to $ν_μ\to ν_x$ oscillation with $Δm^2 > 6 \times 10^{-5}$ and mixing near to maximal and fully cover the region of oscillation parameters suggested by Super-Kamiokande results. Moreover, the experimental method will enable to measure the oscillation parameters from the modulation of the L/E spectrum ($ν_μ$ disappearance). For $Δm^2 > 3 \times 10^{-3}$ eV$^2$, this experiment can also establish whether the oscillation occurs into a tau or a sterile neutrino, by looking for an excess of muon-less events at high energies produced by upward-going tau neutrinos ($ν_τ$ appearance).

hep-ex

An electromagnetic shashlik calorimeter with longitudinal segmentation

A novel technique for longitudinal segmentation of shashlik calorimeters has been tested in the CERN West Area beam facility. A 25 tower very fine samplings e.m. calorimeter has been built with vacuum photodiodes inserted in the first 8 radiation lengths to sample the initial development of the shower. Results concerning energy resolution, impact point reconstruction and electron/pion separation are reported.

hep-ex