SearcharxivSearch

arXiv subjects

M. Platt

Publications and source records attributed to M. Platt.

At least 19 recordsLinked to original sources

Exploring Low Energy Excess in MINER with sapphire detectors using Convolutional Variational Autoencoder (CVAE)

As cryogenic detectors push toward ever-lower energy thresholds, their sensitivity is increasingly constrained by a persistent low-energy background known as the low-energy excess (LEE). We report observation of LEE in the MINER experiment using a sapphire ($\mathrm{Al_2O_3}$) detector at energies around 200 eV, with the excess reproducibly reappearing after each non-operational warm-up period. To address this limiting background, we implement an unsupervised convolutional variational autoencoder (CVAE) framework that identifies anomalous events through a reconstruction-based anomaly score. For the first time in a pulse-shape driven analysis, we uncover a significant deviation in the rise-time of LEE events relative to Monte Carlo simulated ideal signals. Using this feature, we develop a discrimination pipeline based on rise-time selection. This method achieves up to 53\% rejection of LEE events, corresponding to an expected sensitivity improvement of nearly 10\% for MINER at HFIR. These findings are consistent with a scenario in which a substantial fraction of the LEE originates from bulk-related defects or microfractures within the detector crystal, while leaving room for additional detector-related contributions. Our result provides a powerful, data-driven pathway for mitigating LEE and enhancing the discovery potential of next-generation cryogenic experiments.

physics.ins-det

Low Energy Phonon Bursts Created By Fast Neutron Damage

Solid state athermal phonon calorimeters used in the search for low mass dark matter or coherent neutrino-nucleus interactions have long observed a large excess of events below several hundred eV. The relaxation of damage created by the interaction of fast cosmic ray neutrons with the detector has been proposed as a source of these excess events. By comparing neutron exposed detectors to control detectors, we report the first measurement of phonon bursts caused by damage created by fast neutrons. Differences in the spectral shape, the rate dependence on thermal history, and the observed spectral rate scaled to the neutron exposure between irradiated and control detectors suggest that our observed LEE backgrounds are not dominated by neutron damage-induced phonon bursts.

physics.ins-det

Characterization of a CsI(Tl) Scintillator Coupled to a SiPM at Cryogenic Temperatures

We report on the scintillation characterization of a 1 cm^3 CsI(Tl) crystal coupled to a 6 x 6 mm^2 SiPM read out with a custom transimpedance amplifier at cryogenic temperatures. The crystal was prepared with optical-grade surfaces and enclosed in a multi layer shielding system to suppress ambient light and background radiation. The detector response was studied at temperatures ranging from 100 K to room temperature. A figure of merit, defined as the ratio of the 59.5 keV peak position to the baseline resolution, showed a maximum at 175 K, indicating optimal photon detection efficiency. Pulse shape analysis demonstrated temperature-dependent variations in scintillation decay. At 175 K, the baseline resolution was sigma ~ 1 keV, corresponding to an effective threshold of ~ 3 keV. These results confirm the capability of the CsI(Tl) SiPM system to operate at low thresholds for rare-event searches and low-energy particle detection.

physics.ins-det

CE$\nu$NS Search with Cryogenic Sapphire Detectors at MINER: Results from the TRIGA reactor data and Future Sensitivity at HFIR

We report on a search for coherent elastic neutrino--nucleus scattering (CE$\nu$NS) using cryogenic sapphire (Al$_2$O$_3$) detectors deployed at the Mitchell Institute Neutrino Experiment at Reactor (MINER), located near the 1~MW$_\text{th}$ TRIGA research reactor at Texas A\&M University. The experiment operated with a primary detector mass of 72~g and achieved a baseline energy resolution of $\sim 40$~eV. Using exposures of 158~g-days (reactor-on) and 381~g-days (reactor-off), we performed a statistical background subtraction in the energy region of 0.25--3~keV. A GEANT4 simulation has been performed to understand the reactor-correlated background present in the data and it agrees with our observations. The resulting best-fit ratio of the observed CE$\nu$NS rate to the Standard Model prediction after rejecting the reactor induced background from the data with the help of simulation, is $\rho = 0.26\pm 1534.74~\mathrm{(stat)} \pm 0.05~\mathrm{(sys)}$ with a significance of $0.007 \pm 0.022~\mathrm{(stat)} \pm 0.001~\mathrm{(sys)}$. This low significance indicates a high background rate at low energies. To have enhanced sensitivity, the MINER collaboration plans to relocate the experiment to the 85~MW$_\text{th}$ High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). With improved shielding, increased detector mass, and higher antineutrino flux, the upgraded setup is projected to achieve a 3$\sigma$ CE$\nu$NS detection within 30~kg$\cdot$days of exposure.

nucl-ex

Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events and quasiparticle poisoning in superconducting sensors

Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE$\nu$NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from sub-threshold bursts. In this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm$^2$ silicon detectors that differ only in the thickness of their substrate (1 mm vs. 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for sub-threshold noise events is $0.68 \pm 0.38$ meV. In our final dataset, we report a world-leading energy resolution of 258.5$\pm$0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.

physics.ins-det

MINER Reactor Based Search for Axion-Like Particles Using Sapphire (Al2O3) Detectors

The absence of definitive results for WIMP dark matter has sparked growing interest in alternative dark matter candidates, such as axions and Axion-Like Particles (ALPs), which also provide insight into the strong CP problem. The Mitchell Institute Neutrino Experiment at Reactor (MINER), conducted at the Nuclear Science Center of Texas A&M University, investigated ALPs near a 1 MW TRIGA nuclear reactor core, positioned approximately 4 meters away. This experiment employed cryogenic sapphire detectors with a low detection threshold (approximately 100 eV), equipped with a Transition Edge Sensor capable of detecting athermal phonons. Due to the low-background environment, we were able to exclude ALPs with axion-photon coupling and axion-electron coupling as small as \(g_{a\gamma\gamma} = 10^{-5}\) and \(g_{aee} = 10^{-7}\), respectively. Energy depositions below 3 keV were not considered and remain blinded for our Coherent Elastic Neutrino Nucleus Scattering (CEvNS) analysis. This is the first result demonstrating the MINER experiment's potential to probe low-mass ALPs, enabled by its low-threshold detector and proximity to a reactor.

hep-ex

First Limits on Light Dark Matter Interactions in a Low Threshold Two Channel Athermal Phonon Detector from the TESSERACT Collaboration

We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g $\times$ 12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 MeV/$c^2$, with the lowest unexplored cross section of 4 $\times 10^{-32}$ cm$^2$ at 87 MeV/$c^2$. We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low-energy backgrounds that are coupled to individual sensors.

hep-ex

Design Studies Of A Pulsed Quasimonoenergetic 2-keV Neutron Source For Calibration Of Low Threshold Dark Matter Detectors

We describe design studies for a pulsed quasi-monoenergetic 2-keV neutron source for calibration of sub-keV nuclear recoils. Such a calibration is required for detectors sensitive to sub-GeV dark matter and also the coherent elastic scattering of reactor neutrinos. In our design, neutrons from a commercial deuterium-tritium generator are moderated to the keV scale and then filtered to the monoenergetic spectrum using a feature in the neutron cross section of scandium. In this approach, unmoderated high-energy neutrons form a challenging background, along with gammas from neutron capture in the moderator materials. We describe the optimization of the moderator+filter and shielding geometry, and find a geometry that in simulation achieves both the target neutron flux at 2 keV and subdominant rates of background interactions. Lastly, we describe a future path to lower-energy (few eV scale) calibrations using time-of-flight and sub-keV neutrons.

physics.ins-det

Reactor-based Search for Axion-Like Particles using CsI(Tl) Detector

The absence of conclusive signals in weakly interacting massive particle (WIMP) searches has motivated increased interest in alternative dark matter candidates such as axions and axion-like particles (ALPs), which also provide a solution to the strong CP problem. In this work, we employ a $\sim100~\mathrm{kg}$ scale CsI(Tl)-based detector operated in proximity to a nuclear reactor to achieve a sub-100 DRU (differential rate unit, expressed in counts/keV/kg/day) background level in the MeV energy range through a combination of active veto and passive shielding techniques. Such a low-background environment enables sensitivity to ALPs with axion--photon coupling $g_{a\gamma\gamma} \gtrsim 10^{-6}$ and axion--electron coupling in the range $10^{-8} < g_{aee} < 10^{-4}$ for ALP masses between 1~keV and 10~MeV. These results demonstrate that the experiment has the potential to probe previously unexplored regions of parameter space, including the so-called cosmological triangle in the ALP--photon coupling for MeV-scale ALPs.

hep-ex

Improved Modelling of Detector Response Effects in Phonon-based Crystal Detectors used for Dark Matter Searches

Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing non-quantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. We use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modelling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.

physics.ins-det

Exploring Charge Transport Dynamics in a Cryogenic P-Type Germanium Detector

This study explores the dynamics of charge transport within a cryogenic P-type Ge particle detector, fabricated from a crystal cultivated at the University of South Dakota (USD). By subjecting the detector to cryogenic temperatures and an Am-241 source, we observe evolving charge dynamics and the emergence of cluster dipole states, leading to the impact ionization process at 40 mK. Our analysis focuses on crucial parameters: the zero-field cross-section of cluster dipole states and the binding energy of these states. For the Ge detector in our investigation, the zero-field cross-section of cluster dipole states is determined to be $8.45 \times 10^{-11}\pm 4.22\times 10^{-12}~cm^2$. Examination of the binding energy associated with cluster dipole states, formed by charge trapping onto dipole states during the freeze-out process, reveals a value of $0.034 \pm 0.0017$ meV. These findings shed light on the intricate charge states influenced by the interplay of temperature and electric field, with potential implications for the sensitivity in detecting low-mass dark matter.

physics.ins-det

First Demonstration of the HeRALD Superfluid Helium Detector Concept

The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical "quantum evaporation" signal from $^4$He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype "HeRALD v0.1" detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. A key result of this work is the measurement of the quantum evaporation channel's gain of 0.15 $\pm$ 0.01, which will enable $^4$He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5 sigma, which would be sensitive to dark matter masses down to 220 MeV/c$^2$.

physics.ins-det

Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light

We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.

physics.ins-det

Observation of Time-Dependent Internal Charge Amplification in a Planar Germanium Detector at Cryogenic Temperature

For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 minutes after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keV $\gamma$ rays from a $^{241}$Am source is amplified for a short period of time and then decreases back to the baseline. The amplification of charge energy depends strongly on the applied positive bias voltage with drifting holes across the detector. No such phenomenon is visible with drifting electrons across the detector. We find that the observed charge amplification is dictated by the impact ionization of charged states, which has a strong correlation with impurity level and applied electric field. We analyze the dominant physics mechanisms that are responsible for the creation and the impact ionization of charged states. Our analysis suggests that the appropriate level of impurity in a Ge detector can enhance charge yield through the impact ionization of charged states to achieve extremely low-energy detection threshold ($<$ 10 meV) for MeV-scale dark matter searches if the charge amplification can be stabilized.

physics.ins-det

A backing detector for order-keV neutrons

We have designed and tested a large-area (0.15~m$^2$) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy ($<$100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scattering (CE$\nu$NS). We describe the design, construction, and characterization of a prototype. The prototype is designed to have a tagging efficiency of $\sim$25\% at the relevant $\mathcal{O}$(keV) neutron energies, and with a mean capture time of $\sim$17$~\mu$s. The prototype was characterized using a \ce{^{252}Cf} neutron source and agreement with the simulation was observed within a few percent level.

physics.ins-det

A novel active veto prototype detector with an inner target for improved rare event searches

We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass $\sim$500 g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced. A 25 mm diameter germanium inner target detector of mass $\sim$10 g was mounted inside the veto detector. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominantly gamma interactions) could be reduced by $>$ 90$\%$, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. During testing at the experimental site the veto detector prototype achieved a baseline resolution of 1.24 $\pm$ 0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147 $\pm$ 2 eV. The detectors were operated at mK temperatures. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.

physics.ins-det

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive 1-gram Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2)~eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100~V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2~eV threshold with a trigger rate of the order of 20~Hz. The detector's energy scale is calibrated up to 120~keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

physics.ins-det

Large-mass single-electron-resolution detector for dark matter and neutrino elastic interaction searches

Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$\nu$NS). Here, we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of $\sim 1 e^{-}/h^{+}$ pair and a leakage current on the order of $10^{-16}$ A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CE$\nu$NS like searches.

physics.ins-det