Searcharxiv⌕ Search

arXiv subjects

M. Poli Lener

Publications and source records attributed to M. Poli Lener.

15 recordsLinked to original sources

MPGDs for tracking and Muon detection at future high energy physics colliders

In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the envisaged construction of new machines at energy scales up to hundreds TeV or with unprecedented intensity (FCC-hh, FCC-ee, ILC, Muon Collider). Large size, cost-effective, high-efficiency detection systems in high background environments are required in order to accomplish the physics program. MPGDs offer a diversity of technologies that allow them to meet the required performance challenges at future facilities thanks to the specific advantages that each technology provides. MPGDs allow stable operation, with environmentally friendly gas mixtures, at very high background particle flux with high detection efficiency and excellent spatial resolution. These features make MPGD one of the primary choices as precise muon tracking and trigger system in general-purpose detectors at future HEP colliders. In addition, the low material budget and the flexibility of the base material make MPGDs suitable for the development of very light, full cylindrical fine tracking inner trackers at lepton colliders. On-going R&Ds aim at pushing the detector performance at the limits of each technology. We are working in continuing to consolidate the construction and stable operation of large-size detectors, able to cope with large particle fluxes. In this white paper, we describe some of the most prominent MPGD technologies, their performance measurements, the challenges faced in the most recent applications, and the areas of improvement towards efficient tracking and Muon detection at future high energy physics colliders.

physics.ins-det↗

uRANIA-V: an innovative solution for neutron detection in homeland security

Detection of neutrons is becoming of the utmost importance, especially in the studies of radioactive waste and in homeland security applications. The crisis of 3He availability has required the development of innovative techniques. One solution is to develop light gas detectors for neutron counting to be used as portals for ports and airports. The neutron is converted on the Boron-coated cathode, releasing a charged particle, whose passage can be identified by the gas detector. While several technologies have been deployed in the past, the project μRANIA-V ( μRwell Advanced Neutron Identification Apparatus) aims to detect thermal neutrons by means of the μRwell technology, an innovative gas detector. The goal is to produce tiles to operate as portals in homeland security or for radioactive waste management. The technological transfer towards the industry has started, thus the production can be cost-effective also owing to a construction process relatively easier compared to similar apparatus. By reading directly the signals from the amplification stage, the neutrons can be counted with simplified electronics further reducing the total cost. In this paper, the project will be described, with details on the μRwell technology and on the neutron counting, on the test beam performed, and on the future plans.

physics.ins-det↗

u-RANIA: a neutron detector based on μ-RWELL technology

In the framework of the ATTRACT-uRANIA project, funded by the European Community, we are developing an innovative neutron imaging detector based on micro-Resistive WELL ($μ$ -RWELL) technology. The $μ$ -RWELL, based on the resistive detector concept, ensuring an efficient spark quenching mechanism, is a highly reliable device. It is composed by two main elements: a readout-PCB and a cathode. The amplification stage for this device is embedded in the readout board through a resistive layer realized by means of an industrial process with DLC (Diamond-Like Carbon). A thin layer of B$_4$C on the copper surface of the cathode allows the thermal neutrons detection through the release of $^7$Li and $α$ particles in the active volume. This technology has been developed to be an efficient and convenient alternative to the $^3$He shortage. The goal of the project is to prove the feasibility of such a novel neutron detector by developing and testing small planar prototypes with readout boards suitably segmented with strip or pad read out, equipped with existing electronics or readout in current mode. Preliminary results from the test with different prototypes, showing a good agreement with the simulation, will be presented together with construction details of the prototypes and the future steps of the project.

physics.ins-det↗

On the space resolution of the $μ$-RWELL

In MPGD detectors evaluation of the space resolution with the charge centroid (CC) method provides large uncertainty when the impinging particle is not perpendicular to the readout plane. An improvement of the position reconstruction, and thus of the space resolution, is represented by the $μ$TPC algorithm. In this work we report the application of this algorithm to the $μ$-Resistive WELL detector. Moreover a combination of the CC method with the $μ$TPC algorithm is proposed, showing an almost uniform resolution over a wide angular range.

physics.ins-det↗

Triple GEM performance in magnetic field

Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is capable to guarantee a spatial resolution better than 150μmin magnetic field up to a 1 T.

physics.ins-det↗

The micro-RWELL layouts for high particle rate

The $μ$-RWELL is a single-amplification stage resistive Micro-Pattern Gaseous Detector (MPGD). The detector amplification element is realized with a single copper-clad polyimide foil micro-patterned with a blind hole (well) matrix and embedded in the readout PCB through a thin Diamond-Like-Carbon (DLC) sputtered resistive film. The introduction of the resistive layer, suppressing the transition from streamer to spark, allows to achieve large gains ($\geq$10$^4$) with a single amplification stage, while partially reducing the capability to stand high particle fluxes. The simplest resistive layout, designed for low-rate applications, is based on a single-resistive layer with edge grounding. At high particle fluxes this layout suffers of a non-uniform response. In order to get rid of such a limitation different current evacuation geometries have been designed. In this work we report the study of the performance of several high rate resistive layouts tested at the CERN H8-SpS and PSI $π$M1 beam test facilities. These layouts fulfill the requirements for the detectors at the HL-LHC and for the experiments at the next generation colliders FCC-ee/hh and CepC.

physics.ins-det↗

High-resolution tracking in a GEM-Emulsion detector

SHiP (Search for Hidden Particles) is a beam dump experiment proposed at the CERN SPS aiming at the observation of long lived particles very weakly coupled with ordinary matter mostly produced in the decay of charmed hadrons. The beam dump facility of SHiP is also a copious factory of neutrinos of all three kinds and therefore a dedicated neutrino detector is foreseen in the SHiP apparatus. The neutrino detector exploits the Emulsion Cloud Chamber technique with a modular structure, alternating walls of target units and planes of electronic detectors providing the time stamp to the event. GEM detectors are one of the possible choices for this task. This paper reports the results of the first exposure to a muon beam at CERN of a new hybrid chamber, obtained by coupling a GEM chamber and an emulsion detector. Thanks to the micrometric accuracy of the emulsion detector, the position resolution of the GEM chamber as a function of the particle inclination was evaluated in two configurations, with and without the magnetic field

physics.ins-det↗

Unprecedented studies of the low-energy negatively charged kaons interactions in nuclear matter by AMADEUS

The AMADEUS experiment aims to provide unique quality data of $K^-$ hadronic interactions in light nuclear targets, in order to solve fundamental open questions in the non-perturbative strangeness QCD sector, like the controversial nature of the $Λ(1405)$ state, the yield of hyperon formation below threshold, the yield and shape of multi-nucleon $K^-$ absorption, processes which are intimately connected to the possible existence of exotic antikaon multi-nucleon clusters. AMADEUS takes advantage of the DA$Φ$NE collider, which provides a unique source of monochromatic low-momentum kaons and exploits the KLOE detector as an active target, in order to obtain excellent acceptance and resolution data for $K^-$ nuclear capture on H, ${}^4$He, ${}^{9}$Be and ${}^{12}$C, both at-rest and in-flight. During the second half of 2012 a successful data taking was performed with a dedicated pure carbon target implemented in the central region of KLOE, providing a high statistic sample of pure at-rest $K^-$ nuclear interactions. For the future dedicated setups involving cryogenic gaseous targets are under preparation.

nucl-ex↗

Measurement of the strong interaction induced shift and width of the 1s state of kaonic deuterium at J-PARC

The antikaon-nucleon interaction close to threshold provides crucial information on the interplay between spontaneous and explicit chiral symmetry breaking in low-energy QCD. In this context the importance of kaonic deuterium X-ray spectroscopy has been well recognized, but no experimental results have yet been obtained due to the difficulty of the measurement. We propose to measure the shift and width of the kaonic deuterium 1s state with an accuracy of 60 eV and 140 eV respectively at J-PARC. These results together with the kaonic hydrogen data (KpX at KEK, DEAR and SIDDHARTA at DAFNE) will then permit the determination of values of both the isospin I=0 and I=1 antikaon-nucleon scattering lengths and will provide the most stringent constraints on the antikaon-nucleon interaction, promising a breakthrough. Refined Monte Carlo studies were performed, including the investigation of background suppression factors for the described setup. These studies have demonstrated the feasibility of determining the shift and width of the kaonic deuterium atom 1s state with the desired accuracy of 60 eV and 140 eV.

nucl-ex↗

The Resistive-WELL detector: a compact spark-protected single amplification-stage MPGD

In this work we present a novel idea for a compact spark-protected single amplification stage Micro-Pattern Gas Detector (MPGD). The detector amplification stage, realized with a structure very similar to a GEM foil, is embedded through a resistive layer in the readout board. A cathode electrode, defining the gas conversion/drift gap, completes the detector mechanics. The new structure, that we call Resistive-WELL (R-WELL), has some characteristics in common with previous MPGDs, such as C.A.T. and WELL, developed more than ten years ago. The prototype object of the present study has been realized in the 2009 by TE-MPE-EM Workshop at CERN. The new architecture is a very compact MPGD, robust against discharges and exhibiting a large gain ($\sim$6$\times$10$^3$), simple to construct and easy for engineering and then suitable for large area tracking devices as well as huge calorimetric apparata.

physics.ins-det↗

Characterization of a scintillating fibers read by MPPC detectors trigger prototype for the AMADEUS experiment

Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field, make them ideal readout detectors for scintillating fibers as trigger detectors in particle and nuclear physics experiments like AMADEUS, where such detectors are planned to be used to trigger on charged kaon pairs. In order to investigate the detection efficiency of such a system, a prototype setup consisting of 32, 1 mm diameter scintillating fibers, arranged in two double layers of 16 fibers each, and read out by 64 MPPCs with an ad-hoc built readout electronics, was tested at the piM-1 line of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection efficiency and the trigger capability were measured on a beam containing protons, electrons, muons and pions with a momentum of 440 MeV/c. The measured average efficiency for protons for a double layer of scintillating fibers (96.9 +/-1.2%) represents a guarantee of the good performance of this system as a trigger for the AMADEUS experiment.

physics.ins-det↗

A GEM-based Time Projection Chamber for the AMADEUS experiment

In this paper we present the R&D activity on a new GEM-based TPC prototype for AMADEUS, a new experimental proposal at the DAΦNE Φ-factory at the Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. Such innovative detector will equip the inner part of the experiment in order to perfom a better reconstruction of the primary vertex and the secondary particles tracking. A 10x10 cm2 prototype with a drift gap up to 15 cm was realized and succesfully tested at the π M1 beam facility of the Paul Scherrer Institut (PSI) with low momentum hadrons. The measurements of the detector efficiency and spatial resolution have been performed. The results as a function of the gas gain, drift field, front-end electronic threshold and particle momentum are reported and discussed.

physics.ins-det↗

Kaon-nuclei interaction studies at low energies (the AMADEUS project)

The AMADEUS experiment aims to perform dedicated precision studies in the sector of low-energy kaon-nuclei interaction at the DAΦNE collider at LNF-INFN. In particular the experiment plans to perform measurements of the debated deeply bound kaonic nuclear states (by stopping kaons in cryogenic gaseous targets 3He and 4He) to explore the nature of the Λ(1405) in nuclear environment and to measure the cross section of K- on light nuclei, for K- momentum lower than 100 MeV/c. The AMADEUS dedicated setup will be installed in the central region of the KLOE detector.

nucl-ex↗

Performances of a GEM-based Time Projection Chamber prototype for the AMADEUS experiment

A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle experiments greatly exceed the abilities of traditional TPC read out by multi-wire proportional chamber (MWPC). Gas Electron Multiplier (GEM) detector has great potential to improve TPC performances when used as amplification device. In this paper we present the R&D activity on a new GEM-based TPC detector built as a prototype for the inner part for AMADEUS, a new experimental proposal at the DAFNE collider at Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. In order to evaluate the GEM-TPC performances, a 10x10 cm2 prototype with a drift gap up to 15 cm has been realized. The detector was tested at the pM1 beam facility of the Paul Scherrer Institut (PSI) with low momentum pions and protons, without magnetic field. Drift properties of argonisobutane gas mixtures are measured and compared withMagboltz prediction. Detection efficiency and spatial resolution as a function of a large number of parameters, such as the gas gain, the drift field, the front-end electronic threshold and particle momentum, are illustrated and discussed. Particle identification capability and the measurement of the energy resolution in isobutane-based gas mixture are also reported.

physics.ins-det↗

Kaonic 3He and 4He X-ray measurements in SIDDHARTA

The strong-interaction shift of kaonic 3He and 4He 2p states was measured using gaseous targets for the first time in the SIDDHARTA experiment. The determined shift of kaonic 4He is much smaller than the values obtained in the experiments performed in 70's and 80's. Thus, the problems in kaonic helium (the "kaonic helium puzzle") was definitely solved by our measurements. The first observation of the kaonic 3He X-rays was also achieved. The shift both of kaonic 3He and 4He was found to be as small as a few eV.

nucl-ex↗