SearcharxivSearch

arXiv subjects

M. Polo

Publications and source records attributed to M. Polo.

6 recordsLinked to original sources

HASPIDE-SPACE: a new concept of a radiation-resistant instrument for solar energetic particles

Galactic cosmic rays and solar energetic particles (SEPs) affect the performance of instruments carried on board space missions and are the source of the absorbed dose to astronauts. Particles above 100 MeV are the most penetrating. The overall particle flux impacting spacecraft increases by several orders of magnitude during the most intense SEP events and gamma-ray bursts, compared to the galactic cosmic-ray background. Unfortunately, most detectors dedicated to the monitoring of solar particles in space do not allow measurements above 200 MeV. Space agencies and the space and heliospheric weather communities are interested in improving this scenario. We propose a new, compact, low-power, and radiation-resistant instrument, intended for long-duration missions to monitor solar X-rays, electrons, and protons up to energies of tens of keV, MeV, and 600 MeV, respectively. Intense long and short gamma-ray bursts would be observed in the absence of solar activity.

hep-ex

Performance of MAGIC stellar intensity interferometer and expansion to MAGIC + CTAO-LST1 stellar intensity interferometer

A new generation of optical intensity interferometers are emerging in recent years taking advantage of the existing infrastructure of Imaging Atmospheric Cherenkov Telescopes (IACTs). The MAGIC SII (Stellar Intensity Interferometer) in La Palma, Spain, has been operating since its first successful measurements in 2019 and its current design allows it to operate regularly. The current setup is ready to follow up on bright optical transients, as changing from regular gamma-ray observations to SII mode can be done in a matter of minutes. A paper studying the system performance, first measurements and future upgrades has been recently published. MAGIC SII's first scientific results are the measurement of the angular size of 22 stars, 13 of which with no previous measurements in the B band. More recently the Large Sized Telescope prototype from the Cherenkov Telescope Array Observatory (CTAOLST1) has been upgraded to operate together with MAGIC as a SII, leading to its first correlation measurements at the beginning of 2024. MAGIC+CTAO-LST1 SII will be further upgraded by adding the remaining CTAOLSTs at the north site to the system (which are foreseen to be built by the end of 2025). MAGIC+CTAO-LST1 SII shows a feasible technical solution to extend SII to the whole CTAO.

astro-ph.IM

Proton irradiation on Hydrogenated Amorphous Silicon flexible devices

Radiation damage tests in hydrogenated amorphous silicon (a-Si:H) flexible flux and dose-measuring devices have been performed with a 3 MeV proton beam, to evaluate combined displacement and total ionizing dose damage. The tested devices had two different configurations and thicknesses. The first device was a 2 um thick n-i-p diode having a 5 mm x 5 mm area. The second device was a 5 um thick charge selective contact detector having the same area. Both the devices were deposited on a flexible polyimide substrate and were irradiated up to the fluence of 1016 neq/cm2. The response to different proton fluxes has been measured before irradiation and after irradiation at 1016 neq/cm2 for charge-selective contacts and n-i-p devices. The effect of annealing for partial performance recovery at 100{\deg}C for 12 hours was also studied and a final characterization on annealed devices was performed. This test is the first combined displacement and total ionizing dose test on flexible a-Si:H devices.

physics.ins-det

First measurements and upgrade plans of the MAGIC intensity interferometer

The two MAGIC 17-m diameter Imaging Atmospheric Cherenkov Telescopes have been equipped to work also as an intensity interferometer with a deadtime-free, 4-channel, GPU-based, real-time correlator. Operating with baselines between approx. 40 and 90 m the MAGIC interferometer is able to measure stellar diameters of 0.5-1 mas in the 400-440 nm wavelength range with a sensitivity roughly 10 times better than that achieved in the 1970s by the Narrabri Stellar Intensity Interferometer. Besides, active mirror control allows to split the primary mirrors into sub-mirrors. This allows to make simultaneous calibration measurements of the zero-baseline correlation or to simultaneously collect six baselines below 17 m with almost arbitrary orientation, corresponding to angular scales of approx. 1-50 mas. We plan to perform test observations adding the nearby Cherenkov Telescope Array (CTA) LST-1 23 m diameter telescope by next year. All three telescope pairs will be correlated simultaneously. Adding LST-1 is expected to increase the sensitivity by at least 1 mag and significantly improve the u-v plane coverage. If successful, the proposed correlator setup is scalable enough to be implemented to the full CTA arrays.

astro-ph.IM

Commissioning of the camera of the first Large Size Telescope of the Cherenkov Telescope Array

The first Large Size Telescope (LST-1) of the Cherenkov Telescope Array has been operational since October 2018 at La Palma, Spain. We report on the results obtained during the camera commissioning. The noise level of the readout is determined as a 0.2 p.e. level. The gain of PMTs are well equalized within 2\% variation, using the calibration flash system. The effect of the night sky background on the signal readout noise as well as the PMT gain estimation are also well evaluated. Trigger thresholds are optimized for the lowest possible gamma-ray energy threshold and the trigger distribution synchronization has been achieved within 1~ns precision. Automatic rate control realizes the stable observation with 1.5\% rate variation over 3 hours. The performance of the novel DAQ system demonstrates a less than 10\% dead time for 15 kHz trigger rate even with sophisticated online data correction.

astro-ph.IM

Optical intensity interferometry observations using the MAGIC imaging atmospheric Cherenkov telescopes

Imaging Atmospheric Cherenkov Telescopes (IACTs) currently in operation feature large mirrors and order of 1 ns time response to signals of a few photo-electrons produced by optical photons. This means that they are ideally suited for optical interferometry observations. Thanks to their sensitivity to visible wavelengths and long baselines optical intensity interferometry with IACTs allows reaching angular resolutions of tens to microarcsec. We have installed a simple optical setup on top of the cameras of the two 17 m diameter MAGIC IACTs and observed coherent fluctuations in the photon intensity measured at the two telescopes for three different stars. The sensitivity is roughly 10 times better than that achieved in the 1970s with the Narrabri interferometer.

astro-ph.IM