SearcharxivSearch

arXiv subjects

M. Proga

Publications and source records attributed to M. Proga.

At least 19 recordsLinked to original sources

Optical characterization and ionizing-radiation response of the BCF-20XL scintillating-wavelength-shifting fiber

We report optical characterization and ionizing-radiation measurements of the scintillating-wavelength-shifting (Sci-WLS) fiber BCF-20XL from Luxium Solutions. Attenuation lengths were obtained from transmitted emission spectra using a 3.0 m fiber with a spectrophotometer and described with a two-component attenuation model, yielding a long attenuation length of 6.70 m and a short attenuation length of 0.16 m. The spectral measurements also reveal wavelength-dependent attenuation, with the long component increasing with wavelength and the short component becoming less significant at longer wavelengths. The scintillation response was also characterized under radioactive alpha, beta, and gamma irradiation using SiPM-based readout, providing a benchmark measurement of the light output from BCF-20XL.

physics.ins-det

Response of wavelength-shifting and scintillating-wavelength-shifting fibers to ionizing radiation

We report results of characterizing the response and light transport of wavelength-shifting (WLS) and scintillating-wavelength-shifting (Sci-WLS) fibers under irradiation by radioactive $\alpha$, $\beta$, and $\gamma$ sources. Light yield and light transmission were measured for the WLS fiber BCF-91A from Saint-Gobain and for a new Sci-WLS fiber EJ-160 from Eljen Technology. The two variants with different fluor mixtures, EJ-160I and EJ-160II, exhibited approximately five and seven times higher light yield than BCF-91A, respectively, while their attenuation lengths were 3.80\,m for BCF-91A, 4.00\,m for EJ-160I, and 2.50\,m for EJ-160II.

physics.ins-det

Optical characterization of wavelength-shifting and scintillating-wavelength-shifting fibers

We report results of optical characterizations of new wavelength-shifting and scintillating-wavelength-shifting fibers EJ-182 and EJ-160 from Eljen Technology and compare them to the wavelength-shifting fiber BCF-91A from Saint-Gobain. The wavelength-dependence of attenuation was derived from spectral measurements confirming that the long attenuation length increases with wavelength, while short attenuation effects become less significant at longer wavelengths. The impact of the environmental refractive index was studied by immersing the EJ-160II fiber in water. Immersing the fiber in water reduced the overall light output and suppressed the short attenuation component, which can be explained by reduced light-collection efficiency due to the smaller refractive-index contrast between the fiber cladding and the surrounding medium.

physics.ins-det

Fabrication of thin planar radiopure foils with 82Se for the SuperNEMO Demonstrator

The SuperNEMO Demonstrator, designed to search for double beta decay using enriched 82Se, has been assembled in the Modane Underground Laboratory under the French Alps. Thin foils with radio - purified and enriched 82Se are installed centrally in the detector. A novel foil fabrication method has been developed, improving the radiopurity achieved in the previous generation experiment. It consists of wrapping standalone selenium pads in raw Mylar, combined with selenium purified by a new reverse-chromatography method. This paper describes the features of these foils, their fabrication process, the characterization results, and the integration of the foils into the SuperNEMO Demonstrator.

physics.ins-det

The Impact of Helium Exposure on the PMTs of the SuperNEMO Experiment

The performance of Hamamatsu 8" photomultiplier tubes (PMTs) of the type used in the SuperNEMO neutrinoless double-beta decay experiment (R5912-MOD), is investigated as a function of exposure to helium (He) gas. Two PMTs were monitored for over a year, one exposed to varying concentrations of He, and the other kept in standard atmospheric conditions as a control. Both PMTs were exposed to light signals generated by a Bi-207 radioactive source that provided consistent large input PMT signals similar to those that are typical of the SuperNEMO experiment. The energy resolution of PMT signals corresponding to 1 MeV energy scale determined from the Bi-207 decay spectrum, shows a negligible degradation with He exposure; however the rate of after-pulsing shows a clear increase with He exposure, which is modelled and compared to diffusion theory. A method for reconstructing the partial pressure of He within the PMT and a method for determining the He breakdown point, are introduced. The implications for long-term SuperNEMO operations are briefly discussed.

physics.ins-det

Calorimeter commissioning of the SuperNEMO Demonstrator

The SuperNEMO experiment is searching for neutrinoless double beta decay of \textsuperscript{82}Se, with the unique combination of a tracking detector and a segmented calorimeter. This feature allows to detect the two electrons emitted in the decay and measure their individual energy and angular distribution. The SuperNEMO calorimeter consists of 712 plastic scintillator blocks readout by large PMTs. After the construction of the demonstrator calorimeter underground, we have performed its first commissioning using $\gamma$-particles from calibration sources or from the ambient radioactive background. This article presents the quality assurance tests of the SuperNEMO demonstrator calorimeter and its first time and energy calibrations, with the associated methods.

physics.ins-det

Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO

The SuperNEMO experiment will search for neutrinoless double-beta decay ($0\nu\beta\beta$), and study the Standard-Model double-beta decay process ($2\nu\beta\beta$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($\beta\beta$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly. The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.

physics.ins-det

EMPHATIC: A proposed experiment to measure hadron scattering and productioncross sections for improved neutrino flux predictions

Hadron scattering and production uncertainties are a limiting systematic on accelerator and at-mospheric neutrino flux predictions. New hadron measurements are necessary for neutrino fluxpredictions with well-understood and reduced uncertainties. We propose a new compact experimentto measure hadron scattering and production cross sections at beam energies that are inaccessibleto currently operating experiments. These measurements can reduce the current 10% neutrino fluxuncertainties by an approximate factor of two.

hep-ex

Spectral Characterization and Modeling of Wavelength-shifting Fibers

We have constructed a detailed software model of photon transport in clear and wavelength shifting polystyrene optical fibers based on the GEANT4 framework. We validate the model with measurements obtained from several different lengths of fiber illuminated with several LEDs, using two independent acquisition systems. The simulated spectral and spatial light distributions at the end of the fiber and the resultant attenuation lengths show good agreement with measurement. We use the model to predict the fiber behaviour for several test cases and discuss potential applications.

physics.ins-det

Background Studies for the MINER Coherent Neutrino Scattering Reactor Experiment

The proposed Mitchell Institute Neutrino Experiment at Reactor (MINER) experiment at the Nuclear Science Center at Texas A&M University will search for coherent elastic neutrino-nucleus scattering within close proximity (about 2 meters) of a 1 MW TRIGA nuclear reactor core using low threshold, cryogenic germanium and silicon detectors. Given the Standard Model cross section of the scattering process and the proposed experimental proximity to the reactor, as many as 5 to 20 events/kg/day are expected. We discuss the status of preliminary measurements to characterize the main backgrounds for the proposed experiment. Both in situ measurements at the experimental site and simulations using the MCNP and GEANT4 codes are described. A strategy for monitoring backgrounds during data taking is briefly discussed.

physics.ins-det

CHerenkov detectors In mine PitS (CHIPS) Letter of Intent to FNAL

This Letter of Intent outlines a proposal to build a large, yet cost-effective, 100 kton fiducial mass water Cherenkov detector that will initially run in the NuMI beam line. The CHIPS detector (CHerenkov detector In Mine PitS) will be deployed in a flooded mine pit, removing the necessity and expense of a substantial external structure capable of supporting a large detector mass. There are a number of mine pits in northern Minnesota along the NuMI beam that could be used to deploy such a detector. In particular, the Wentworth Pit 2W is at the ideal off-axis angle to contribute to the measurement of the CP violating phase. The detector is designed so that it can be moved to a mine pit in the LBNE beam line once that becomes operational.

physics.ins-det

Secondary Beam Monitors for the NuMI Facility at FNAL

The Neutrinos at the Main Injector (NuMI) facility is a conventional neutrino beam which produces muon neutrinos by focusing a beam of mesons into a long evacuated decay volume. We have built four arrays of ionization chambers to monitor the position and intensity of the hadron and muon beams associated with neutrino production at locations downstream of the decay volume. This article describes the chambers' construction, calibration, and commissioning in the beam.

physics.ins-det

Beam Test of a Segmented Foil SEM Grid

A prototype Secondary-electron Emission Monitor (SEM) was installed in the 8 GeV proton transport line for the MiniBooNE experiment at Fermilab. The SEM is a segmented grid made with 5 um Ti foils, intended for use in the 120 GeV NuMI beam at Fermilab. Similar to previous workers, we found that the full collection of the secondary electron signal requires a bias voltage to draw the ejected electrons cleanly off the foils, and this effect is more pronounced at larger beam intensity. The beam centroid and width resolutions of the SEM were measured at beam widths of 3, 7, and 8 mm, and compared to calculations. Extrapolating the data from this beam test, we expect a centroid and width resolutions of 20um and 25 um, respectively, in the NuMI beam which has 1 mm spot size.

physics.ins-det

Segmented Foil SEM Grids at Fermilab

We present recent beam data from a new design of a profile monitor for proton beams at Fermilab. The monitors, consisting of grids of segmented Ti foils 5micrometers thick, are secondary-electron emission monitors (SEM's). We review data on the device's precision on beam centroid position, beam width, and on beam loss associated with the SEM material placed in the beam.

physics.ins-det

Ion Chamber Arrays for the Numi Beam at Fermilab

The Neutrinos at the Main Injector (NuMI) beamline will deliver an intense muon neutrino beam by focusing a beam of mesons into a long evacuated decay volume. We have built 4 arrays of ionization chambers to monitor the neutrino beam direction and quality. The arrays are located at 4 stations downstream of the decay volume, and measure the remnant hadron beam and tertiary muons produced along with neutrinos in meson decays.

physics.ins-det

Study of Neutron-Induced Ionization in Helium and Argon Chamber Gases

Ion chambers used to monitor the secondary hadron and tertiary muon beam in the NuMI neutrino beamline will be exposed to background particles, including low energy neutrons produced in the beam dump. To understand these backgrounds, we have studied Helium- and Argon-filled ionization chambers exposed to intense neutron fluxes from PuBe neutron sources ($E_n=1-10$ MeV). The sources emit about 10$^8$ neutrons per second. The number of ion pairs in the chamber gas volume per incident neutron is derived. While limited in precision because of a large gamma ray background from the PuBe sources, our results are consistent with the expectation that the neutrons interact purely elastically in the chamber gas.

physics.ins-det

Ion Chambers for Monitoring the NuMI Neutrino Beam at FNAL

The Neutrinos at the Main Injector (NuMI) beamline will deliver an intense muon neutrino beam by focusing a beam of mesons into a long evacuated decay volume. The beam must be steered with 1 mRad angular accuracy toward the Soudan Underground Laboratory in northern Minnesota. We have built 4 arrays of ionization chambers to monitor the neutrino beam direction and quality. The arrays are located at 4 stations downstream of the decay volume, and measure the remnant hadron beam and tertiary muons produced along with neutrinos in meson decays. We review how the monitors will be used to make beam quality measurements, and as well we review chamber construction details, radiation damage testing, calibration, and test beam results.

physics.acc-ph

Profile Monitor SEM's for the NuMI Beam at FNAL

The Neutrinos at the Main Injector (NuMI) project will extract 120 GeV protons from the FNAL Main Injector in 8.56usec spills of 4E13 protons every 1.9 sec. We have designed secondary emission monitor (SEM) detectors to measure beam profile and halo along the proton beam transport line. The SEM?s are Ti foils 5um in thickness segmented in either 1?mm or 0.5?mm pitch strips, resulting in beam loss ~5E-6. We discuss aspects of the mechanical design, calculations of expected beam heating, and results of a beam test at the 8 GeV transport line to MiniBoone at FNAL.

physics.acc-ph