Searcharxiv⌕ Search

arXiv subjects

M. R. Dutta Majumdar

Publications and source records attributed to M. R. Dutta Majumdar.

4 recordsLinked to original sources

Full Spectrum Diffused and Beamed Solar Energy Application Using Optical Fibre

Existing solar energy application systems use small fraction of full spectrum of solar energy. So attempts are made to show how full spectrum solar energy can be used for diffused and beamed form of incident solar energy. Luminescent Solar Concentrator (LSC) principle with optical fibre in diffused sun light and dielectric mirror separation technique with optical fibre in beamed form are discussed. Comparison of both the cases are done. Keywords: full spectrum, solar photonics, diffused solar energy, beamed solar energy, LSC, dielectric mirror, optical fibre, Photo-Voltaic

physics.optics↗

Opto-Electronics in Large Array Gas Detector Systems

Large array gas detector systems are used in particle and nuclear physics experiments involving high-energy nucleon-nucleon and heavy-ion collisions. We have observed that in large array gas detector systems the momentary discharges inside the detector cells result in slowdown of High Voltage conditioning and possible hindrances in signal processing. We have explored the opto-electronic devices like the opto-coupler, optical fibre and signal processing circuit, which provide successful monitoring procedures and preventive measures to overcome the challenges produced in such complex detector systems.

physics.ins-det↗

A Honeycomb Proportional Counter for Photon Multiplicity Measurement in the ALICE Experiment

A honeycomb detector consisting of a matrix of 96 closely packed hexagonal cells, each working as a proportional counter with a wire readout, was fabricated and tested at the CERN PS. The cell depth and the radial dimensions of the cell were small, in the range of 5-10 mm. The appropriate cell design was arrived at using GARFIELD simulations. Two geometries are described illustrating the effect of field shaping. The charged particle detection efficiency and the preshower characteristics have been studied using pion and electron beams. Average charged particle detection efficiency was found to be 98%, which is almost uniform within the cell volume and also within the array. The preshower data show that the transverse size of the shower is in close agreement with the results of simulations for a range of energies and converter thicknesses.

nucl-ex↗

A Preshower Photon Multiplicity Detector for the WA98 Experiment

A high granularity preshower detector has been fabricated and installed in the WA98 Experiment at the CERN SPS for measuring the spatial distribution of photons produced in the forward region in lead ion induced interactions. Photons are counted by detecting the preshower signal in plastic scintillator pads placed behind a 3 radiation length thick lead converter and applying a threshold on the scintillator signal to reject the minimum ionizing particles. Techniques to improve the imaging of the fibre and performance of the detector in the high multiplicity environment of lead-lead collisions are described. Using Monte-Carlo simulation methods and test beam data of pi- and e- at various energies the photon counting efficiency is estimated to be 68% for central and 73% for peripheral Pb+Pb collisions.

hep-ex↗