Searcharxiv⌕ Search

arXiv subjects

M. R. Vissers

Publications and source records attributed to M. R. Vissers.

At least 19 recordsLinked to original sources

A microwave SQUID multiplexing concept for macro-cryogenic calorimeter arrays

Massive cryogenic calorimeters read out by transition-edge sensors (TES) can reach eV-scale baseline resolution, but the single-channel dc-SQUID readout conventionally used in rare-event searches, with one amplifier chain and several wires per detector, limits practical arrays to a few tens of channels. We propose to apply microwave SQUID multiplexing ($μ$MUX), developed for fast X-ray and neutrino-mass microcalorimeters, to massive BGO (Bi$_4$Ge$_3$O$_{12}$) calorimeters operated at $\simeq 20$~mK; sapphire and TeO$_2$ absorbers are covered by the same framework. Using the established thermal and noise model for massive TES calorimeters, we derive a noise model for the multiplexed readout, including the HEMT, two-level-system and SQUID contributions, and its scaling with the multiplexing factor $N_{\rm mux}$. Since the slow thermal signals require only about a kHz of sampling per channel, the limiting requirement is not bandwidth but an input-coil sensitivity of $( 0.1$ to $1)\,μ$A$/Φ_0$, a factor of $10$ to $30$ beyond current $μ$MUX devices, matched to the detector current noise of ($9$ to $10$)~pA$/\sqrt{\rm Hz}$, which is independent of the absorber mass. With a total flux noise of $\simeq$$1.2\,μΦ_0/\sqrt{\rm Hz}$, the readout degrades the baseline resolution by less than $2\%$ up to $N_{\rm mux}=1000$, negligible compared with the TES-limited resolution. These results are implemented in a single-tower design: 52 BGO crystals of 100~g each and one HEMT amplifier. The tower is the unit of a multi-tower array of several kilograms aimed at CE$ν$NS and dark matter searches.

physics.ins-det↗

The SPT-3G+ receiver design

We present the thermo-mechanical design of the cryostat and camera optics for SPT-3G+, a new receiver being developed for the South Pole Telescope (SPT). The receiver consists of 14 detector arrays of 90/150 GHz dichroic polarization-sensitive pixels, totaling 24,080 transition-edge sensor detectors. Each detector array lies at the end of an optics tube, each approximately 240 mm in diameter and 772 mm in length, which are arranged in a hexagonal close-packed configuration to achieve a 4 degree diameter field of view. Each optics tube contains four anti-reflection coated lenses fabricated from different materials (alumina, silicon, and nylon) that are designed to also provide infrared filtering that reduces the radiative loading on the cryogenic stages. The optics and detectors are cooled by a combination of a pulse tube cooler for the 40 K and 4 K stages, and a dilution refrigerator for the 1 K and 100 mK stages. Thermal modeling predicts the heat load to be less than 26 W and 1 W for the 40 K and 4 K stages, respectively. The 1,550 kg cryostat has a 1.1 meter diameter at the vacuum window, which is located near the telescope Gregorian focus, and 1.75 meters in height and length. Fabrication of the cryostat will begin in 2026, with installation on the SPT scheduled for the 2028-29 austral summer, ahead of the 2029 winter observing season.

astro-ph.IM↗

SPT-3G+: A Cosmic Microwave Background Experiment for the South Pole Telescope

SPT-3G+ is the next survey receiver planned to be installed in early 2029 on the 10-meter South Pole Telescope (SPT). This new receiver will feature 6,020 polarization-sensitive dichroic pixels with transition-edge sensors observing in frequency bands centered at 90 GHz and 150 GHz. The 24,080 detectors in the SPT-3G+ receiver will be cooled to 100 mK by a dilution refrigerator and read out using microwave SQUID multiplexing. The optical design of the receiver enables a 4 degree diameter field of view, which is broken up into 14 individual optics tubes each containing cryogenic alumina, silicon, and nylon lenses. These technology choices will allow the SPT-3G+ receiver to improve on the mapping speed of the currently operating SPT-3G receiver by nearly an order of magnitude. Once deployed, the SPT-3G+ receiver will observe for 6-years an area overlapping with the BICEP survey to achieve a combined (90 GHz and 150 GHz) CMB map depth of 0.5 uK-arcmin. Data from these observations will be used to create unprecedentedly deep CMB lensing maps, discover new galaxy clusters, and detect astrophysical transients. The lensing map produced by SPT-3G+ will be used to remove or "delens" foreground B modes, where large-scale structure gravitationally lenses the CMB and converts E modes into B-mode polarization, with the goal of revealing inflationary B modes. Together with data from the BICEP Array as part of the South Pole Observatory, SPT-3G+ data will be used to constrain the tensor-to-scalar ratio $r$ with a goal of achieving a measurement of $σ(r) = 0.001$

astro-ph.CO↗

In-Flight Performance of Spider's 280 GHz Receivers

SPIDER is a balloon-borne instrument designed to map the cosmic microwave background at degree-angular scales in the presence of Galactic foregrounds. SPIDER has mapped a large sky area in the Southern Hemisphere using more than 2000 transition-edge sensors (TESs) during two NASA Long Duration Balloon flights above the Antarctic continent. During its first flight in January 2015, SPIDER observed in the 95 GHz and 150 GHz frequency bands, setting constraints on the B-mode signature of primordial gravitational waves. Its second flight in the 2022-2023 season added new receivers at 280 GHz, each using an array of TESs coupled to the sky through feedhorns formed from stacks of silicon wafers. These receivers are optimized to produce deep maps of polarized Galactic dust emission over a large sky area, providing a unique data set with lasting value to the field. We describe the instrument's performance during SPIDER's second flight, focusing on the performance of the 280 GHz receivers. We include details on the flight, in-band optical loading at float, and an early analysis of detector noise.

astro-ph.IM↗

Measurable Improvement in Multi-Qubit Readout Using a Kinetic Inductance Traveling Wave Parametric Amplifier

Increasing the size and complexity of quantum information systems requires highly-multiplexed readout architectures, as well as amplifier chains operating near the quantum limit (QL) of added noise. While documented prior efforts in KITWPA integration in quantum systems are scarce, in this work we demonstrate integration of a KI-TWPA with a multiplexed-qubit device. To quantify the system noise improvement we perform an ac Stark shift calibration to precisely determine noise power levels on-chip (at each cavity's reference plane) and the total system gain. We then characterize the qubit state measurement fidelity and the corresponding signal-to-noise ratio (SNR). To conduct the most faithful measurement of the benefits offered by the KI-TWPA we perform these measurements for readout chains where the high electron mobility transistor (HEMT) amplifier is the first-stage amplifier (FSA) - with none of the external hardware required to operate the KI-TWPA - and with the KI-TWPA as the FSA. While some readout cavities fall outside the KI-TWPA bandwidth, for those inside the bandwidth we demonstrate a maximum improvement in the state measurement SNR by a factor of 1.45, and increase the fidelity from 96.2% to 97.8%. These measurements demonstrate a system noise below 5 quanta referenced on-chip and we bound the KI-TWPA excess noise to be below 4 quanta for the six cavities inside its bandwidth. These results show a promising path forward for realizing quantum-limited readout chains in large qubit systems using a single parametric amplifier.

quant-ph↗

Characterization of NbTiN films with thicknesses below 20 nm for low power kinetic inductance amplifiers

A quantum-limited amplification chain is a fundamental advantage for any application that may benefit from the detection of very faint signals. Reading out arrays of superconducting detectors (TESs or MKIDs), resonant cavities, or qubits, calls for large bandwidth amplifiers in addition to having the lowest possible noise. At millikelvin temperatures, Kinetic Inductance Traveling-Wave Parametric Amplifiers (KI-TWPAs) working in 3-wave-mixing (3WM) and fabricated from a 20 nm thick NbTiN film have shown promising noise performances, as they can operate close to the quantum limit. However, they still require fairly high pump power. Devices that would require lower pump power would be easier to implement in readout chains, could reach the quantum limit and they would be compatible with qubit readout. A possible solution for obtaining this optimal configuration is to use a thinner superconducting film. In this work we explore the properties of NbTiN films with a thickness less than 20 nm and we report the obtained experimental characterizations in terms of critical temperature, normal resistivity, and kinetic inductance. A new design for a 3WM KI-TWPA amplifier, based on these developed superconducting films, is introduced and discussed.

cond-mat.supr-con↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from $1.6$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA off, to $0.77$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA on. When statically biasing the umux to the maximally flux-sensitive point, the flux noise drops from $0.45$ $μΦ_0/\sqrt{\mathrm{Hz}}$ to $0.2$ $μΦ_0/\sqrt{\mathrm{Hz}}$. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the umux and detecting background radiation. The combination of umux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

astro-ph.IM↗

G4CMP: Condensed Matter Physics Simulation Using the Geant4 Toolkit

G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as electron and hole charge carriers. Processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reproduces theoretical predictions and experimental observations such as phonon caustics, heat-pulse propagation times, and mean charge-carrier drift velocities. In addition to presenting the physics and features supported by G4CMP, this report outlines example applications from the dark matter and quantum information science communities. These communities are applying G4CMP to model and design devices for which the energy transported by phonons and charge carriers is germane to the performance of superconducting instruments and circuits placed on silicon and germanium substrates. The G4CMP package is available to download from GitHub: github.com/kelseymh/G4CMP.

hep-ex↗

CCAT-prime Collaboration: Science Goals and Forecasts with Prime-Cam on the Fred Young Submillimeter Telescope

We present a detailed overview of the science goals and predictions for the Prime-Cam direct detection camera/spectrometer being constructed by the CCAT-prime collaboration for dedicated use on the Fred Young Submillimeter Telescope (FYST). The FYST is a wide-field, 6-m aperture submillimeter telescope being built (first light in mid-2024) by an international consortium of institutions led by Cornell University and sited at more than 5600 meters on Cerro Chajnantor in northern Chile. Prime-Cam is one of two instruments planned for FYST and will provide unprecedented spectroscopic and broadband measurement capabilities to address important astrophysical questions ranging from Big Bang cosmology through reionization and the formation of the first galaxies to star formation within our own Milky Way galaxy. Prime-Cam on the FYST will have a mapping speed that is over ten times greater than existing and near-term facilities for high-redshift science and broadband polarimetric imaging at frequencies above 300 GHz. We describe details of the science program enabled by this system and our preliminary survey strategies.

astro-ph.CO↗

Performance of a Kinetic-Inductance Traveling-Wave Parametric Amplifier at 4 Kelvin: Toward an Alternative to Semiconductor Amplifiers

Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable noise performance, a conventional HEMT dissipates several milliwatts of power, posing a practical challenge to scale up the number of qubits or sensors addressed in these architectures. As an alternative, we present an amplification chain consisting of a kinetic-inductance traveling-wave parametric amplifier (KI-TWPA) placed at 4 K, followed by a HEMT placed at 70 K, and demonstrate a chain-added noise $T_Σ= 6.3\pm0.5$ K between 3.5 and 5.5 GHz. While, in principle, any parametric amplifier can be quantum limited even at 4 K, in practice we find the KI-TWPA's performance limited by the temperature of its inputs, and by an excess of noise $T_\mathrm{ex} = 1.9$ K. The dissipation of the KI-TWPA's rf pump constitutes the main power load at 4 K and is about one percent that of a HEMT. These combined noise and power dissipation values pave the way for the KI-TWPA's use as a replacement for semiconductor amplifiers.

quant-ph↗

Study of quasi-particle dynamics using the optical pulse response of asuperconducting resonator

We study the optical pulse response of a superconducting half-wavelength coplanar waveguide (CPW) resonator. We apply a short optical pulse to the center strip of the CPW resonator, where the current distribution shows antinodes or nodes for different resonance modes, and measure the frequency response. We develop a time-dependent variable inductance circuit model with which we can simulate the optical pulse response of the resonator. By fitting this model to experimental data, we extract the temporal kinetic inductance variations, which directly reflect the quasi-particle recombination with time and diffusion in space. We also retrieve the spatial size of the quasi-particle distribution and the quasi-particle diffusion constant. Our study is very useful for the design of photon-counting kinetic inductance detectors, and the method developed in this work provides a useful way to study the quasi-particle dynamics in the superconductor.

cond-mat.supr-con↗

Design and pre-flight performance of SPIDER 280 GHz receivers

In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for the second Antarctic flight will incorporate three new 280 GHz receivers alongside three refurbished 95- and 150 GHz receivers from Spider's first flight. In this work we discuss the design and characterization of these new receivers, which employ over 1500 feedhorn-coupled transition-edge sensors. We describe pre-flight laboratory measurements of detector properties, and the optical performance of completed receivers. These receivers will map a wide area of the sky at 280 GHz, providing new information on polarized Galactic dust emission that will help to separate it from the cosmological signal.

astro-ph.IM↗

Sub-Kelvin Thermometer for On-Chip Measurements of Microwave Devices Utilizing Two-Level Systems in Superconducting Microresonators

We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the sensitivity (50-75~$μ$K/$\sqrt{\mathrm{Hz}}$) is relatively uniform across this range. The miniature footprint that conveniently attaches to the feedline of a cryogenic microwave device facilitates the measurement of on-chip device temperature and requires no additional thermometry wiring or readout electronics. We demonstrate the practical use of these TLS thermometers to investigate static and transient chip heating in a kinetic inductance traveling-wave parametric amplifier operated with a strong pump tone. TLS thermometry may find broad application in cryogenic microwave devices such as superconducting qubits and detectors.

physics.ins-det↗

A three-wave mixing kinetic inductance traveling-wave amplifier with near-quantum-limited noise performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave amplifier (KIT), whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, the KIT operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT devices. It consists of a 50 Ohms artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{-1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of -63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT, we measure the system-added noise of an amplification chain that integrates the KIT as the first amplifier. This system-added noise, $3.1\pm0.6$ quanta (equivalent to $0.66\pm0.15$ K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

quant-ph↗

Millimeter-Wave Polarimeters Using Kinetic Inductance Detectors for TolTEC and Beyond

Microwave Kinetic Inductance Detectors (MKIDs) provide a compelling path forward to the large-format polarimeter, imaging, and spectrometer arrays needed for next-generation experiments in millimeter-wave cosmology and astronomy. We describe the development of feedhorn-coupled MKID detectors for the TolTEC millimeter-wave imaging polarimeter being constructed for the 50-meter Large Millimeter Telescope (LMT). Observations with TolTEC are planned to begin in early 2019. TolTEC will comprise $\sim$7,000 polarization sensitive MKIDs and will represent the first MKID arrays fabricated and deployed on monolithic 150 mm diameter silicon wafers -- a critical step towards future large-scale experiments with over $10^5$ detectors. TolTEC will operate in observational bands at 1.1, 1.4, and 2.0 mm and will use dichroic filters to define a physically independent focal plane for each passband, thus allowing the polarimeters to use simple, direct-absorption inductive structures that are impedance matched to incident radiation. This work is part of a larger program at NIST-Boulder to develop MKID-based detector technologies for use over a wide range of photon energies spanning millimeter-waves to X-rays. We present the detailed pixel layout and describe the methods, tools, and flexible design parameters that allow this solution to be optimized for use anywhere in the millimeter and sub-millimeter bands. We also present measurements of prototype devices operating in the 1.1 mm band and compare the observed optical performance to that predicted from models and simulations.

astro-ph.IM↗

Measurement of optical constants of TiN and TiN/Ti/TiN multilayer films for microwave kinetic inductance photon-number-resolving detectors

We deposit thin titanium-nitride (TiN) and TiN/Ti/TiN multilayer films on sapphire substrates and measure the reflectance and transmittance in the wavelength range from 400 nm to 2000 nm using a spectrophotometer. The optical constants (complex refractive indices), including the refractive index n and the extinction coefficient k, have been derived. With the extracted refractive indices, we propose an optical stack structure using low-loss amorphous Si (a-Si) anti-reflective coating and a backside aluminum (Al) reflecting mirror, which can in theory achieve 100% photon absorption at 1550 nm. The proposed optical design shows great promise in enhancing the optical efficiency of TiN-based microwave kinetic inductance photon-number-resolving detectors.

physics.optics↗

280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter

We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.

astro-ph.IM↗

Superconducting micro-resonator arrays with ideal frequency spacing and extremely low frequency collision rate

We present a wafer trimming technique for producing superconducting micro-resonator arrays with highly uniform frequency spacing. With the light-emitting diode (LED) mapper technique demonstrated previously, we first map the measured resonance frequencies to the physical resonators. Then, we fine-tune each resonator's frequency by lithographically trimming a small length, calculated from the deviation of the measured frequency from its design value, from the interdigitated capacitor. We demonstrate this technique on a 127-resonator array made of titanium-nitride (TiN) and show that the uniformity of frequency spacing is greatly improved. The array yield in terms of frequency collisions improves from 84% to 97%, while the quality factors and noise properties are unaffected. The wafer trimming technique provides an easy-to-implement tool to improve the yield and multiplexing density of large resonator arrays, which is important for various applications in photon detection and quantum computing.

physics.ins-det↗