High-frequency corrections to the detector response and their effect on searches for gravitational waves

Searches for gravitational waves with km-scale laser interferometers often involve the long-wavelength approximation to describe the detector response. The prevailing assumption is that the corrections to the detector response due to its finite size are small and the errors due to the long-wavelength approximation are negligible. Recently, however, Baskaran and Grishchuk (2004 Class. Quantum Grav. 21 4041) found that in a simple Michelson interferometer such errors can be as large as 10 percent. For more accurate analysis, these authors proposed to use a linear-frequency correction to the long wavelength approximation. In this paper we revisit these calculations. We show that the linear-frequency correction is inadequate for certain locations in the sky and therefore accurate analysis requires taking into account the exact formula, commonly derived from the photon round-trip propagation time. Also, we extend the calculations to include the effect of Fabry-Perot resonators in the interferometer arms. Here we show that a simple approximation which combines the long-wavelength Michelson response with the single-pole approximation to the Fabry-Perot transfer function produces rather accurate results. In particular, the difference between the exact and the approximate formulae is at most 2-3 percent for those locations in the sky where the detector response is greater than half of its maximum value. We analyse the impact of such errors on detection sensitivity and parameter estimation in searches for periodic gravitational waves emitted by a known pulsar, and in searches for an isotropic stochastic gravitational-wave background. At frequencies up to 1 kHz, the effect of such errors is at most 1-2 percent. For higher frequencies, or if more accuracy is required, one should use the exact formula for the response.

gr-qc

Constraint Likelihood analysis for a network of gravitational wave detectors

We propose a coherent method for the detection and reconstruction of gravitational wave signals for a network of interferometric detectors. The method is derived using the likelihood functional for unknown signal waveforms. In the standard approach, the global maximum of the likelihood over the space of waveforms is used as the detection statistic. We identify a problem with this approach. In the case of an aligned pair of detectors, the detection statistic depends on the cross-correlation between the detectors as expected, but this dependence dissappears even for infinitesimally small misalignments. We solve the problem by applying constraints on thelikelihood functional and obtain a new class of statistics. The resulting method can be applied to the data from a network consisting of any number of detectors with arbitrary detector orientations. The method allows us reconstruction of the source coordinates and the waveforms of two polarization components of a gravitational wave. We study the performance of the method with numerical simulation and find the reconstruction of the source coordinates to be more accurate than in the standard approach.

gr-qc

Dynamic Resonance of Light in Fabry-Perot Cavities

The dynamics of light in Fabry-Perot cavities with varying length and input laser frequency are analyzed and the exact condition for resonance is derived. This dynamic resonance depends on the light transit time in the cavity and the Doppler effect due to the mirror motions. The response of the cavity to length variations is very different from its response to laser frequency variations. If the frequency of these variations is equal to multiples of the cavity free spectral range, the response to length is maximized while the response to the laser frequency is zero. Implications of these results for the detection of gravitational waves using kilometer-scale Fabry-Perot cavities are discussed.

physics.optics

Dynamics of Fabry-Perot resonators with suspended mirrors. I. Nonlinear coupled oscillators

The dynamics of Fabry-Perot cavity with suspended mirrors is described. The suspended mirrors are nonlinear oscillators interacting with each other through the laser circulating in the cavity. The degrees of freedom decouple in normal coordinates, which are the position of the center of mass and the length of the cavity. We introduce two parameters and study how the dynamics changes with respect to these parameters. The first parameter specifies how strong the radiation pressure is. It determines whether the cavity is multistable or not. The second parameter is the control parameter, which determines location of the cavity equilibrium states. The equilibrium state shows hysteresis if the control parameter varies within a wide range. We analyze stability of the equilibrium states and identify the instability region. The instability is explained in terms of the effective potential: the stable states correspond to local minima of the effective potential and unstable states correspond to local maxima. The minima of the effective potential defines the resonant frequencies for the oscillations of the cavity length. We find the frequencies, and analyze how to tune them. Multistability of the cavity with a feedback control system is analyzed in terms of the servo potential. The results obtained in this paper are general and apply to all Fabry-Perot cavities with suspended mirrors.

physics.optics

Optical vernier technique for in-situ measurement of the length of long Fabry-Perot cavities

We propose a method for in-situ measurement of the length of kilometer size Fabry-Perot cavities in laser gravitational wave detectors. The method is based on the vernier, which occurs naturally when the laser incident on the cavity has a sideband. By changing the length of the cavity over several wavelengths we obtain a set of carrier resonances alternating with sideband resonances. From the measurement of the separation between the carrier and a sideband resonance we determine the length of the cavity. We apply the technique to the measurement of the length of a Fabry-Perot cavity in the Caltech 40m Interferometer and discuss the accuracy of the technique.

physics.ins-det