SearcharxivSearch

arXiv subjects

M. Ridder

Publications and source records attributed to M. Ridder.

4 recordsLinked to original sources

AMKID -- a large KID-based camera at the APEX telescope

The thermal emission at sub-millimeter wavelengths carries unique information in many astronomical applications ranging from disks and planet formation around young stars, to galaxy evolution studies at cosmological distances. Advancing on the mapping speed to detect this faint emission in ground-based astronomy has been a technical challenge for decades. The APEX Microwave Kinetic Inductance Detector (AMKID) camera was designed to accomplish this task. The instrument is a wide field-of-view camera based on kinetic inductance detectors. It is installed on the 12~meter APEX telescope in Chile at 5.100~meters above see level. The instrument operates dual color, covering simultaneously the 350~GHz and 850~GHz atmospheric windows. It has a large field-of-view of 15.3'x15.3', and an unprecedented number of pixels: 13.952~detectors in the high frequency band and 3.520~detectors in the low frequency band. Here we present a complete description of the instrument design and construction together with results of the successful low frequency array (LFA) commissioning campaign executed during the last year. The LFA performance is in good agreement with design parameters, with detector sensitivity of 2.2~mK$\sqrt{s}$ and diffraction limited beam sizes of 17.0''. On-sky measurements demonstrate a sensitivity of 70-90~mJy$\sqrt{s}$ per detector when operating under good atmospheric conditions (PWV below 1.0mm). With this performance the LFA regularly achieve a mapping sensitivity of 25~mJy when mapping a square degree in an hour. AMKID on APEX with its dual color observing capabilities, high sensitivity, large field-of-view and high angular resolution holds the promise to open a new range of science with the APEX telescope.

astro-ph.IM

TiAu TES 32$\times$32 pixel array: uniformity, thermal crosstalk and performance at different X-ray energies

Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 $μ$m$^2$ TiAu TESs, which have \textcolor{black}{a 2.3 $μ$m} thick Au absorber for X-ray photons. The pixels have a typical normal resistance $R_\mathrm{n}$ = 121 m$Ω$ and a critical temperature $T_\mathrm{c}\sim$ 90 mK. We performed extensive measurements on 60 pixels out of the array in order to show the uniformity of the array. We obtained an energy resolutions between 2.4 and 2.6 eV (FWHM) at 5.9 keV, measured in a single-pixel mode at AC bias frequencies ranging from 1 to 5 MHz, with a frequency domain multiplexing (FDM) readout system, which is developed at SRON/VTT. We also present the detector energy resolution at X-ray with different photon energies generated by a modulated external X-ray source from 1.45 keV up to 8.9 keV. Multiplexing readout across several pixels has also been performed to evaluate the impact of the thermal crosstalk to the instrument's energy resolution budget requirement. This value results in a derived requirement, for the first neighbour, that is less than 1$\times$10$^{-3}$ when considering the ratio between the amplitude of the crosstalk signal to an X-ray pulse (for example at 5.9 keV)

astro-ph.IM

Characterization of high aspect ratio TiAu TES X-ray microcalorimeters array using the X-IFU Frequency Domain Multiplexing readout

We are developing X-ray microcalorimeters as a backup option for the baseline detectors in the X-IFU instrument on board the ATHENA space mission led by ESA and to be launched in the early 2030s.5$\times$5 mixed arrays with TiAu transition-edge sensor (TES), which have different high aspect ratios and thus high resistances, have been designed and fabricated to meet the energy resolution requirement of the X-IFU instrument. Such arrays can also be used to optimise the performance of the Frequency Domain Multiplexing (FDM) readout and lead to the final steps for the fabrication of a large detector array. In this work we present the experimental results from tens of the devices with an aspect ratio (length-to-width) ranging from 1-to-1 up to 6-to-1, measured in a single-pixel mode with a FDM readout system developed at SRON/VTT. We observed a nominal energy resolution of about 2.5 eV at 5.9 keV at bias frequencies ranging from 1 to 5 MHz. These detectors are proving to be the best TES microcalorimeters ever reported in Europe, being able to meet not only the requirements of the X-IFU instrument, but also those of other future challenging X-ray space missions, fundamental physics experiments, plasma characterization and material analysis.

physics.ins-det

AC/DC characterization of a Ti/Au TES with Au/Bi absorber for X-ray detection

Transition-edge sensors (TESs) are used as very sensitive thermometers in microcalorimeters aimed at detection of different wavelengths. In particular, for soft X-ray astrophysics, science goals require very high resolution microcalorimeters which can be achieved with TESs coupled to suitable absorbers. For many applications there is also need for a high number of pixels which typically requires multiplexing in the readout stage. Frequency Domain Multiplexing (FDM) is a common scheme and is the baseline proposed for the ATHENA mission. FDM requires biasing the TES in AC at MHz frequencies. Recently there has been reported degradation in performances under AC with respect to DC bias. In order to assess the performances of TESs to be used with FDM, it is thus of great interest to compare the performances of the same device both under AC and DC bias. This requires two different measurement setups with different processes for making the characterization. We report in this work the preliminary results of a single pixel characterization performed on a TiAu TES under AC and afterwards under DC bias in different facilities. Extraction of dynamical parameters and noise performances are compared in both cases as a first stage for further AC/DC comparison of these devices.

physics.ins-det