SearcharxivSearch

arXiv subjects

M. Romé

Publications and source records attributed to M. Romé.

10 recordsLinked to original sources

Measured Properties of an Antihydrogen Beam

We report a factor of $100$ increase in the antihydrogen beam intensity downstream of ASACUSA's Cusp trap: $320$ atoms detected per $15$-minute run. The beam contains many Rydberg atoms, which we selectively ionize to determine their velocity and binding energy. The time of flight signal is modeled using a $1\mathrm{D}$ Maxwellian velocity distribution with a temperature of $1500\,\mathrm{K}$, which is close to the measured antiproton plasma temperature. A numerical simulation reproduces the observed distribution of binding energies and suggests that about $16\%$ of the atoms may be in the ground state.

physics.ins-det

A large-momentum-transfer matter-wave interferometer to measure the effect of gravity on positronium

This paper reports the study of a new interferometric configuration to measure the effect of gravity on positronium. A Mach-Zehnder matter-wave interferometer has been designed to operate with single-photon transitions and to transfer high momentum to a 200 eV positronium beam. The work shows the results and methods used to simulate the interferometer and estimate the operating parameters and the time needed to perform the experiment. It has been estimated that within less than one year, the acquisition time is sufficient to achieve a 10\% accuracy level in measuring positronium gravitational acceleration, even with a poorly collimated beam, which is significant for theoretical models describing matter-antimatter symmetry. These results pave the way for single photon transition large momentum transfer interferometry with fast atomic beams, which is particularly useful for studies with antimatter and unstable atoms.

physics.atom-ph

Upgrade of the positron system of the ASACUSA-Cusp experiment

The ASACUSA-Cusp collaboration has recently upgraded the positron system to improve the production of antihydrogen. Previously, the experiment suffered from contamination of the vacuum in the antihydrogen production trap due to the transfer of positrons from the high pressure region of a buffer gas trap. This contamination reduced the lifetime of antiprotons. By adding a new positron accumulator and therefore decreasing the number of transfer cycles, the contamination of the vacuum has been reduced. Further to this, a new rare gas moderator and buffer gas trap, previously used at the Aarhus University, were installed. Measurements from Aarhus suggested that the number of positrons could be increased by a factor of four in comparison to the old system used at CERN. This would mean a reduction of the time needed for accumulating a sufficient number of positrons (of the order of a few million) for an antihydrogen production cycle. Initial tests have shown that the new system yields a comparable number of positrons to the old system.

physics.atom-ph

Slow positron production and storage for the ASACUSA-Cusp experiment

The ASACUSA Cusp experiment requires the production of dense positron plasmas with a high repetition rate to produce a beam of antihydrogen. In this work, details of the positron production apparatus used for the first observation of the antihydrogen beam, and subsequent measurements are described in detail. This apparatus replaced the previous compact trap design resulting in an improvement in positron accumulation by a factor of ($52\pm3)$

physics.plasm-ph

SDR, EVC, and SDREVC: Limitations and Extensions

Methods for reducing the radius, temperature, and space charge of nonneutral plasma are usually reported for conditions which approximate an ideal Penning Malmberg trap. Here we show that (1) similar methods are still effective under surprisingly adverse circumstances: we perform SDR and SDREVC in a strong magnetic mirror field using only 3 out of 4 rotating wall petals. In addition, we demonstrate (2) an alternative to SDREVC, using e-kick instead of EVC and (3) an upper limit for how much plasma can be cooled to T < 20 K using EVC. This limit depends on the space charge, not on the number of particles or the plasma density.

physics.plasm-ph

Upgrade of ASACUSA's Antihydrogen Detector

The goal of the ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) CUSP experiment at CERN's Antiproton Decelerator is to measure the ground state hyperfine splitting of antihydrogen in order to test whether CPT invariance is broken. The ASACUSA hodoscope is a detector consisting of two layers of 32 plastic scintillator bars individually read out by two serially connected silicon photo multipliers (SiPMs) on each end. Two additional layers for position resolution along the beam axis were scintillator fibres, which will now be replaced by scintillating tiles placed onto the existing bars and also read out by SiPMs. If the antiproton of antihydrogen annihilates in the center of the hodoscope, particles (mostly pions) are produced and travel through the various layers of the detector and produce signals. The hodoscope was successfully used during the last data taking period at CERN. The necessary time resolution to discriminate between particles travelling through the detector from outside and particles produced in the center of the detector was achieved by the use of waveform digitisers and software constant fraction discrimination. The disadvantage of this readout scheme was the slow readout speed, which was improved by two orders of magnitude. This was done by omitting the digitisers and replacing them with TDCs reading out the digital time-over-threshold (ToT) signal using leading edge discrimination.

physics.ins-det

Cyclotron cooling to cryogenic temperature in a Penning-Malmberg trap with a large solid angle acceptance

Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, resulting in significantly reduced plasma temperature.

physics.plasm-ph

Minimizing plasma temperature for antimatter mixing experiments

The ASACUSA collaboration produces a beam of antihydrogen atoms by mixing pure positron and antiproton plasmas in a strong magnetic field with a double cusp geometry. The positrons cool via cyclotron radiation inside the cryogenic trap. Low positron temperature is essential for increasing the fraction of antihydrogen atoms which reach the ground state prior to exiting the trap. Many experimental groups observe that such plasmas reach equilibrium at a temperature well above the temperature of the surrounding electrodes. This problem is typically attributed to electronic noise and plasma expansion, which heat the plasma. The present work reports anomalous heating far beyond what can be attributed to those two sources. The heating seems to be a result of the axially open trap geometry, which couples the plasma to the external (300 K) environment via microwave radiation.

physics.plasm-ph

Light Ion Accelerating Line (L3IA): Test Experiment at ILIL-PW

The construction of a novel Laser driven Light Ions Acceleration Line(L3IA) is progressing rapidly towards the operation, following the recent upgrade of the ILIL-PW laser facility. The Line was designed following the pilot experimental activity carried out earlier at the same facility to define design parameters and to identify main components including target control and diagnostic equipment, also in combination with the numerical simulations for the optimization of laser and target parameters. A preliminary set of data was acquired following the successful commissioning of the laser system >100 TW upgrade. Data include output from a range of different ion detectors and optical diagnostics installed for qualification of the laser-target interaction. An overview of the results is given along with a description of the relevant upgraded laser facility and features.

physics.plasm-ph

Detection of low energy antimatter with emulsions

Emulsion detectors feature a very high position resolution and consequently represent an ideal device when particle detection is required at the micrometric scale. This is the case of quantum interferometry studies with antimatter, where micrometric fringes have to be measured. In this framework, we designed and realized a new emulsion based detector characterized by a gel enriched in terms of silver bromide crystal contents poured on a glass plate. We tested the sensitivity of such a detector to low energy positrons in the range 10-20 keV. The obtained results prove that nuclear emulsions are highly efficient at detecting positrons at these energies. This achievement paves the way to perform matter-wave interferometry with positrons using this technology.

hep-ex