SearcharxivSearch

arXiv subjects

M. Ronquest

Publications and source records attributed to M. Ronquest.

11 recordsLinked to original sources

A Measurement of the Branching Ratio of $\pi^0$ Dalitz Decay using $K_L \rightarrow \pi^0\pi^0\pi^0$ Decays

We present a measurement of $B(\pi^0 \rightarrow e^+e^- \gamma)/B(\pi^0 \rightarrow \gamma\gamma)$, the Dalitz branching ratio, using data taken in 1999 by the E832 KTeV experiment at Fermi National Accelerator Laboratory. We use neutral pions from fully reconstructed $K_L$ decays in flight; the measurement is based on about 60 thousand $K_L \rightarrow \pi^0\pi^0\pi^0 \rightarrow \gamma\gamma~\gamma\gamma~e^+e^-\gamma$ decays. We normalize to $K_L \rightarrow \pi^0\pi^0\pi^0 \rightarrow 6\gamma$ decays. We find $B(\pi^0 \rightarrow e^+e^- \gamma)/B(\pi^0 \rightarrow \gamma\gamma)$ $(m_{e^+e^-}$ > 15 MeV/$c^2)$ = $[3.920 \pm 0.016(stat) \pm 0.036 (syst)] \times 10^{-3}$. Using the Mikaelian and Smith prediction for the $e^+e^-$ mass spectrum, we correct the result to the full $e^+e^-$ mass range. The corrected result is $B(\pi^0 \rightarrow e^+e^- \gamma)/B(\pi^0 \rightarrow \gamma\gamma) = [1.1559 \pm 0.0047(stat) \pm 0.0106 (syst)]$%. This result is consistent with previous measurements and the uncertainty is a factor of three smaller than any previous measurement.

hep-ex

Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector

The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them. The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.

astro-ph.IM

Search for the Rare Decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-

The KTeV E799 experiment has conducted a search for the rare decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-, where the X0 is a possible new neutral boson that was reported by the HyperCP experiment with a mass of (214.3 pm 0.5) MeV/c^{2}. We find no evidence for either decay. We obtain upper limits of Br(KL->pi0pi0X0->pi0pi0mu+mu-) < 1.0 x 10^{-10} and Br(KL->pi0pi0mu+mu-) < 9.2 x 10^{-11} at the 90% confidence level. This result rules out the pseudoscalar X0 as an explanation of the HyperCP result under the scenario that the \bar{d}sX0 coupling is completely real.

hep-ex

Precise Measurements of Direct CP Violation, CPT Symmetry, and Other Parameters in the Neutral Kaon System

We present precise tests of CP and CPT symmetry based on the full dataset of K to pipi decays collected by the KTeV experiment at Fermi National Accelerator Laboratory during 1996, 1997, and 1999. This dataset contains 16 million K to 2pi0 and 69 million K to pi+pi- decays. We measure the direct CP violation parameter Re(epsilon'/epsilon) = (19.2 pm 2.1)x10-4. We find the KL-KS mass difference Deltam = (5270 pm 12)x10^6 hbar/s and the KS lifetime tauS = (89.62 pm 0.05)x10-12 s. We also measure several parameters that test CPT invariance. We find the difference between the phase of the indirect CP violation parameter, epsilon, and the superweak phase, phi_epsilon - phi_SW = (0.40 pm 0.56) degrees. We measure the difference of the relative phases between the CP violating and CP conserving decay amplitudes for K to pi+pi- (phi+-) and for K to 2pi0 (phi00), Delta phi = (0.30 pm 0.35) degrees. From these phase measurements, we place a limit on the mass difference between K0 and K0bar, DeltaM < 4.8 x 10-19 GeV/c^2 at 95% C.L. These results are consistent with those of other experiments, our own earlier measurements, and CPT symmetry.

hep-ex

Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1

The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV. In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be $<1.4\times 10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil acceptance of at least 90%, with 4% systematic uncertainty on the absolute energy scale. The discrimination measurement on surface was limited by nuclear recoils induced by cosmic-ray generated neutrons. This was improved by moving the detector to the SNOLAB underground laboratory, where the reduced background rate allowed the same measurement with only a double-coincidence tag. The combined data set contains $1.23\times10^8$ events. One of those, in the underground data set, is in the nuclear-recoil region of interest. Taking into account the expected background of 0.48 events coming from random pileup, the resulting upper limit on the electronic recoil contamination is $<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil acceptance of at least 90%, with 6% systematic uncertainty on the absolute energy scale. We developed a general mathematical framework to describe PSD parameter distributions and used it to build an analytical model of the distributions observed in DEAP-1. Using this model, we project a misidentification fraction of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for a detector with 8 PE/keVee light yield. This reduction enables a search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming negligible contribution from nuclear recoil backgrounds.

astro-ph.IM

Search for the Rare Decay K_{L}\toπ^{0}π^{0}γ

The KTeV E799 experiment has conducted a search for the rare decay $K_{L}\toπ^{0}π^{0}γ$ via the topology $K_{L}\toπ^{0}π^{0}_Dγ$ (where $π^0_D\toγe^+e^-$). Due to Bose statistics of the $π^0$ pair and the real nature of the photon, the $K_{L}\toπ^{0}π^{0}γ$ decay is restricted to proceed at lowest order by the CP conserving direct emission (DE) of an E2 electric quadrupole photon. The rate of this decay is interesting theoretically since chiral perturbation theory predicts that this process vanishes at level $O(p^4)$. Therefore, this mode probes chiral perturbation theory at $O(p^6)$. In this paper we report a determination of an upper limit of $2.43\times 10^{-7}$ (90% CL) for $K_{L}\toπ^{0}π^{0}γ$. This is approximately a factor of 20 lower than previous results.

hep-ex

Observation of the Decay Xi^0 --> Sigma^+ mu^- nu(bar)

The Xi^0 muon semi-leptonic decay has been observed for the first time with nine identified events using the KTeV beam line and detector at Fermilab. The decay is normalized to the Xi^0 beta decay mode and yields a value for the ratio of decay rates of $(1.8^{+0.7}_{-0.5}(stat.)\pm0.2(syst.))\times 10^{-2}$. This is in agreement with the SU(3) flavor symmetric quark model.

hep-ex

Final Results from the KTeV Experiment on the Decay KL -> pi0 gamma gamma

We report on a new measurement of the branching ratio B(KL->pi0 gamma gamma)using the KTeV detector. We reconstruct 1982 events with an estimated background of 608, that results in B(KL -> pi0 gamma gamma) = (1.29 +/- 0.03(stat) +/- 0.05(syst)) x 10**-6. We also measure the parameter, aV, which characterizes the strength of vector meson exchange terms in this decay. We find aV = -0.31 +/- 0.05(stat) +/- 0.07(syst). These results utilize the full KTeV data set collected from 1997 to 2000 and supersede earlier KTeV measurements of the branching ratio and aV.

hep-ex

Determination of the Parity of the Neutral Pion via the Four-Electron Decay

We present a new determination of the parity of the neutral pion via the double Dalitz decay pi^0 -> e+ e- e+ e-. Our sample, which consists of 30511 candidate decays, was collected from K_L -> pi0 pi0 pi0 decays in flight at the KTeV-E799 experiment at Fermi National Accelerator Laboratory. We confirm the negative pi^0 parity, and place a limit on scalar contributions to the pi^0 -> e+ e- e+ e- decay amplitude of less than 3.3% assuming CPT conservation. The pi^0 gamma* gamma* form factor is well described by a momentum-dependent model with a slope parameter fit to the final state phase space distribution. Additionally, we have measured the branching ratio of this mode to be B(pi^0 -> e+ e- e+ e-) = (3.26 +- 0.18) x 10^(-5).

hep-ex

Measurement of the Decay KL -> pi0 e+ e- gamma

We report on a new measurement of the branching ratio B(KL -> pi0 e+ e- gamma) using the KTeV detector. This analysis uses the full KTeV data set collected from 1997 to 2000. We reconstruct 139 events over a background of 14, which results in B(KL -> pi0 e+ e- gamma) = (1.62 +/- 0.14 (stat) +/- 0.09 (syst)) x 10^{-8}. This result supersedes the earlier KTeV measurement of this branching ratio.

hep-ex

Measurements of the Branching Fractions and Decay Distributions for KL->\pi\mu\nu\gamma and KL->\pi e\nu\gamma

We present measurements of R_Kl3rad = Gamma(KL->\pi\ell\nu\gamma; Egcm > 10 MeV)/Gamma(KL->\pi\ell\nu), where ell = mu or e, and Egcm is the photon energy in the kaon rest frame. These measurements are based on KL decays collected in 1997 by the KTeV (E832) experiment at Fermilab. With samples of 1385 KL->\pi\mu\nu\gamma and 14221 KL->\pi\e\nu\gamma candidates, we find R_Km3rad = (0.530 +- 0.019)% and R_Ke3rad = (4.942 +- 0.062)%. We also examine distributions of photon energy and lepton-photon angle.

hep-ex