SearcharxivSearch

arXiv subjects

M. S. Dixit

Publications and source records attributed to M. S. Dixit.

4 recordsLinked to original sources

Spatial resolution of a GEM readout TPC using the charge dispersion signal

A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100 microns with a manageable number of readout pads and channels of electronics, Micro Pattern Gas Detectors (MPGD) are being developed which could use pads comparable in width to the proportional-wire/cathode-pad TPC. We have built a prototype GEM readout TPC with 2 mm x 6 mm pads using the new concept of charge dispersion in MPGDs with a resistive anode. The dependence of transverse resolution on the drift distance has been measured for small angle tracks in cosmic ray tests without a magnetic field for Ar/CO2 (90:10). The GEM-TPC resolution with charge dispersion readout is significantly better than previous measurements carried out with conventional direct charge readout techniques.

physics.ins-det

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode pad TPC and Micro-Pattern Gas Detectors (MPGD) are being developed to meet the challenge. The standard MPGD readout techniques will, however, have difficulty in achieving the ILC-TPC resolution goal with the 2 mm x 6 mm pads as was initially envisioned. Proposals for smaller width pads will improve the resolution but will require a larger number of readout channels and increase the TPC detector cost and complexity. The new MPGD readout concept of charge dispersion has the potential to achieve the ILC-TPC resolution goal without resorting to narrower pads. This was recently demonstrated in cosmic ray tests of a small prototype TPC read out with MPGDs using the charge dispersion technique. Here we describe the simulation of the charge dispersion phenomena for the MPGD-TPC. The detailed simulation includes initial ionization clustering, electron drift, diffusion effects, the intrinsic detector pulse-shape and electronics effects. The simulation is in excellent agreement with the experimental data and can be used to optimize the MPGD charge dispersion readout for the TPC.

physics.ins-det

Resolution studies of cosmic-ray tracks in a TPC with GEM readout

A large volume TPC is a leading candidate for the central tracking detector at a future high energy linear collider. To improve the resolution a new readout based on micro-pattern gas detectors is being developed. Measurements of the spatial resolution of cosmic-ray tracks in a GEM TPC are presented. We find that the resolution suffers if the readout pads are too wide with respect to the charge distribution at the readout plane due to insufficient charge sharing. For narrow pads of 2 x 6 mm**2 we measure a resolution of 100 micometer at short drift distances in the absence of an axial magnetic field. The dependence of the spatial resolution as a function of drift distance allows the determination of the underlying electron statistics. Our results show that the present technique uses about half the statistical power available from the number of primary electrons. The track angle effect is observed as expected.

physics.ins-det

Position Sensing from Charge Dispersion in Micro-Pattern Gas Detectors with a Resistive Anode

Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number of electronics channels for certain potential micro-detector applications such as the Time Projection Chamber. We describe below a new technique to achieve good spatial resolution without increasing the electronics channel count in a modified micro-detector outfitted with a high surface resistivity anode readout structure. The concept and preliminary measurements of spatial resolution from charge dispersion in a modified GEM detector with a resistive anode are described below.

physics.ins-det