Searcharxiv⌕ Search

arXiv subjects

M. Sandri

Publications and source records attributed to M. Sandri.

34 records · Page 2Linked to original sources

The linearity response of the Planck-LFI flight model receivers

In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.

astro-ph.IM↗

LFI Radiometric Chain Assembly (RCA) data handling "Rachel"

This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221). Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiometers. In this paper, we describe Rachel, a software application which has been purposely developed and used during the RCA test campaign to carry out both near-realtime on-line data analysis and data storage (in FITS format) of the raw output from the radiometric chains.

astro-ph.IM↗

Level 1 on-ground telemetry handling in Planck LFI

The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekeeping data by sampling regularly the on-board sensors and registers. The housekeeping data provides information on the overall health status of the instrument and on the scientific data quality. The scientific and housekeeping data are collected on-board into telemetry packets compliant with the ESA Packet Telemetry standards. They represent the primary input to the first processing level of the LFI Data Processing Centre. In this work we show the software systems which build the LFI Level 1. A real-time assessment system, based on the ESA SCOS 2000 generic mission control system, has the main purpose of monitoring the housekeeping parameters of LFI and detect possible anomalies. A telemetry handler system processes the housekeeping and scientific telemetry of LFI, generating timelines for each acquisition chain and each housekeeping parameter. Such timelines represent the main input to the subsequent processing levels of the LFI DPC. A telemetry quick-look system allows the real-time visualization of the LFI scientific and housekeeping data, by also calculating quick statistical functions and fast Fourier transforms. The LFI Level 1 has been designed to support all the mission phases, from the instrument ground tests and calibration to the flight operations, and developed according to the ESA engineering standards.

astro-ph.IM↗

Off-line radiometric analysis of Planck/LFI data

The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.

astro-ph.IM↗

Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.

astro-ph.IM↗

Planck pre-launch status: Design and description of the Low Frequency Instrument

In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.

astro-ph.IM↗

Making Maps from Planck LFI 30GHz Data with Asymmetric Beams and Cooler Noise

The Planck satellite will observe the full sky at nine frequencies from 30 to 857 GHz. The goal of this paper is to examine the effects of four realistic instrument systematics in the 30 GHz frequency maps: non-axially-symmetric beams, sample integration, sorption cooler noise, and pointing errors. We simulated one year long observations of four 30 GHz detectors. The simulated timestreams contained CMB, foreground components (both galactic and extra-galactic), instrument noise (correlated and white), and the four instrument systematic effects. We made maps from the timelines and examined the magnitudes of the systematics effects in the maps and their angular power spectra. We also compared the maps of different mapmaking codes to see how they performed. We used five mapmaking codes (two destripers and three optimal codes). None of our mapmaking codes makes an attempt to deconvolve the beam from its output map. Therefore all our maps had similar smoothing due to beams and sample integration. Temperature to polarization cross-coupling due to beam mismatch causes a detectable bias in the TE spectrum of the CMB map. The effects of cooler noise and pointing errors did not appear to be major concerns for the 30 GHz channel. The only essential difference found so far between mapmaking codes that affects accuracy (in terms of residual RMS) is baseline length. All optimal codes give essentially indistinguishable results. A destriper gives the same result as the optimal codes when the baseline is set short enough. For longer baselines destripers require less computing resources but deliver a noisier map.

astro-ph↗

The Planck Low Frequency Instrument

Planck is the third generation of mm-wave instruments designed for space observations of the cosmic microwave background (CMB) anisotropies within the new Cosmic Vision 2020 ESA Science Program. Planck will map the whole sky with unprecedented sensitivity, angular resolution, and frequency coverage, and it likely leads us to the final comprehension of the CMB anisotropies. The Low Frequency Instrument (LFI), operating in the 30-70 GHz range, is one of the two instruments onboard Planck satellite, sharing the focal region of a 1.5 meter off-axis dual reflector telescope together with the High Frequency Instrument (HFI) operating at 100-857 GHz. We present LFI and discuss the major instrumental systematic effects that could degrade the measurements and the solutions adopted in the design and data analysis phase in order to adequately reduce and control them.

astro-ph↗

High Performances Corrugated Feed Horns for Space Applications at Millimetre Wavelengths

We report on the design, fabrication and testing of a set of high performance corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission. The electromagnetic designs include linear (100 GHz) and dual shaped (30 and 70 GHz) profiles. Fabrication has been achieved by direct machining at 30 GHz, and by electro-formation at higher frequencies. The measured performances on side lobes and return loss meet the stringent Planck requirements over the large (20%) instrument bandwidth. Moreover, the advantage in terms of main lobe shape and side lobes levels of the dual profiled designs has been demonstrated.

astro-ph↗

Trade-off between angular resolution and straylight contamination in CMB anisotropy experiments. I. Pattern simulations

The study of Cosmic Microwave Background (CMB) anisotropies represents one of the most powerful Cosmological tools. After the great success of the two NASA's satellite missions COBE and WMAP, Planck represents the third generation of mm-wave instruments designed for space observations of CMB anisotropies within the new Cosmic Vision 2020 ESA Science Programme. The Planck survey will cover the whole sky with unprecedented sensitivity, angular resolution and frequency coverage, using two instruments that share the focal region of a 1.5 m off-axis dual reflector telescope: the Low Frequency Instrument (LFI) and the High Frequency Instrument (HFI). Within the LFI optical interfaces optimisation activity, two concurrent demands have to be satisfied: the best angular resolution (which impacts the ability to reconstruct the anisotropy power spectrum of the CMB anisotropies at high multipoles) and the lowest level of straylight contamination (that may be one of the most critical sources of systematic effects). We present the results of the optical simulations aimed to establish the trade-off between angular resolution and straylight rejection, carried out for the 100 GHz channel of Planck Low Frequency Instrument. Antenna pattern of different models of dual profiled corrugated conical feed horns have been simulated using advanced simulation techniques, considering the whole spacecraft geometry in order to obtain truthful sidelobe predictions. Optical computation accuracy necessary to provide strong straylight evaluation in reasonable computational time is shown and the inadequacy of a Gaussian feed model in realistic far pattern predictions is demonstrated. This paper is based on LFI activities.

astro-ph↗

PLANCK/LFI: an Advanced Multi-beam High Performance mm-wave Optics for Space Applications

The Low Frequency Instrument (LFI) is one of the two instruments onboard the ESA PLANCK satellite foreseen to be launched in 2007. The LFI will image the Cosmic Microwave Background (CMB) anisotropies and the polarization in four different bands, with an unprecedented combination of sky coverage, calibration accuracy, control of systematic errors, and sensitivity. LFI is coupled to the PLANCK Telescope by an array of 23 high performance dual profiled corrugated feed horns. The dual reflector off axis-design of the 1.5 meter projected aperture telescope is the most advanced optical design ever conceived for accommodating large multi-beam and multi-frequency focal plane units. The location and the design of the feed horns, for both instruments, have been optimised in order to maintain good beam symmetry, even far from the optical axis, and an excellent straylight rejection. In this paper we describe the LFI instrument with emphasis on its optical performance and coupling with the PLANCK telescope.

astro-ph↗

Advanced simulation techniques for straylight prediction of high performance mm-wave reflecting telescope

The prediction of the antenna radiation pattern can be extremely complex for antenna system composed of several reflector surfaces. Typically, at mm-wavelengths, telescopes are composed of mirrors and shields, and an accurate prediction of the whole system response is therefore complicated. This is the case for the optical system of the ESA Planck mission. Planck represents the third generation of mm-wave instruments designed for space observations of CMB anisotropies over the whole sky, and has unprecedented sensitivity and angular resolution. The Low Frequency Instrument (LFI) is one of the two instruments onboard the satellite. LFI consists of an array of 46 cooled HEMT-based receivers coupled to the 1.5 meter off-axis dual reflector telescope by an array of 23 dual profiled corrugated feed horns working at four frequencies between 30 and 100 GHz. Owing to the small level of CMB anisotropies, the control of the systematic effects is mandatory, and this is assured by means of a dedicated instrument design and by an accurate knowledge of instrument characteristics. The telescope is a source of systematic errors both in the main beam region (aberrations) and in the sidelobes region (straylight contamination) and efficient and accurate radiation pattern simulations of the telescope-feed system are needed. We report on the simulations of the full pattern applied to the Planck/LFI-Telescope system. These simulations, based on advanced GTD methods, are used to evaluate the straylight rejection of the entire optical system, by applying a new approach for evaluating the sidelobes in a rigorous way, even at very low levels.

astro-ph↗

Planck Low Frequency Instrument: Beam Patterns

The Low Frequency Instrument on board the ESA Planck satellite is coupled to the Planck 1.5 meter off-axis dual reflector telescope by an array of 27 corrugated feed horns operating at 30, 44, 70, and 100 GHz. We briefly present here a detailed study of the optical interface devoted to optimize the angular resolution (10 arcmin at 100 GHz as a goal) and at the same time to minimize all the systematics coming from the sidelobes of the radiation pattern. Through optical simulations, we provide shapes, locations on the sky, angular resolutions, and polarization properties of each beam.

astro-ph↗

Trade-off between angular resolution and straylight contamination in CMB anisotropy experiments. II. Straylight evaluation

Satellite CMB anisotropy missions and new generation of balloon-borne and ground experiments, make use of complex multi-frequency instruments at the focus of a meter class telescope. Between 70 GHz and 300 GHz, where foreground contamination is minimum, it is extremely important to reach the best trade-off between the improvement of the angular resolution and the minimization of the straylight contamination mainly due to the Galactic emission. We focus here, as a working case, on the 30 and 100 GHz channels of the Planck Low Frequency Instrument (LFI). We evaluate the GSC introduced by the most relevant Galactic foreground components for a reference set of optical configurations. We show that it is possible to improve the angular resolution of 5-7% by keeping the overall GSC below the level of few microKelvin. A comparison between the level of straylight introduced by the different Galactic components for different beam regions is presented. Simple approximate relations giving the rms and peak-to-peak levels of the GSC are provided. We compare the results obtained at 100 GHz with those at 30 GHz, where GSC is more critical. Finally, we compare the results based on Galactic foreground templates derived from radio and IR surveys with those based on WMAP maps including CMB and extragalactic source fluctuations.

astro-ph↗

Sources Variability With Planck LFI

Planck LFI (Low Frequency Instrument) will produce a complete survey of the sky at millimeter wavelengths. Data stream analysis will provide the possibility to reveal unexpected millimeter sources and to study their flux evolution in time at different frequencies. We describe here the main implications and discuss data analysis methods. Planck sensitivities typical for this kind of detection are taken into account. We present also preliminary results of our simulation activity.

astro-ph↗

The Planck Telescope

In this paper we present an overview of the Telescope designed for ESA's mission dedicated to map the Cosmic Microwave Background Anisotropies and Polarization. Two instruments, LFI and HFI, operate in an overall frequency range between 25 and 900 GHz and share the focal region of the 1.5 meter optimized telescope. The optimization techniques adopted for the optical design and the telescope characteristic are reported and discussed.

astro-ph↗