SearcharxivSearch

arXiv subjects

M. Schenk

Publications and source records attributed to M. Schenk.

11 recordsLinked to original sources

Beam Measurements and Machine Learning at the CERN Large Hadron Collider

This paper presents a review of the recent Machine Learning activities carried out on beam measurements performed at the CERN Large Hadron Collider. This paper has been accepted for publication in IEEE Instrumentation and Measurement Magazine and in the published version no abstract is provided.

physics.acc-ph

Machine learning for beam dynamics studies at the CERN Large Hadron Collider

Machine learning entails a broad range of techniques that have been widely used in Science and Engineering since decades. High-energy physics has also profited from the power of these tools for advanced analysis of colliders data. It is only up until recently that Machine Learning has started to be applied successfully in the domain of Accelerator Physics, which is testified by intense efforts deployed in this domain by several laboratories worldwide. This is also the case of CERN, where recently focused efforts have been devoted to the application of Machine Learning techniques to beam dynamics studies at the Large Hadron Collider (LHC). This implies a wide spectrum of applications from beam measurements and machine performance optimisation to analysis of numerical data from tracking simulations of non-linear beam dynamics. In this paper, the LHC-related applications that are currently pursued are presented and discussed in detail, paying also attention to future developments.

physics.acc-ph

Report on the ECFA Early-Career Researchers Debate on the 2020 European Strategy Update for Particle Physics

A group of Early-Career Researchers (ECRs) has been given a mandate from the European Committee for Future Accelerators (ECFA) to debate the topics of the current European Strategy Update (ESU) for Particle Physics and to summarise the outcome in a brief document [1]. A full-day debate with 180 delegates was held at CERN, followed by a survey collecting quantitative input. During the debate, the ECRs discussed future colliders in terms of the physics prospects, their implications for accelerator and detector technology as well as computing and software. The discussion was organised into several topic areas. From these areas two common themes were particularly highlighted by the ECRs: sociological and human aspects; and issues of the environmental impact and sustainability of our research.

hep-ex

Shape Control for Experimental Continuation

An experimental method has been developed to locate unstable equilibria of nonlinear structures quasi-statically. The technique involves loading a structure by application of either a force or a displacement at a main actuation point, while simultaneously controlling the overall shape using additional probe points. The method is applied to a shallow arch, and unstable segments of its equilibrium path are identified experimentally for the first time. Shape control is a fundamental building block for the experimental---as opposed to numerical---continuation of nonlinear structures, which will significantly expand our ability to measure their mechanical response.

physics.app-ph

Measurement of the drift field in the ARGONTUBE LAr TPC with 266~nm pulsed laser beams

ARGONTUBE is a liquid argon time projection chamber (LAr TPC) with a drift field generated in-situ by a Greinacher voltage multiplier circuit. We present results on the measurement of the drift-field distribution inside ARGONTUBE using straight ionization tracks generated by an intense UV laser beam. Our analysis is based on a simplified model of the charging of a multi-stage Greinacher circuit to describe the voltages on the field cage rings.

physics.ins-det

Performance of cryogenic charge readout electronics with the ARGONTUBE LAr TPC

ARGONTUBE is a liquid argon time projection chamber (TPC) with an electron drift length of up to 5 m equipped with cryogenic charge-sensitive preamplifiers. In this work, we present results on its performance including a comparison of the new cryogenic charge-sensitive preamplifiers with the previously used room-temperature-operated charge preamplifiers.

physics.ins-det

A steerable UV laser system for the calibration of liquid argon time projection chambers

A number of liquid argon time projection chambers (LAr TPC's) are being build or are proposed for neutrino experiments on long- and short baseline beams. For these detectors a distortion in the drift field due to geometrical or physics reasons can affect the reconstruction of the events. Depending on the TPC geometry and electric drift field intensity this distortion could be of the same magnitude as the drift field itself. Recently, we presented a method to calibrate the drift field and correct for these possible distortions. While straight cosmic ray muon tracks could be used for calibration, multiple coulomb scattering and momentum uncertainties allow only a limited resolution. A UV laser instead can create straight ionization tracks in liquid argon, and allows one to map the drift field along different paths in the TPC inner volume. Here we present a UV laser feed-through design with a steerable UV mirror immersed in liquid argon that can point the laser beam at many locations through the TPC. The straight ionization paths are sensitive to drift field distortions, a fit of these distortion to the linear optical path allows to extract the drift field, by using these laser tracks along the whole TPC volume one can obtain a 3D drift field map. The UV laser feed-through assembly is a prototype of the system that will be used for the MicroBooNE experiment at the Fermi National Accelerator Laboratory (FNAL).

physics.ins-det

Experimental study of electric breakdowns in liquid argon at centimeter scale

In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are observed for a length of 300 mm starting from a voltage of 55 kV. These results contribute to set reference for the breakdown-free design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).

physics.ins-det

Development of a camera casing suited for cryogenic and vacuum applications

We report on the design, construction, and operation of a PID temperature controlled and vacuum tight camera casing. The camera casing contains a commercial digital camera and a lighting system. The design of the camera casing and its components are discussed in detail. Pictures taken by this cryo-camera while immersed in argon vapour and liquid nitrogen are presented. The cryo-camera can provide a live view inside cryogenic set-ups and allows to record video.

physics.ins-det

Electrostatic extraction of cold molecules from a cryogenic reservoir

We present a method which delivers a continuous, high-density beam of slow and internally cold polar molecules. In our source, warm molecules are first cooled by collisions with a cryogenic helium buffer gas. Cold molecules are then extracted by means of an electrostatic quadrupole guide. For ND$_3$ the source produces fluxes up to $(7 \pm ^{7}_{4}) \times 10^{10}$ molecules/s with peak densities up to $(1.0 \pm ^{1.0}_{0.6}) \times 10^9$ molecules/cm$^3$. For H$_2$CO the population of rovibrational states is monitored by depletion spectroscopy, resulting in single-state populations up to $(82 \pm 10)%$.

physics.chem-ph

Internal-state thermometry by depletion spectroscopy in a cold guided beam of formaldehyde

We present measurements of the internal state distribution of electrostatically guided formaldehyde. Upon excitation with continuous tunable ultraviolet laser light the molecules dissociate, leading to a decrease in the molecular flux. The population of individual guided states is measured by addressing transitions originating from them. The measured populations of selected states show good agreement with theoretical calculations for different temperatures of the molecule source. The purity of the guided beam as deduced from the entropy of the guided sample using a source temperature of 150K corresponds to that of a thermal ensemble with a temperature of about 30 K.

physics.chem-ph