SearcharxivSearch

arXiv subjects

M. Schumann

Publications and source records attributed to M. Schumann.

At least 19 recordsLinked to original sources

Performance of a first multi-cell WOM-based liquid scintillator detector as prototype for the SHiP Surrounding Background Tagger

The Search for Hidden Particles (SHiP) Experiment was approved by CERN in 2024. Feebly-interacting particles that are produced in a proton Beam Dump Facility (BDF) will decay in the 50m-long Decay Volume of the experiment, which needs to be enveloped by a hermetic veto detector: The Surrounding Background Tagger (SBT). Its technology relies on liquid scintillator, composed of linear alkylbenzene and 2,5-diphenyloxazole, as active detector material and Wavelength-shifting Optical Module (WOM) tubes collecting the primary scintillation photons. The liquid scintillator volume is segmented in large cells of typically 120cm x 80cm x 20cm that are equipped with two WOMs each. Here, we report on the performance of a full-scale 2x2-cell prototype detector which was exposed to 5GeV muons at the CERN PS T9 test beam facility to study the detector response and its time and spatial resolution for minimum ionising particles crossing multiple detector cells.

physics.ins-det

Development & Characterization of Electrodes for large-scale Xenon Time Projection Chambers

Dual-phase liquid xenon time projection chambers are the core detector elements of many experiments that conduct searches for Dark Matter and rare events, as well as in neutrino and high-energy physics. As part of this detector technology, high-voltage electrodes are instrumental for the generation of observable signals and their physical interpretation. Thus, electrode design and manufacturing has to fulfill stringent requirements, and their production is associated with significant engineering challenges. In this work we describe the successful development of electrodes on the 1.5 m-scale, from their design and simulation to subsequent assembly and high-voltage testing in a gaseous argon environment. The produced electrodes were recently installed as an anode and a cathode during an upgrade to the XENONnT experiment.

physics.ins-det

Search for solar axions produced through the axion-electron coupling $g_{ae}$ using a new GridPix detector at CAST

We present a search for solar axions produced through the axion-electron coupling $(g_{ae})$ using data from a novel 7-GridPix detector installed at the CERN Axion Solar Telescope (CAST). The detector, featuring ultra-thin silicon nitride windows and multiple veto systems, collected approximately 160 hours of solar tracking data between 2017-2018. Using machine learning techniques and the veto systems, we achieved a background rate of $1.06\times 10^{-5}\,\text{keV}^{-1}\text{cm}^{-2}\text{s}^{-1}$ at a signal efficiency of about $80\,\%$ in the $0.2$-$8\,\text{keV}$ range. Analysis of the data yielded no significant excess above background, allowing us to set a new upper limit on the product of the axion-electron and axion-photon couplings of $g_{ae}\cdot g_{a\gamma} < 7.35\times 10^{-23}\,\text{GeV}^{-1}$ at $95\,\%$ confidence level. This result improves upon the previous best helioscope limit and demonstrates the potential of GridPix technology for rare event searches. Additionally, we derived a limit on the axion-photon coupling of $g_{a\gamma} < 9.0\times 10^{-11}\,\text{GeV}^{-1}$ at $95\,\%$ CL, which, while not surpassing CAST's best limit, provides complementary constraints on axion models.

hep-ex

Performance of Prototypes with Different Reflector Materials for the SHiP Liquid Scintillator Surrounding Background Tagger

The baseline technology for the Surrounding Background Tagger of the recently approved SHiP experiment relies on liquid scintillator composed of linear alkylbenzene and 2,5-diphenyloxazole as active detector material. The primary scintillation photons are collected by Wavelength-shifting Optical Modules, and the secondary photons are guided by total reflection to an array of 40 silicon photomultipliers. Here we present a direct comparison of the performance of three detector prototype cells constructed from different alternative materials known to provide good chemical compatibility with the liquid scintillator: Aluminium and stainless steel. To increase the internal reflectivity, one of the two aluminium prototypes was polished on the inside, while the inner walls of the stainless steel cell were clad with sheets of polytetrafluoroethylene. Using 5 GeV muons from the CERN PS T10 beamline, we studied detected light yield and time resolution attained by the three prototypes. For both the polished AlMg4.5 cell and the PTFE-clad stainless steel prototype, the achieved detected light yield and time resolution meet the requirements of the SHiP Surrounding Background Tagger. Concerning another crucial parameter, the uniformity of the detector response across the detector cell, the polished AlMg4.5 cell shows the best performance among the tested prototypes. These results will significantly affect the final design of the SHiP Surrounding Background Tagger.

physics.ins-det

A new upper limit on the axion-photon coupling with an extended CAST run with a Xe-based Micromegas detector

Hypothetical axions provide a compelling explanation for dark matter and could be emitted from the hot solar interior. The CERN Axion Solar Telescope (CAST) has been searching for solar axions via their back conversion to X-ray photons in a 9-T 10-m long magnet directed towards the Sun. We report on an extended run with the IAXO (International Axion Observatory) pathfinder detector, doubling the previous exposure time. The detector was operated with a xenon-based gas mixture for part of the new run, providing technical insights for future detector configurations in IAXO. No counts are detected in the 95% signal-encircling region during the new run, while 0.75 are expected. The new data improve the axion-photon coupling limit to 5.8$\times 10^{-11}\,$GeV$^{-1}$ at 95% C.L. (for $m_a \lesssim 0.02$ eV), the most restrictive experimental limit to date.

hep-ex

Performance of a First Full-Size WOM-Based Liquid Scintillator Detector Cell as Prototype for the SHiP Surrounding Background Tagger

As a prototype detector for the SHiP Surrounding Background Tagger (SBT), we constructed a cell (120 cm x 80 cm x 25 cm) made from corten steel that is filled with liquid scintillator (LS) composed of linear alkylbenzene (LAB) and 2,5-diphenyloxazole (PPO). The detector is equipped with two Wavelength-shifting Optical Modules (WOMs) for light collection of the primary scintillation photons. Each WOM consists of an acrylic tube that is dip-coated with a wavelength-shifting layer on its surface. Via internal total reflection, the secondary photons emitted by the molecules of the wavelength shifter are guided to a ring-shaped array of 40 silicon photomultipliers (SiPMs) coupled to the WOM for light detection. The granularity of these SiPM arrays provides an innovative method to gain spatial information on the particle crossing point. Several improvements in the detector design significantly increased the light yield with respect to earlier proof-of-principle detectors. We report on the performance of this prototype detector during an exposure to high-energy positrons at the DESY II test beam facility by measuring the collected integrated yield and the signal time-of-arrival in each of the SiPM arrays. The resulting detection efficiency and reconstructed energy deposition of the incident positrons are presented, as well as the spatial and time resolution of the detector. These results are then compared to Monte Carlo simulations.

physics.ins-det

A High-Sensitivity Radon Emanation Detector System for Future Low-Background Experiments

Radioactive radon atoms originating from the long-lived primordial $^{238}\mathrm{U}$ and $^{232}\mathrm{Th}$ decay chains are constantly emanated from the surfaces of most materials. The radon atoms and their radioactive daughter isotopes can significantly contribute to the background of low-background experiments. The $^{222}\mathrm{Rn}$ progeny $^{214}\mathrm{Pb}$, for example, dominates the background of current liquid xenon-based direct dark matter detectors. We report on a new detector system to directly quantify the $^{222}\mathrm{Rn}$ surface emanation rate of materials. Using cryogenic physisorption traps, emanated radon atoms are transferred from an independent emanation vessel and concentrated within the dedicated detection vessel. The charged daughter isotopes are collected electrostatically on a silicon PIN photodiode to spectrometrically measure the alpha decays of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$. The overall detection efficiency is $\sim 36\,\%$ for both polonium channels. The radon emanation activity of the emanation vessel was measured to be $(0.16\pm 0.03)\,\mathrm{mBq}$, resulting in a detection sensitivity of $\sim 0.06\,\mathrm{mBq}$ at $90\,\%\,\mathrm{C.L.}$.

physics.ins-det

Search for Dark Matter Axions with CAST-CAPP

The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 $\mu$eV to 22.47 $\mu$eV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to $g_{a{\gamma}{\gamma}} = 8 \times {10^{-14}}$ $GeV^{-1}$ at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades.

hep-ex

GPU-based optical simulation of the DARWIN detector

Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

physics.ins-det

First measurement of the surface tension of a liquid scintillator based on Linear Alkylbenzene (HYBLENE 113)

We measured the surface tension of linear alkylbenzene (LAB) HYBLENE 113 mixed with Diphenyloxazole (PPO) as well as of pure LAB HYBLENE 113 as part of material studies for the liquid-scintillator based surround background tagger (SBT) in the proposed SHiP experiment. The measurement was performed using the iron wire method and the surface tension for linear alkyl benzene HYBLENE 113 plus PPO was found to be $(30.0\pm0.6)$ mN/m $22.0\pm 0.5$ {\deg}C and for pure HYBLENE 113, $(29.2\pm 0.6)$ mN/m at $21.0\pm 0.5$ {\deg}C.

physics.ins-det

First results of the CAST-RADES haloscope search for axions at 34.67 $\mu$eV

We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67$\mu$eV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of g$_{a\gamma}\gtrsim 4\times10^{-13} \text{GeV}^{-1}$ over a mass range of 34.6738 $\mu$eV < $m_a$ < 34.6771 $\mu$eV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 $\mu$eV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities.

hep-ex

Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.

physics.ins-det

Testing claims of the GW170817 binary neutron star inspiral affecting $β$-decay rates

On August 17, 2017, the first gravitational wave signal from a binary neutron star inspiral (GW170817) was detected by Advanced LIGO and Advanced VIRGO. Here we present radioactive $β$-decay rates of three independent sources $^{44}$Ti, $^{60}$Co and $^{137}$Cs, monitored during the same period by a precision experiment designed to investigate the decay of long-lived radioactive sources. We do not find any significant correlations between decay rates in a 5\,h time interval following the GW170817 observation. This contradicts a previous claim published in this journal of an observed 2.5$σ$ Pearson Correlation between fluctuations in the number of observed decays from two $β$-decaying isotopes ($^{32}$Si and $^{36}$Cl) in the same time interval. By correcting for the choice of an arbitrary time interval, we find no evidence of a correlation above 1.5$σ$ confidence. In addition, we argue that such analyses on correlations in arbitrary time intervals should always correct for the so-called Look-Elsewhere effect by quoting the global significance.

nucl-ex

First Results on the Search for Chameleons with the KWISP Detector at CAST

We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of solar chameleons. The displacements are detected by a Michelson interferometer with a homodyne readout scheme. The sensor benefits from the focusing action of the ABRIXAS X-ray telescope installed at CAST, which increases the chameleon flux on the membrane. A mechanical chopper placed between the telescope output and the detector modulates the incoming chameleon stream. We present the results of the solar chameleon measurements taken at CAST in July 2017, setting an upper bound on the force acting on the membrane of $80$~pN at 95\% confidence level. The detector is sensitive for direct coupling to matter $10^4 \leqβ_m \leq 10^8$, where the coupling to photons is locally bound to $β_γ\leq 10^{11}$.

hep-ex

No correlation between Solar flares and the decay rate of several $β$-decaying isotopes

We report on finding no correlation between the two strongest observed Solar flares in September 2017 and the decay rates of $^{60}$Co, $^{44}$Ti and $^{137}$Cs sources, which are continuously measured by two independent NaI(Tl) detector setups. We test for variations in the number of observed counts with respect to the number of expected counts over multiple periods with timescales varying from 1 to 109 hours around the Solar flare. No excess or deficit exceeds the 2$σ$ global significance. We set a conservative lower limit on the decay rate deviation over an 84-hour period around the two correlated Solar flares in September 2017 to $0.044\%$ with 2$σ$ confidence. A fractional change of $~0.1\%$ in the decay rate of $^{54}$Mn over a period of 84 hours was claimed with 7$σ$ significance during multiple Solar flares in December 2006. We exclude such an effect at 4.7$σ$ significance.

nucl-ex

Dark Matter Search Results from a One Tonne$\times$Year Exposure of XENON1T

We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\ -3}\textrm{ (sys)}\pm3\textrm{ (stat)})$ events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant excess over background is found and a profile likelihood analysis parameterized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses above 6 GeV/c${}^2$, with a minimum of $4.1\times10^{-47}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence level.

astro-ph.CO

A Precision Experiment to Investigate Long-Lived Radioactive Decays

Radioactivity is understood to be described by a Poisson process, yet some measurements of nuclear decays appear to exhibit unexpected variations. Generally, the isotopes reporting these variations have long half lives, which are plagued by large measurement uncertainties. In addition to these inherent problems, there are some reports of time-dependent decay rates and even claims of exotic neutrino-induced variations. We present a dedicated experiment for the stable long-term measurement of gamma emissions resulting from $β$ decays, which will provide high-quality data and allow for the identification of potential systematic influences. Radioactive isotopes are monitored redundantly by thirty-two 76 mm $\times$ 76 mm NaI(Tl) detectors in four separate temperature-controlled setups across three continents. In each setup, the monitoring of environmental and operational conditions facilitates correlation studies. The deadtime-free performance of the data acquisition system is monitored by LED pulsers. Digitized photomultiplier waveforms of all events are recorded individually, enabling a study of time-dependent effects spanning microseconds to years, using both time-binned and unbinned analyses. We characterize the experiment's stability and show that the relevant systematics are accounted for, enabling precise measurements of effects at levels well below $\mathcal{O}(10^{-4})$.

nucl-ex

Intrinsic backgrounds from Rn and Kr in the XENON100 experiment

In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and krypton ($^{85}$Kr). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main three science runs of the experiment over a period of $\sim$ 4 years, from January 2010 to January 2014. We compare our results to external measurements of radon emanation and krypton concentrations where we find good agreement. We report an observed reduction in concentrations of radon daughters that we attribute to the plating-out of charged ions on the negatively biased cathode.

astro-ph.IM