SearcharxivSearch

arXiv subjects

M. Shao

Publications and source records attributed to M. Shao.

At least 19 recordsLinked to original sources

Sub-Pixel Calibration of CMOS Sensors for Precision Astrometry

Many sources of systematic error are important to centroid the position of a star below the level of $10^{-4}$ of the FWHM of the stellar image. One of the more important sources of centroiding error is the imperfect position of the pixels in a focal plane array. In this paper, we discuss the calibration of pixel position of multiple commercial CMOS detectors. Focal plane arrays are semiconductor devices fabricated with 10's nanometer precision. However, the effective location of a pixel can be biased if there's a QE gradient across the pixel. We typically see pixel position variations of 1--3\% of a pixel in most CMOS imagers. This paper describes how we measure the position of each pixel below the $10^{-3}$ pixel level. We also describe how this information might be used in a least square fitting of an airy spot to obtain a higher accuracy position of the centroid of the PSF.

astro-ph.IM

A high rate and high timing photoelectric detector prototype with RPC structure

To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the single photoelectron performance of different mixed gases was tested with an ultraviolet laser. The detector uses a low resistivity ($\sim1.4\cdot 10^{10} \Omega\cdot cm$) float glass so that its rate capability is significantly higher than that of ordinary float glass($10^{12}\sim10^{14} \Omega\cdot cm$), the laser test results show that in MRPC gas($R134a/iC_{4}H_{10}/SF_{6}(85/10/5)$), the single photoelectron time resolution is best to reach 20.3 ps at a gas gain of $7\cdot 10^{6}$. Increasing the proportion of $iC_{4}H_{10}$ can effectively reduce the probability of photon feedback, without changing the time resolution and maximum gain. In addition to being applied to high-precision time measurement scenarios (eg:T0, TOF), the detector can also quantitatively test the single photoelectron performance of different gases and will be used to find eco-friendly MRPC gases.

physics.ins-det

A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

physics.ins-det

Characterisation of resistive MPGDs with 2D readout

Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.

physics.ins-det

Design and performance testing of a T0 detector for the CSR External-target Experiment

The Cooling Storage Ring (CSR) External-target Experiment (CEE) at the Heavy Ion Research Facility in Lanzhou (HIRFL), China, is the first multi-purpose nuclear physics experimental device to operate in the Giga electron-volt (GeV) energy range. The primary goals of the CEE are to study the bulk properties of dense matter and to understand the quantum chromo-dynamic (QCD) phase diagram by measuring the charged particles produced in heavy-ion collisions in the target region with a large acceptance. The CEE is a spectrometer that focuses on charged final-state particle measurements running on the HIRFL-CSR. The time-of-flight (TOF) system is critical for identifying charged particles in the GeV energy region. In the CEE spectrometer, the TOF system consists of three parts: T0, internal TOF, and external TOF, which are used for the final-state particle identification. The T0 detector provides a high-precision start time for the TOF system by measuring the crossing time of the heavy ion beam. This study details the design, performance simulation, and performance testing of the T0 detector. The simulation results and heavy-ion beam test show that the T0 detector prototype has an excellent time resolution, which is better than 30 ps, and fulfills the requirements of the CEE.

physics.ins-det

R & D of prototype iTOF-MRPC at CEE

The cooling storage ring (CSR) external-target experiment (CEE) is a spectrometer running at the Heavy Ion Research Facility (HIRFL) at Lanzhou. The CEE is the first large-scale nuclear physics experimental device by China to operate in the fixed-target mode with an energy of 1 GeV. The purpose of the CEE is to study the properties of dense nuclear matter. CEE uses a multi-gap resistive plate chamber (MRPC) as its internal time-of-flight (iTOF) detector for the identification of final-state particles. An iTOF-MRPC prototype with 24 gaps was designed to meet the requirements of CEE, and the readout electronics of the prototype use the FPGA-based time digitization technology. Using cosmic ray tests, the time resolution of the iTOF prototype was found to be approximately 30 ps. In order to further understand how to improve the time resolution of MRPC, ANSYS HFSS was used to simulate the signal transmission process in MRPC. The main factors affecting the timing performance of the MRPC and, accordingly, the optimization scheme are presented.

physics.ins-det

Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.

physics.ins-det

ESA Voyage 2050 white paper -- Faint objects in motion: the new frontier of high precision astrometry

Sky survey telescopes and powerful targeted telescopes play complementary roles in astronomy. In order to investigate the nature and characteristics of the motions of very faint objects, a flexibly-pointed instrument capable of high astrometric accuracy is an ideal complement to current astrometric surveys and a unique tool for precision astrophysics. Such a space-based mission will push the frontier of precision astrometry from evidence of earth-massed habitable worlds around the nearest starts, and also into distant Milky way objects up to the Local Group of galaxies. As we enter the era of the James Webb Space Telescope and the new ground-based, adaptive-optics-enabled giant telescopes, by obtaining these high precision measurements on key objects that Gaia could not reach, a mission that focuses on high precision astrometry science can consolidate our theoretical understanding of the local universe, enable extrapolation of physical processes to remote redshifts, and derive a much more consistent picture of cosmological evolution and the likely fate of our cosmos. Already several missions have been proposed to address the science case of faint objects in motion using high precision astrometry ESA missions: NEAT for M3, micro-NEAT for S1 mission, and Theia for M4 and M5. Additional new mission configurations adapted with technological innovations could be envisioned to pursue accurate measurements of these extremely small motions. The goal of this white paper is to address the fundamental science questions that are at stake when we focus on the motions of faint sky objects and to briefly review quickly instrumentation and mission profiles.

astro-ph.IM

Astro2020 Science White Paper: Science at the edges: internal kinematics of globular clusters' external fields

The outer regions of globular clusters can enable us to answer many fundamental questions concerning issues ranging from the formation and evolution of clusters and their multiple stellar populations to the study of stars near and beyond the hydrogen-burning limit and to the dynamics of the Milky Way. The outskirts of globular clusters are still uncharted territories observationally. A very efficient way to explore them is through high-precision proper motions of low-mass stars over a large field of view. The Wide Field InfraRed Survey Telescope (WFIRST) combines all these characteristics in a single telescope, making it the best observational tool to uncover the wealth of information contained in the clusters' outermost regions.

astro-ph.GA

A detector interferometric calibration experiment for high precision astrometry

Context: Exoplanet science has made staggering progress in the last two decades, due to the relentless exploration of new detection methods and refinement of existing ones. Yet astrometry offers a unique and untapped potential of discovery of habitable-zone low-mass planets around all the solar-like stars of the solar neighborhood. To fulfill this goal, astrometry must be paired with high precision calibration of the detector. Aims: We present a way to calibrate a detector for high accuracy astrometry. An experimental testbed combining an astrometric simulator and an interferometric calibration system is used to validate both the hardware needed for the calibration and the signal processing methods. The objective is an accuracy of 5e-6 pixel on the location of a Nyquist sampled polychromatic point spread function. Methods: The interferometric calibration system produced modulated Young fringes on the detector. The Young fringes were parametrized as products of time and space dependent functions, based on various pixel parameters. The minimization of func- tion parameters was done iteratively, until convergence was obtained, revealing the pixel information needed for the calibration of astrometric measurements. Results: The calibration system yielded the pixel positions to an accuracy estimated at 4e-4 pixel. After including the pixel position information, an astrometric accuracy of 6e-5 pixel was obtained, for a PSF motion over more than five pixels. In the static mode (small jitter motion of less than 1e-3 pixel), a photon noise limited precision of 3e-5 pixel was reached.

astro-ph.IM

The latest results from DICE (Detector Interferometric Calibration Experiment)

Theia is an astrometric mission proposed to ESA in 2014 for which one of the scientific objectives is detecting Earth-like exoplanets in the habitable zone of nearby solar-type stars. This objective requires the capability to measure stellar centroids at the precision of 1e-5 pixel. Current state-of-the-art methods for centroid estimation have reached a precision of about 3e-5 pixel at two times Nyquist sampling, this was shown at the JPL by the VESTA experiment. A metrology system was used to calibrate intra and inter pixel quantum efficiency variations in order to correct pixelation errors. The Theia consortium is operating a testbed in vacuum in order to achieve 1e-5 pixel precision for the centroid estimation. The goal is to provide a proof of concept for the precision requirement of the Theia spacecraft. The testbed consists of two main sub-systems. The first one produces pseudo stars: a blackbody source is fed into a large core fiber and lights-up a pinhole mask in the object plane, which is imaged by a mirror on the CCD. The second sub-system is the metrology, it projects young fringes on the CCD. The fringes are created by two single mode fibers facing the CCD and fixed on the mirror. In this paper we present the latest experiments conducted and the results obtained after a series of upgrades on the testbed was completed. The calibration system yielded the pixel positions to an accuracy estimated at 4e-4 pixel. After including the pixel position information, an astrometric accuracy of 6e-5 pixel was obtained, for a PSF motion over more than 5 pixels. In the static mode (small jitter motion of less than 1e-3 pixel), a photon noise limited precision of 3e-5 pixel was reached.

astro-ph.IM

Cosmic Ray Test of Mini-drift Thick Gas Electron Multiplier Chamber for Transition Radiation Detector

A thick gas electron multiplier (THGEM) chamber with an effective readout area of 10$\times$10 cm$^{2}$ and a 11.3 mm ionization gap has been tested along with two regular gas electron multiplier (GEM) chambers in a cosmic ray test system. The thick ionization gap makes the THGEM chamber a mini-drift chamber. This kind mini-drift THGEM chamber is proposed as part of a transition radiation detector (TRD) for identifying electrons at an Electron Ion Collider (EIC) experiment. Through this cosmic ray test, an efficiency larger than 94$\%$ and a spatial resolution $\sim$220 $μ$m are achieved for the THGEM chamber at -3.65 kV. Thanks to its outstanding spatial resolution and thick ionization gap, the THGEM chamber shows excellent track reconstruction capability. The gain uniformity and stability of the THGEM chamber are also presented.

physics.ins-det

Reconnaissance of the HR 8799 Exosolar System II: Astrometry and Orbital Motion

We present an analysis of the orbital motion of the four sub-stellar objects orbiting HR8799. Our study relies on the published astrometric history of this system augmented with an epoch obtained with the Project 1640 coronagraph + Integral Field Spectrograph (IFS) installed at the Palomar Hale telescope. We first focus on the intricacies associated with astrometric estimation using the combination of an Extreme Adaptive Optics system (PALM-3000), a coronagraph and an IFS. We introduce two new algorithms. The first one retrieves the stellar focal plane position when the star is occulted by a coronagraphic stop. The second one yields precise astrometric and spectro-photometric estimates of faint point sources even when they are initially buried in the speckle noise. The second part of our paper is devoted to studying orbital motion in this system. In order to complement the orbital architectures discussed in the literature, we determine an ensemble of likely Keplerian orbits for HR8799bcde, using a Bayesian analysis with maximally vague priors regarding the overall configuration of the system. While the astrometric history is currently too scarce to formally rule out coplanarity, HR8799d appears to be misaligned with respect to the most likely planes of HR8799bce orbits. This misalignment is sufficient to question the strictly coplanar assumption made by various authors when identifying a Laplace resonance as a potential architecture. Finally, we establish a high likelihood that HR8799de have dynamical masses below 13 M_Jup using a loose dynamical survival argument based on geometric close encounters. We illustrate how future dynamical analyses will further constrain dynamical masses in the entire system.

astro-ph.SR

Metrology calibration and very high accuracy centroiding with the NEAT testbed

NEAT is an astrometric mission proposed to ESA with the objectives of detecting Earth-like exoplanets in the habitable zone of nearby solar-type stars. NEAT requires the capability to measure stellar centroids at the precision of 5e-6 pixel. Current state-of-the-art methods for centroid estimation have reached a precision of about 2e-5 pixel at two times Nyquist sampling, this was shown at the JPL by the VESTA experiment. A metrology system was used to calibrate intra and inter pixel quantum efficiency variations in order to correct pixelation errors. The European part of the NEAT consortium is building a testbed in vacuum in order to achieve 5e-6 pixel precision for the centroid estimation. The goal is to provide a proof of concept for the precision requirement of the NEAT spacecraft. The testbed consists of two main sub-systems. The first one produces pseudo stars: a blackbody source is fed into a large core fiber and lights-up a pinhole mask in the object plane, which is imaged by a mirror on the CCD. The second sub-system is the metrology, it projects young fringes on the CCD. The fringes are created by two single mode fibers facing the CCD and fixed on the mirror. In this paper we present the experiments conducted and the results obtained since July 2013 when we had the first light on both the metrology and pseudo stars. We explain the data reduction procedures we used.

astro-ph.IM

Test of High Time Resolution MRPC with Different Readout Modes

In order to further enhance the particle identification capability of the Beijing Spectrometer (BESIII), it is proposed to upgrade the current end-cap time-of-flight (eTOF) detector with multi-gap resistive plate chamber (MRPC). The prototypes, together with the front end electronics (FEE) and time digitizer (TDIG) module have been tested at the E3 line of Beijing Electron Positron Collider (BEPCII) to study the difference between the single and double-end readout MRPC designs. The time resolutions (sigma) of the single-end readout MRPC are 47/53 ps obtained by 600 MeV/c proton/pion beam, while that of the double-end readout MRPC is 40 ps (proton beam). The efficiencies of three MRPC modules tested by both proton and pion beam are better than 98%. For the double-end readout MRPC, no incident position dependence is observed.

physics.ins-det

First experimental results of very high accuracy centroiding measurements for the neat astrometric mission

NEAT is an astrometric mission proposed to ESA with the objectives of detecting Earth-like exoplanets in the habitable zone of nearby solar-type stars. NEAT requires the capability to measure stellar centroids at the precision of 5e-6 pixel. Current state-of-the-art methods for centroid estimation have reached a precision of about 2e-5 pixel at two times Nyquist sampling, this was shown at the JPL by the VESTA experiment. A metrology system was used to calibrate intra and inter pixel quantum efficiency variations in order to correct pixelation errors. The European part of the NEAT consortium is building a testbed in vacuum in order to achieve 5e-6 pixel precision for the centroid estimation. The goal is to provide a proof of concept for the precision requirement of the NEAT spacecraft. In this paper we present the metrology and the pseudo stellar sources sub-systems, we present a performance model and an error budget of the experiment and we report the present status of the demonstration. Finally we also present our first results: the experiment had its first light in July 2013 and a first set of data was taken in air. The analysis of this first set of data showed that we can already measure the pixel positions with an accuracy of about 1e-4 pixel.

astro-ph.IM

Reconnaissance of the HR 8799 Exosolar System I: Near IR Spectroscopy

We obtained spectra, in the wavelength range λ= 995 - 1769 nm, of all four known planets orbiting the star HR 8799. Using the suite of instrumentation known as Project 1640 on the Palomar 5-m Hale Telescope, we acquired data at two epochs. This allowed for multiple imaging detections of the companions and multiple extractions of low-resolution (R ~ 35) spectra. Data reduction employed two different methods of speckle suppression and spectrum extraction, both yielding results that agree. The spectra do not directly correspond to those of any known objects, although similarities with L and T-dwarfs are present, as well as some characteristics similar to planets such as Saturn. We tentatively identify the presence of CH_4 along with NH_3 and/or C_2H_2, and possibly CO_2 or HCN in varying amounts in each component of the system. Other studies suggested red colors for these faint companions, and our data confirm those observations. Cloudy models, based on previous photometric observations, may provide the best explanation for the new data presented here. Notable in our data is that these presumably co-eval objects of similar luminosity have significantly different spectra; the diversity of planets may be greater than previously thought. The techniques and methods employed in this paper represent a new capability to observe and rapidly characterize exoplanetary systems in a routine manner over a broad range of planet masses and separations. These are the first simultaneous spectroscopic observations of multiple planets in a planetary system other than our own.

astro-ph.EP

An experimental testbed for NEAT to demonstrate micro-pixel accuracy

NEAT is an astrometric mission proposed to ESA with the objectives of detecting Earth-like exoplanets in the habitable zone of nearby solar-type stars. In NEAT, one fundamental aspect is the capability to measure stellar centroids at the precision of 5e-6 pixel. Current state-of-the-art methods for centroid estimation have reached a precision of about 4e-5 pixel at Nyquist sampling. Simulations showed that a precision of 2 micro-pixels can be reached, if intra and inter pixel quantum efficiency variations are calibrated and corrected for by a metrology system. The European part of the NEAT consortium is designing and building a testbed in vacuum in order to achieve 5e-6 pixel precision for the centroid estimation. The goal is to provide a proof of concept for the precision requirement of the NEAT spacecraft. In this paper we give the basic relations and trade-offs that come into play for the design of a centroid testbed and its metrology system. We detail the different conditions necessary to reach the targeted precision, present the characteristics of our current design and describe the present status of the demonstration.

astro-ph.IM