SearcharxivSearch

arXiv subjects

M. Shimomura

Publications and source records attributed to M. Shimomura.

8 recordsLinked to original sources

Beam test results of the Intermediate Silicon Tracker for sPHENIX

The Intermediate Silicon Tracker (INTT), a two-layer barrel silicon strip tracker, is a key component of the tracking system for sPHENIX at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The INTT is designed to enable the association of reconstructed tracks with individual RHIC bunch crossings. To evaluate the performance of preproduction INTT ladders and the readout chain, a beam test was conducted at the Research Center for Accelerator and Radioisotope Science, Tohoku University, Japan. This paper presents the performance of the INTT evaluated through studies of the signal-to-noise ratio, residual distribution, spatial resolution, hit-detection efficiency, and multiple track reconstruction.

physics.ins-det

The Ladder and Readout Cables of Intermediate Silicon Strip Detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78~$μm$ pitch and 320~$μm$ thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8$\times$2 and 5$\times$2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

physics.ins-det

Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter

We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS and SPS beam lines with hadron (electron) beams up to energies of 350 (300) GeV. Regarding FoCal-E, we report a comprehensive analysis of its response to minimum ionizing particles across all pad layers. The longitudinal shower profile of electromagnetic showers is measured with a layer-wise segmentation of 1$X_0$. As a projection to the performance of the final detector in electromagnetic showers, we demonstrate linearity in the full energy range, and show that the energy resolution fulfills the requirements for the physics needs. Additionally, the performance to separate two-showers events was studied by quantifying the transverse shower width. Regarding FoCal-H, we report a detailed analysis of the response to hadron beams between 60 and 350 GeV. The results are compared to simulations obtained with a Geant4 model of the test beam setup, which in particular for FoCal-E are in good agreement with the data. The energy resolution of FoCal-E was found to be lower than 3% at energies larger than 100 GeV. The response of FoCal-H to hadron beams was found to be linear, albeit with a significant intercept that is about factor 2 larger than in simulations. Its resolution, which is non-Gaussian and generally larger than in simulations, was quantified using the FWHM, and decreases from about 16% at 100 GeV to about 11% at 350 GeV. The discrepancy to simulations, which is particularly evident at low hadron energies, needs to be further investigated.

physics.ins-det

A Large-Scale Pad-Sensor Based Prototype of the Silicon Tungsten Electromagnetic Calorimeter for the Forward Direction in ALICE at LHC

We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'', consists of 20 layers of silicon pad sensors and tungsten alloy plates with printed circuit boards and readout electronics. The constructed detector was tested at the test beam facility of the Super Proton Synchrotron (SPS) at CERN. We obtain an energy resolution of about 4.3% for electron beams at both 150 and 250 GeV/$c$, which is consistent with realistic detector response simulations. Longitudinal profiles of electromagnetic shower were also measured and found to agree with the simulations. The same prototype detector was installed in the ALICE experimental area about 7.5m away from the interaction point. It was used to measure inclusive electromagnetic cluster energy distributions and neutral-pion candidate invariant mass distributions for pseudo-rapidity of $η$=3.7-4.5 in proton-proton collisions at $\sqrt{s}$ = 13 TeV at LHC. The measured distributions in different $η$ regions are similar to those obtained from PYTHIA simulations.

physics.ins-det

Fully gapped pairing state in spin-triplet superconductor UTe$_2$

Spin-triplet superconductors provide an ideal platform for realizing topological superconductivity with emergent Majorana quasiparticles. The promising candidate is the recently discovered superconductor UTe$ _2$, but the symmetry of the superconducting order parameter remains highly controversial. Here we determine the superconducting gap structure by the thermal conductivity of ultra-clean UTe$ _2$ single crystals. We find that the $a$ axis thermal conductivity divided by temperature $κ/T$ in zero-temperature limit is vanishingly small for both magnetic fields $\mathbf{H}||a$ and $\mathbf{H}||c$ axes up to $H/H_{c2}\sim 0.2$, demonstrating the absence of any types of nodes around $a$ axis contrary to the previous belief. The present results, combined with the reduction of the NMR Knight shift in the superconducting state, indicate that the superconducting order parameter belongs to the isotropic $A_u$ representation with a fully gapped pairing state, analogous to the B phase of superfluid $ ^3$He. These findings reveal that UTe$ _2$ is likely to be a long-sought three-dimensional (3D) strong topological superconductor characterized by a 3D winding number, hosting helical Majorana surface states on any crystal plane.

cond-mat.supr-con

Evidence for the first-order topological phase transition in a Kitaev spin liquid candidate $α$-RuCl$ _3$

The Kitaev quantum spin liquid (QSL) on the two-dimensional honeycomb lattice epitomizes an entangled topological state, where the spins fractionalize into Majorana fermions. This state has aroused tremendous interest because it harbors non-Abelian anyon excitations. The half-integer quantized thermal Hall (HIQTH) conductance observed in $α$-RuCl$_3$ is a key signature of these excitations. However, the fate of this topologically nontrivial state at intense fields remains largely elusive. Here, we report the thermal conductivity $κ$ and specific heat $C$ of $α$-RuCl$_3$ with in-plane magnetic fields $H$. For the field direction perpendicular to the Ru-Ru bond, where the HIQTH effect is observed, we find a discontinuous jump in $κ(H)$ and a peak anomaly in $C(H)$ at $μ_0H^*\approx11$\,T, evidencing a weak first-order phase transition. Remarkably, the HIQTH effect vanishes close to $H^*$. Furthermore, we find that the spin-fractionalization feature is retained well above $H^\ast$. These imply the emergence of the phase transition that separates two QSL phases with distinct topological properties.

cond-mat.str-el

Design and Performance of a Silicon Tungsten Calorimeter Prototype Module and the Associated Readout

We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance of a custom ASIC designed for fast, lower-power, high-granularity applications.

physics.ins-det

A Reaction Plane Detector for PHENIX at RHIC

A plastic scintillator paddle detector with embedded fiber light guides and photomultiplier tube readout, referred to as the Reaction Plane Detector (RXNP), was designed and installed in the PHENIX experiment prior to the 2007 run of the Relativistic Heavy Ion Collider (RHIC). The RXNP's design is optimized to accurately measure the reaction plane (RP) angle of heavy-ion collisions, where, for mid-central $\sqrt{s_{NN}}$ = 200 GeV Au+Au collisions, it achieved a $2^{nd}$ harmonic RP resolution of $\sim$0.75, which is a factor of $\sim$2 greater than PHENIX's previous capabilities. This improvement was accomplished by locating the RXNP in the central region of the PHENIX experiment, where, due to its large coverage in pseudorapidity ($1.0<|η|<2.8$) and $ϕ$ (2$π$), it is exposed to the high particle multiplicities needed for an accurate RP measurement. To enhance the observed signal, a 2-cm Pb converter is located between the nominal collision region and the scintillator paddles, allowing neutral particles produced in the heavy-ion collisions to contribute to the signal through conversion electrons. This paper discusses the design, operation and performance of the RXNP during the 2007 RHIC run.

nucl-ex