SearcharxivSearch

arXiv subjects

M. Shirchenko

Publications and source records attributed to M. Shirchenko.

At least 73 records · Page 4Linked to original sources

The Majorana Demonstrator Radioassay Program

The MAJORANA collaboration is constructing the MAJORANA DEMONSTATOR at the Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD. The apparatus will use Ge detectors, enriched in isotope \nuc{76}{Ge}, to demonstrate the feasibility of a large-scale Ge detector experiment to search for neutrinoless double beta decay. The long half-life of this postulated process requires that the apparatus be extremely low in radioactive isotopes whose decays may produce backgrounds to the search. The radioassay program conducted by the collaboration to ensure that the materials comprising the apparatus are sufficiently pure is described. The resulting measurements of the radioactive-isotope contamination for a number of materials studied for use in the detector are reported.

physics.ins-det

High voltage testing for the MAJORANA Demonstrator

The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge effects during the MAJORANA Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

physics.ins-det

Flux Modulations seen by the Muon Veto of the GERDA Experiment

The GERDA experiment at LNGS of INFN is equipped with an active muon veto. The main part of the system is a water Cherenkov veto with 66~PMTs in the water tank surrounding the GERDA cryostat. The muon flux recorded by this veto shows a seasonal modulation. Two effects have been identified which are caused by secondary muons from the CNGS neutrino beam (2.2 %) and a temperature modulation of the atmosphere (1.4 %). A mean cosmic muon rate of $I^0_μ = (3.477 \pm 0.002_{\textrm{stat}} \pm 0.067_{\textrm{sys}}) \times 10^{-4}$/(s$\cdot$m$^2$) was found in good agreement with other experiments at LNGS at a depth of 3500~meter water equivalent.

physics.ins-det

The Performance of the Muon Veto of the GERDA Experiment

Low background experiments need a suppression of cosmogenically induced events. The GERDA experiment located at LNGS is searching for the neutrinless double beta decay of $^{76}$Ge. It is equipped with an active muon veto the main part of which is a water Cherenkov veto with 66 PMTs in the watertank surrounding the GERDA cryostat. With this system 806 live days have been recorded, 491 days were combined muon-germanium data. A muon detection efficiency of $\varepsilon_{μd}=(99.935\pm0.015)$ \% was found in a Monte Carlo simulation for the muons depositing energy in the germanium detectors. By examining coincident muon-germanium events a rejection efficiency of $\varepsilon_{μr}=(99.2_{-0.4}^{+0.3})$ \% was found. Without veto condition the muons by themselves would cause a background index of $\textrm{BI}_μ=(3.16 \pm 0.85)\times10^{-3}$ cts/(keV$\cdot$kg$\cdot$yr) at $Q_{ββ}$.

physics.ins-det

Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam

While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.

physics.ins-det

Status of the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44-kg (29 kg 76Ge and 15 kg natGe) to search for neutrinoless double beta decay in Ge-76. The next generation of tonne-scale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First, the prototype module was assembled; it has been continuously taking data from July 2014 to June 2015. Second, Module 1 with more than half of the total enriched detectors and some natural detectors has been assembled and it is being commissioned. Finally, the assembly of Module 2, which will complete MAJORANA DEMONSTRATOR, is already in progress.

physics.ins-det

Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration will seek neutrinoless double beta decay (0nbb) in 76Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of such an experiment, the MAJORANA DEMONSTRATOR, a 40 kg HPGe detector array, is being constructed with a background goal of <3 counts/ROI-tonne-year, which is expected to scale down to <1 count/ROI-tonne-year for a tonne-scale experiment. The signal readout electronics, which must be placed in close proximity to the detectors, present a challenge toward reaching this background goal. This talk will discuss the materials and design used to construct signal readout electronics with low enough backgrounds for the MAJORANA DEMONSTRATOR.

physics.ins-det

Analysis techniques for background rejection at the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40-kg modular HPGe detector array to search for neutrinoless double beta decay in 76Ge. In view of the next generation of tonne-scale Ge-based 0nbb-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The background rejection techniques to be applied to the data include cuts based on data reduction, pulse shape analysis, event coincidences, and time correlations. The Point Contact design of the DEMONSTRATOR 0s germanium detectors allows for significant reduction of gamma background.

physics.ins-det

$2νββ$ decay of $^{76}$Ge into excited states with GERDA Phase I

Two neutrino double beta decay of $^{76}$Ge to excited states of $^{76}$Se has been studied using data from Phase I of the GERDA experiment. An array composed of up to 14 germanium detectors including detectors that have been isotopically enriched in $^{76}$Ge was deployed in liquid argon. The analysis of various possible transitions to excited final states is based on coincidence events between pairs of detectors where a de-excitation $γ$ ray is detected in one detector and the two electrons in the other. No signal has been observed and an event counting profile likelihood analysis has been used to determine Frequentist 90\,\% C.L. bounds for three transitions: ${0^+_{\rm g.s.}-2^+_1}$: $T^{2ν}_{1/2}>$1.6$\cdot10^{23}$ yr, ${0^+_{\rm g.s.}-0^+_1}$: $T^{2ν}_{1/2}>$3.7$\cdot10^{23}$ yr and ${0^+_{\rm g.s.}-2^+_2}$: $T^{2ν}_{1/2}>$2.3$\cdot10^{23}$ yr. These bounds are more than two orders of magnitude larger than those reported previously. Bayesian 90\,\% credibility bounds were extracted and used to exclude several models for the ${0^+_{\rm g.s.}-0^+_1}$ transition.

hep-ex

The Majorana Demonstrator: A Search for Neutrinoless Double-beta Decay of 76Ge

Neutrinoless double-beta decay is a hypothesized process where in some even-even nuclei it might be possible for two neutrons to simultaneously decay into two protons and two electrons without emitting neutrinos. This is possible only if neutrinos are Majorana particles, i.e. fermions that are their own antiparticles. Neutrinos being Majorana particles would explicitly violate lepton number conservation, and might play a role in the matter-antimatter asymmetry in the universe. The observation of neutrinoless double-beta decay would also provide complementary information related to neutrino masses. The Majorana Collaboration is constructing the Majorana Demonstrator, a 40-kg modular germanium detector array, to search for the Neutrinoless double-beta decay of 76Ge and to demonstrate a background rate at or below 3 counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value for 76Ge Neutrinoless double-beta decay. In this paper, we discuss the physics of neutrinoless double beta decay and then focus on the Majorana Demonstrator, including its design and approach to achieve ultra-low backgrounds and the status of the experiment.

nucl-ex

Improvement of the Energy Resolution via an Optimized Digital Signal Processing in GERDA Phase I

An optimized digital shaping filter has been developed for the GERDA experiment which searches for neutrinoless double beta decay in 76Ge. The GERDA Phase I energy calibration data have been reprocessed and an average improvement of 0.3 keV in energy resolution (FWHM) at the 76Ge Q value for 0νββdecay is obtained. This is possible thanks to the enhanced low-frequency noise rejection of this Zero Area Cusp (ZAC) signal shaping fillter.

physics.ins-det

Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR

The MAJORANA DEMONSTRATOR is a planned 40 kg array of Germanium detectors intended to demonstrate the feasibility of constructing a tonne-scale experiment that will seek neutrinoless double beta decay ($0νββ$) in $^{76}\mathrm{Ge}$. Such an experiment would require backgrounds of less than 1 count/tonne-year in the 4 keV region of interest around the 2039 keV Q-value of the $ββ$ decay. Designing low-noise electronics, which must be placed in close proximity to the detectors, presents a challenge to reaching this background target. This paper will discuss the MAJORANA collaboration's solutions to some of these challenges.

physics.ins-det

The Majorana Parts Tracking Database

The Majorana Demonstrator is an ultra-low background physics experiment searching for the neutrinoless double beta decay of $^{76}$Ge. The Majorana Parts Tracking Database is used to record the history of components used in the construction of the Demonstrator. The tracking implementation takes a novel approach based on the schema-free database technology CouchDB. Transportation, storage, and processes undergone by parts such as machining or cleaning are linked to part records. Tracking parts provides a great logistics benefit and an important quality assurance reference during construction. In addition, the location history of parts provides an estimate of their exposure to cosmic radiation. A web application for data entry and a radiation exposure calculator have been developed as tools for achieving the extreme radio-purity required for this rare decay search.

physics.ins-det

MAJORANA Collaboration's Experience with Germanium Detectors

The goal of the \textsc{Majorana} \textsc{Demonstrator} project is to search for 0$νββ$ decay in $^{76}\mathrm{Ge}$. Of all candidate isotopes for 0$νββ$, $^{76}\mathrm{Ge}$ has some of the most favorable characteristics. Germanium detectors are a well established technology, and in searches for 0$νββ$, the high purity germanium crystal acts simultaneously as source and detector. Furthermore, p-type germanium detectors provide excellent energy resolution and a specially designed point contact geometry allows for sensitive pulse shape discrimination. This paper will summarize the experiences the \textsc{Majorana} collaboration made with enriched germanium detectors manufactured by ORTEC$^{\circledR}$. The process from production, to characterization and integration in \textsc{Majorana} mounting structure will be described. A summary of the performance of all enriched germanium detectors will be given.

physics.ins-det

Results on $ββ$ decay with emission of two neutrinos or Majorons in $^{76}$Ge from GERDA Phase I

A search for neutrinoless $ββ$ decay processes accompanied with Majoron emission has been performed using data collected during Phase I of the GERmanium Detector Array (GERDA) experiment at the Laboratori Nazionali del Gran Sasso of INFN (Italy). Processes with spectral indices n = 1, 2, 3, 7 were searched for. No signals were found and lower limits of the order of 10$^{23}$ yr on their half-lives were derived, yielding substantially improved results compared to previous experiments with $^{76}$Ge. A new result for the half-life of the neutrino-accompanied $ββ$ decay of $^{76}$Ge with significantly reduced uncertainties is also given, resulting in $T^{2ν}_{1/2} = (1.926 \pm 0.095)\cdot10^{21}$ yr.

nucl-ex

Status of the MAJORANA Demonstrator

The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 40-kg modular high purity Ge detector array to search for neutrinoless double-beta decay in Ge. In view of the next generation of tonne-scale Ge-based neutrinoless double-beta decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The current status of the Demonstrator is discussed, as are plans for its completion.

physics.ins-det

Production, characterization and operation of $^{76}$Ge enriched BEGe detectors in GERDA

The GERmanium Detector Array (GERDA) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of $^{76}$Ge. Germanium detectors made of material with an enriched $^{76}$Ge fraction act simultaneously as sources and detectors for this decay. During Phase I of the experiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new $^{76}$Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in GERDA during Phase I. The present paper reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the $^{76}$Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. The detector performance fulfills the requirements needed for the physics goals of GERDA Phase~II.

physics.ins-det

A Dark Matter Search with MALBEK

The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimballton Underground Research Facility. With its sub-keV energy threshold, this detector is sensitive to potential non-Standard Model physics, including interactions with WIMPs. We discuss the backgrounds present in the WIMP region of interest and explore the impact of slow surface event contamination when searching for a WIMP signal.

nucl-ex