SearcharxivSearch

arXiv subjects

M. Silarski

Publications and source records attributed to M. Silarski.

At least 19 recordsLinked to original sources

High-precision measurement of the kaonic hydrogen 1s level shift and width with SIDDHARTA-2

Kaonic atoms provide a unique experimental probe of strong interaction in the low-energy regime. In particular, the strong-interaction-induced shift ($\varepsilon_{1\text{s}}$) and width ($\Gamma_{1\text{s}}$) of kaonic hydrogen directly constrain the low-energy antikaon-nucleon ($\bar{K}N$) interaction at threshold and the theoretical description of the $\Lambda$(1405) resonance. We report a new high-precision measurement of kaonic hydrogen X-ray transitions performed by the SIDDHARTA-2 experiment at the DA$\Phi$NE collider (INFN-LNF), based on an integrated luminosity of 237 pb$^{-1}$. The extracted values, $\varepsilon_{1\text{s}}\,=\,-303.0\,\pm\,17.0\,(stat.)\,\pm\,2.5\,(syst.)$ eV and $\Gamma_{1\text{s}}\,=\,607\,\pm\,62\,(stat.)\,\pm\,6\,(syst.)$ eV, represent the most precise determination to date, improving the precision by approximately a factor-of-two with respect to the previous SIDDHARTA measurement. These results significantly tighten the experimental constraints on theoretical description of the low-energy $\bar{K}N$ interaction.

nucl-ex

Bound-state QED test above the Schwinger limit with kaonic fluorine

Kaonic atoms, formed when a negatively charged kaon replaces an electron in an atomic orbit, provide access to bound-state quantum electrodynamics (BSQED) in electromagnetic fields far stronger than in ordinary atoms. Here, we report an experimental test of BSQED in a regime where the mean Coulomb field exceeds the Schwinger limit. Using high-precision x-ray spectroscopy of kaonic fluorine with the SIDDHARTA-2 experiment at DA$Φ$NE, corresponding to an integrated luminosity of 22.4 pb$^{-1}$, we observe transitions involving the 4f and 3d levels, probing field-to-Schwinger-limit ratios of 1.11 and 3.70, respectively. The measured transition energies agree with state-of-the-art Dirac-Fock calculations. In particular, the 5g-4f transition showing a residual of 5.8 $\pm$ 4.7 (stat.) $\pm$ 5.5 (syst.) eV and a $\sim$ 9$σ$ sensitivity to QED contributions. These results provide a direct test of BSQED in the strong-field regime of QED above the Schwinger limit, opening a new avenue for precision studies in extreme electromagnetic fields.

physics.atom-ph

Precision Test of Bound-State QED at Intermediate-Z with Kaonic Neon

We report Dirac-Fock calculations of transition energies for kaonic neon (KNe). For the most intense line, the 7-6 transition, the calculated energy is 9450.28 eV, which includes a bound-state QED (BSQED) contribution of 12.66 eV. This is in excellent agreement with the recent SIDDHARTHA-2 measurement at DA$Φ$NE of 9450.23 $\pm$ 0.37 (stat.) $\pm$ 1.50 (syst.) eV. With the QED shift far exceeding experimental uncertainty, these results establish kaonic atoms as powerful platforms for precision tests of BSQED in intermediate-Z systems.

physics.atom-ph

Measurement of $η\toπ^{0}γγ$ branching fraction with the KLOE detector

We present a measurement of the radiative decay $η\toπ^0γγ$ using 82 million $η$ mesons produced in $e^+e^-\toϕ\toηγ$ process at the Frascati $ϕ$-factory DA$Φ$NE. From the data analysis $1246\pm133$ signal events are observed. By normalising the signal to the well-known $η\to3π^0$ decay the branching fraction ${\cal B}(η\toπ^0γγ)$ is measured to be $(0.98\pm 0.11_\text{stat}\pm 0.14_\text{syst})\times10^{-4}$. This result agrees with a preliminary KLOE measurement, but is twice smaller than the present world average. Results for $dΓ(η\toπ^0γγ)/dM^2(γγ)$ are also presented and compared with latest theory predictions.

hep-ex

TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.

physics.med-ph

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blue-emitting plastic scintillators with low attenuation of visible light were tested, namely: polyvinyl toluene-based BC-408, EJ-200, RP-408, and polystyrene-based Epic, SP32 and UPS-923A. For determination of the best type of plastic scintillator for totalbody Jagiellonian positron emission tomograph (TB-J-PET) construction, emission and transmission spectra, and technical attenuation length (TAL) of blue light-emitting by the scintillators were measured and compared. The TAL values were determined with the use of UV lamp as excitation source, and photodiode as light detector. Emission spectra of investigated scintillators have maxima in the range from 420 nm to 429 nm. The BC-408 and EJ-200 have the highest transmittance values of about 90% at the maximum emission wavelength measured through a 6 mm thick scintillator strip and the highest technical attenuation length reaching about 2000 mm, allowing assembly of long detection modules for time-of-flight (TOF) J-PET scanners. Influence of the 6 mm x 6 mm, 12 mm x 6 mm, 24 mm x 6 mm cross-sections of the 1000 mm long EJ-200 plastic scintillator on the TAL and signal intensity was measured. The highest TAL value was determined for samples with 24 mm x 6 mm cross-section.

physics.ins-det

Kaonic lead feasibility measurement at DAΦNE to solve the charged kaon mass discrepancy

An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons impinging on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.

physics.ins-det

SIDDHARTA-2 apparatus for kaonic atoms research on the DA$Φ$NE collider

SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms provides an exceptional tool to comprehend the strong interactions in the non-perturbative regime involving strangeness. The experiment is installed at the DA$Φ$NE electron-positron collider, of the INFN National Laboratory of Frascati (INFN-LNF) in Italy, aiming to perform the first-ever measurement of the 2p$\rightarrow$1s X-ray transitions in kaonic deuterium, a crucial step towards determining the isospin-dependent antikaon-nucleon scattering lengths. Based on the experience gained with the previous SIDDHARTA experiment, which performed the most precise measurement of the kaonic hydrogen 2p$\rightarrow$1s X-ray transitions, the present apparatus has been upgraded with innovative Silicon Drift Detectors (SDDs), distributed around a cryogenic gaseous target placed in a vacuum chamber at a short distance above the interaction region of the collider. We present a comprehensive description of the SIDDHARTA-2 setup including the optimization of its various components during the commissioning phase of the collider.

physics.ins-det

CdZnTe detectors tested at the DAΦNE collider for future kaonic atoms measurements

The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$Φ$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam delivered by the at-rest decay of the $ϕ$ meson. CdZnTe devices are ideal for detecting transitions toward both the upper and lower levels of intermediate-mass kaonic atoms, like kaonic carbon and aluminium, which have an important impact on the strangeness sector of nuclear physics. We present the results obtained in a set of preliminary tests conducted on DA$Φ$NE, in view of measurements foreseen in 2024, with the twofold aim to tune the timing window required to reject the extremely high electromagnetic background, and to quantify the readout electronics saturation effect due to the high rate, when placed close to the Interaction Region (IR). In the first test we used commercial devices and electronics, while for the second one both were customized at the IMEM-CNR of Parma and the University of Palermo. The results confirmed the possibility of finding and matching a proper timing window where to identify the signal events and proved better performances, in terms of energy resolution, of the custom system. In both cases, strong saturation effects were confirmed, accounting for a loss of almost 90\% of the events, which will be overcome by a dedicated shielding structure foreseen for the final experimental setup.

physics.ins-det

Measurements of high-n transitions in intermediate mass kaonic atoms by SIDDHARTA-2 at DA$\mathrmΦ$NE

The SIDDHARTA-2 experiment installed at the DA$\mathrmΦ$NE collider of INFN-LNF performed, for the first time, measurements of high-n transitions in intermediate mass kaonic atoms during the data taking campaigns of 2021 and 2022. Kaonic carbon, oxygen, nitrogen and aluminium transitions, which occur in the setup materials, were measured by using the kaons stopped in the gaseous helium target cell with aluminium frames and Kapton walls, and are reported in this paper. These new kaonic atoms measurements add valuable input to the kaonic atoms transitions data base, which is used as a reference for theories and models of the low-energy strong interaction between antikaon and nuclei. Moreover, these results pave the way for future dedicated kaonic atoms measurements through the whole periodic table and to a new era for the antikaon-nuclei studies at low energy.

nucl-ex

New opportunities for kaonic atoms measurements from CdZnTe detectors

We present the tests performed by the SIDDHARTA-2 collaboration at the DAΦNE collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy-mass kaonic atoms. The CdZnTe detector was installed for the first time in an accelerator environment to perform tests on the background rejection capabilities, which were achieved by exploiting the SIDDHARTA-2 Luminosity Monitor. A spectrum with an $^{241}Am$ source has been acquired, with beams circulating in the main rings, and peak resolutions of 6% at 60 keV and of 2.2% at 511 keV have been achieved. The background suppression factor, which turned out to be of the order of $\simeq10^{5-6}$, opens the possibility to plan for future kaonic atom measurements with CdZnTe detectors.

physics.ins-det

Measurement of the $K_S \to πe ν$ branching fraction with the KLOE experiment

The branching fraction for the decay $K_S \to πe ν$ has been measured with a sample of 300 million $K_S$ mesons produced in $ϕ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider. Signal decays are selected by a boosted decision tree built with kinematic variables and time-of-flight measurements. Data control samples of $K_L \to πe ν$ decays are used to evaluate signal selection efficiencies. A fit to the reconstructed electron mass distribution finds 49647$\pm$316 signal events. Normalising to the $K_S \to π^+π^-$ decay events the result for the branching fraction is $\mathcal{B}(K_S \to πe ν) = (7.211 \pm 0.046_{\rm stat} \pm 0.052_{\rm syst}) \times10^{-4}$. The combination with our previous measurement gives $\mathcal{B}(K_S \to πe ν) = (7.153 \pm 0.037_{\rm stat} \pm 0.043_{\rm syst}) \times10^{-4}$. From this value we derive $f_+(0)|V_{us}| = 0.2170 \pm 0.009$.

hep-ex

Direct tests of T, CP, CPT symmetries in transitions of neutral K mesons with the KLOE experiment

Tests of the T, CP and CPT symmetries in the neutral kaon system are performed by the direct comparison of the probabilities of a kaon transition process to its symmetry-conjugate. The exchange of in and out states required for a genuine test involving an anti-unitary transformation implied by time-reversal is implemented exploiting the entanglement of $K^0\bar{K}{}^0$ pairs produced at a $ϕ$-factory. A data sample collected by the KLOE experiment at DA$Φ$NE corresponding to an integrated luminosity of about 1.7 fb$^{-1}$ is analysed to study the $Δ$t distributions of the $ϕ\to K_{S}K_{L}\to π^+π^- \: π^{\pm}e^{\mp}ν$ and $ϕ\to K_{S}K_{L}\to π^{\pm}e^{\mp}ν\: 3π^0$ processes, with $Δ$t the difference of the kaon decay times. A comparison of the measured $Δ$t distributions in the asymptotic region $Δt \gg τ_{S}$ allows to test for the first time T and CPT symmetries in kaon transitions with a precision of few percent, and to observe CP violation with this novel method.

hep-ex

Studies of the linearity and stability of Silicon Drift Detectors for kaonic atoms X-ray spectroscopy

The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in terms of linearity and stability. The paper presents preliminary results for the linearity determination and stability monitoring of the SDDs system during the measurement of kaonic deuterium carried out in the summer of 2022.

physics.ins-det

First tests of the full SIDDHARTA-2 experimental apparatus with a 4 He gaseous target

In this paper, we present the first tests performed after the full installation of the SIDDHARTA-2 experimental apparatus on the Interaction Region of the DAΦNE collider at the INFN National Laboratories of Frascati. Before starting the first measurement of the kaonic deuterium 2p{\rightarrow}1s transition, accurate evaluation of the background rejection. mainly achieved with the Kaon Trigger system, was required. This run, performed in the period 04-26/05/2022 with a 4 He gaseous target, confirmed the 10^5 rejection factor obtained with a reduced version of the setup and different machine conditions in 2021. This important outcome motivated the filling of the target cell with deuterium and the starting of the measurement campaign of the kaonic deuterium 2p{\rightarrow}1s transition.

physics.ins-det

Precision tests of Quantum Mechanics and CPT symmetry with entangled neutral kaons at KLOE

The quantum interference between the decays of entangled neutral kaons is studied in the process $ϕ\rightarrow K_S K_L \rightarrowπ^+π^-π^+π^-$, which exhibits the characteristic Einstein--Podolsky--Rosen correlations that prevent both kaons to decay into $π^+π^-$ at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon pair state, and to search for tiny decoherence and CPT violation effects, which may be justified in a quantum gravity framework. The analysed data sample was collected with the KLOE detector at DA$Φ$NE, the Frascati $ϕ$-factory, and corresponds to an integrated luminosity of about 1.7 fb$^{-1}$, i.e. to about $1.7 \times 10^9$ $ϕ\rightarrow K_S K_L$ decays produced. From the fit of the observed $Δt$ distribution, being $Δt$ the difference of the kaon decay times, the decoherence and CPT violation parameters of various phenomenological models are measured with a largely improved accuracy with respect to previous analyses. The results are consistent with no deviation from quantum mechanics and CPT symmetry, while for some parameters the precision reaches the interesting level at which -- in the most optimistic scenarios -- quantum gravity effects might show up. They provide the most stringent limits up to date on the considered models.

hep-ex

The J-PET detector -- a tool for precision studies of ortho-positronium decays

The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events is based on the measurement of the photons energies. In this article we show that the J-PET tomograph system is capable of exclusive measurements of the decays of ortho-positronium atoms. We present the first positronium production results, its lifetime distribution measurements and discuss estimation of the influence of various background sources. The tomograph s performance demonstrated here makes it suitable for precision studies of positronium decays including entanglement of the final state photons, positron annihilation lifetime spectroscopy plus molecular imaging diagnostics.

physics.ins-det

Upper limit on the $η\toπ^{+}π^{-}$ branching fraction with the KLOE experiment

Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$Φ$NE, the Frascati $ϕ$-factory, a search for the $P$- and $CP$-violating decay $η\toπ^{+}π^{-}$ has been performed. Radiative $ϕ\toηγ$ decay is exploited to access the $η$ mesons. No signal is observed in the $π^{+}π^{-}$ invariant mass spectrum, and the upper limit on the branching fraction at 90\% confidence level is determined to be ${\mathcal B}(η\toπ^{+}π^{-})<4.9\times10^{-6}$, which is approximately three times smaller than the previous KLOE result. From the combination of these two measurements we get ${\mathcal B}(η\toπ^{+}π^{-}) < 4.4\times10^{-6}$ at 90\% confidence level.

hep-ex