Close to threshold eta' meson production in proton-proton collisions at COSY-11

Intensive quest for the eta and eta' bound states is currently ongoing at both theoretical and experimental levels e.g. at COSY, ELSA, GSI, JINR, JPARC, LPI, and MAMI. These studies were already supported by data provided by the COSY-11 collaboration including determination of the total width of the eta' meson. In addition, the first rough estimation of the eta'-N interaction from the excitation function of the cross section for the pp-->pp eta' reaction was also performed. Recent precise measurement in this field from the COSY-11 experiment allows to summarize results on the eta' meson production cross section in proton-proton collisions at COSY-11.

nucl-ex↗

Study of Dalitz decay phi -> eta e+e- with KLOE detector

We have studied the vector to pseudoscalar conversion decay phi -> eta e+e-, with eta -> pi0pi0pi0, with the KLOE detector at DAPHNE. The data set of 1.7 fb-1 of e+e- collisions at sqrt(s)~Mphi contains a clear conversion decay signal of ~31,000 events from which we measured a value of BR(phi -> eta e+e-)=(1.075+-0.007+-0.038)x10-4. The same sample is used to determine the transition form factor by a fit to the e+e- invariant mass spectrum, obtaining b(phi eta) =(1.17 +- 0.10 + 0.07) GeV-2, that improves by a factor of five the precision of the previous measurement and is in good agreement with VMD expectations.

hep-ex↗

Test of a single module of the J-PET scanner based on plastic scintillators

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to sigma(E)/E = 0.044/sqrt(E[MeV]) and corresponds to the sigma(E)/E of 7.5% at the Compton edge.

physics.ins-det↗

Search for light vector boson production in $e^+e^- \rightarrow μ^+ μ^- γ$ interactions with the KLOE experiment

We have searched for a light vector boson $U$, the possible carrier of a "dark force", with the KLOE detector at the DA$Φ$NE \epm\ collider, motivated by astrophysical evidence for the presence of dark matter in the universe. Using \epm\ collisions collected with an integrated luminosity of $239.3$~pb$^{-1}$, we look for a dimuon mass peak in the reaction \epm\to$μ^+ μ^-$\gam, corresponding to the decay $U\toμ^+μ^-$. We find no evidence for a $U$ vector boson signal. We set a 90\% CL upper limit for the mixing parameter squared between the photon and the $U$ boson of 1.6$\times$10$^{-5}$ to 8.6$\times$10$^{-7}$ for the mass region $520<m_{\rm U}<980$ MeV.

hep-ex↗

Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 ps

physics.ins-det↗

Determination of the eta'-proton scattering length in free space

Taking advantage of both the high mass resolution of the COSY-11 detector and the high energy resolution of the low-emittance proton-beam of the Cooler Synchrotron COSY we determine the excitation function for the pp --> pp eta' reaction close-to-threshold. Combining these data with previous results we extract the scattering length for the eta'-proton potential in free space to be Re(a_{p eta'}) = 0+-0.43 fm and Im(a_{p eta'}) = 0.37(+0.40)(-0.16) fm.

nucl-ex↗

Study of the N N eta' production with COSY-11

We describe a new high precision measurement of the production cross-section for the eta' meson in proton-proton collisions for five beam momenta at low access energy region Q conducted at the COSY-11 detection system together with an updated results of all other previous measurements of cross-section for (pp-->pp eta') at COSY-11.

nucl-ex↗

Combined analysis of the $K^{+}K^{-}$ interaction using near threshold $pp \to ppK^+K^-$ data

The $K^{+}K^{-}$ final state interaction was investigated based on both the $K^{+}K^{-}$ invariant mass distributions measured at excess energies of Q = 10 and 28 MeV and the near threshold excitation function for the $pp \to ppK^{+}K^{-}$ reaction. The $K^+K^-$ final state enhancement factor was parametrized using the effective range expansion. The effective range of the $K^+K^-$ interaction was estimated to be: $\mathrm{Re}(b_{K^{+}K^{-}}) = -0.1 \pm 0.4_{stat} \pm 0.3_{sys} \mathrm{fm}$ and $\mathrm{Im}(b_{K^{+}K^{-}}) = 1.2^{+0.1_{stat}+0.2_{sys}}_{-0.2_{stat}-0.0_{sys}} \mathrm{fm}$, and the determined real and imaginary parts of the $K^+K^-$ scattering length amount to: $|\mathrm{Re}(a_{K^{+}K^{-}})| = 8.0^{+6.0_{stat}}_{-4.0_{stat}} \mathrm{fm}$ and $\mathrm{Im}(a_{K^{+}K^{-}}) = 0.0^{+20.0_{stat}}_{-5.0_{stat}} \mathrm{fm}$.

hep-ph↗

Test of CPT and Lorentz symmetry in entangled neutral kaons with the KLOE experiment

Neutral kaon pairs produced in phi decays in anti-symmetric entangled state can be exploited to search for violation of CPT symmetry and Lorentz invariance. We present an analysis of the CP-violating process phi->K_S K_L->pi+pi-pi+pi- based on 1.7 fb-1 of data collected by the KLOE experiment at the Frascati phi-factory DAFNE. The data are used to perform a measurement of the CPT-violating parameters Delta_amu for neutral kaons in the contest of the Standard Model Extension framework. The parameters measured in the reference frame of the fixed stars are: Delta_ao = (-6.0 +- 7.7_{stat} +- 3.1_{syst}) x 10^{-18} GeV Delta_ax = ( 0.9 +- 1.5_{stat} +- 0.6_{syst}) x 10^{-18} GeV Delta_ay = (-2.0 +- 1.5_{stat} +- 0.5_{syst}) x 10^{-18} GeV Delta_az = ( 3.1 +- 1.7_{stat} +- 0.5_{syst}) x 10^{-18} GeV These are presently the most precise measurements in the quark sector of the Standard Model Extension.

hep-ex↗

A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays

All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present methods and it is well suited for newly developed TOF-PET scanners with a large longitudinal field of view. The method enables also monitoring of the quality of the scintillator materials and in general allows for the continuous quality assurance of the PET detector performance.

physics.ins-det↗

J-PET analysis framework for the prototype TOF-PET detector

Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics of the Jagiellonian University. This software is based on the ROOT package used in many particle physics experiments.

physics.ins-det↗

Determination of the map of efficiency of the J-PET detector with the GATE package

A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.

physics.ins-det↗

Database and data structure for the novel TOF-PET detector developed for J-PET project

The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: registration process of the gamma quanta emitted from positron-electron annihilation, Front-End Electronic (FEE) structure and required input information for the image reconstruction. In addition, the system database fulfills possible demands of the evolving J-PET project.

physics.ins-det↗

Computing support for advanced medical data analysis and imaging

We discuss computing issues for data analysis and image reconstruction of PET-TOF medical scanner or other medical scanning devices producing large volumes of data. Service architecture based on the grid and cloud concepts for distributed processing is proposed and critically discussed.

physics.comp-ph↗

Phenomenology of the $ppK^+K^-$ system near threshold

In this article studies of the near threshold $pp\to ppK^+K^-$ reaction conducted with the COSY-11 and the ANKE detectors are reviewed. In particular recent investigations on the $K^+K^-$ final state interaction are revisited taking into account updated cross sections of the COSY-11 experiment. These studies resulted in the new value of $K^+K^-$ effective range amounting to: $\mathrm{Re}(b_{K^{+}K^{-}}) = -0.2^{+0.8_{stat}~+0.4_{sys}}_{-0.6_{stat}~-0.4_{sys}}~\mathrm{fm}$ and $\mathrm{Im}(b_{K^{+}K^{-}}) = 1.2^{~+0.5_{stat}~+0.3_{sys}}_{~-0.3_{stat}~-0.3_{sys}}~\mathrm{fm}$. The determined real and imaginary parts of the $K^+K^-$ scattering length were estimated to be: $\left|\mathrm{Re}(a_{K^{+}K^{-}})\right| = 10^{~+17_{stat}}_{~-10_{stat}}~\mathrm{fm}$ and $\mathrm{Im}(a_{K^{+}K^{-}}) = 0^{~+37_{stat}}_{~-10_{stat}}~\mathrm{fm}$.

nucl-ex↗

Calibration of photomultipliers gain used in the J-PET detector

Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we describe single photoelectron method used for photomultipliers calibration applied for J-PET scanner, a novel PET detector being developed at the Jagiellonian University. Description of calibration method, an example of calibration curve and gain of few R4998 Hamamatsu photomultipliers are presented.

physics.ins-det↗

Simulations of gamma quanta scattering in a single module of the J-PET detector

This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the scintillator strip with the cross section of 5 mm x 19 mm. Obtained results indicate that secondary interactions occur only in the case of about 8% of events and out of them only 25$\%$ take place in the distance larger than 0.5 cm from the primary interaction. It was also established that light signals produced at primary and secondary interactions overlap with the delay which distribution is characterized by FWHM of about 40 ps.

physics.ins-det↗