SearcharxivSearch

arXiv subjects

M. Silveira

Publications and source records attributed to M. Silveira.

2 recordsLinked to original sources

Remeasurement of the $^{239}$Pu(n,f)/$^{235}$U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber Using Vapor-deposited Targets

The NIFFTE fission Time Projection Chamber (fissionTPC) has been used to measure the $^{239}$Pu(n,f)/$^{235}$U(n,f) cross-section ratio for neutron-induced fission in the range of 0.1 - 100 MeV, with high precision. A white neutron source was provided by the Los Alamos Neutron Science Center, where the experiment was conducted as a remeasurement to evaluate a roughly 2% discrepancy of the previous fissionTPC results with ENDF/B-VIII.0. A detailed accounting of measurement uncertainties was performed, based on the fissionTPC's novel ability to provide three-dimensional reconstruction of fission-fragment ionization profiles. Current results obtained using a vapor-deposited, highly uniform $^{239}$Pu target, in comparison to the measurement published in 2021, where a $^{239}$Pu electroplated target was used, are presented and discussed. The remeasurement presented here is in agreement with the previous fissionTPC result within measurement uncertainties.

nucl-ex

TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector

The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.

physics.ins-det