Searcharxiv⌕ Search

arXiv subjects

M. Sisti

Publications and source records attributed to M. Sisti.

68 records · Page 4Linked to original sources

CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background

The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS (Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE experiment. In this work the results of the first 5 validation runs are presented. Results have been obtained for bulk contaminations and surface contaminations from several nuclides. An extrapolation to the CUORE background has been performed.

nucl-ex↗

Search for beta plus/EC double beta decay of 120Te

We present a search for beta plus/EC double beta decay of 120Te performed with the CUORICINO experiment, an array of TeO2 cryogenic bolometers. After collecting 0.0573 kg y of 120Te, we see no evidence of a signal and therefore set the following limits on the half-life: T1/2 (0nu) > 1.9 10^{21} y at 90% C.L. for the 0 neutrino mode and T1/2 (2nu) > 7.6 10^{19} y at 90% C.L. for the two neutrino mode. These results improve the existing limits by almost three orders of magnitude (four in the case of 0 neutrino mode).

nucl-ex↗

130Te Neutrinoless Double-Beta Decay with CUORICINO

We report the final result of the CUORICINO experiment. Operated between 2003 and 2008, with a total exposure of 19.75 kg y of 130Te, CUORICINO was able to set a lower bound on the 130Te 0nDBD half-life of 2.8 10^{24} years at 90% C.L. The limit here reported includes the effects of systematic uncertainties that are examined in detail in the paper. The corresponding upper bound on the neutrino Majorana mass is in the range 300--710 meV, depending on the adopted nuclear matrix element evaluation.

nucl-ex↗

Muon-induced backgrounds in the CUORICINO experiment

To better understand the contribution of cosmic ray muons to the CUORICINO background, 10 plastic scintillator detectors were installed at the CUORICINO site and operated during the final 3 months of the experiment. From these measurements, an upper limit of 0.0021 counts/(keV kg yr) (95% CL) was obtained on the cosmic ray-induced background in the neutrinoless double beta decay region of interest. The measurements were also compared to Geant4 simulations.

nucl-ex↗

Production of high purity TeO2 single crystals for the study of neutrinoless double beta decay

High purity TeO2 crystals are produced to be used for the search for the neutrinoless double beta decay of 130Te. Dedicated production lines for raw material synthesis, crystal growth and surface processing were built compliant with radio-purity constraints specific to rare event physics experiments. High sensitivity measurements of radio-isotope concentrations in raw materials, reactants, consumables, ancillaries and intermediary products used for TeO2 crystals production are reported. Production and certification protocols are presented and resulting ready-to-use TeO2 crystals are described.

cond-mat.mtrl-sci↗

Results from a search for the $0νββ$-decay of $^{130}Te$

A detailed description of the CUORICINO $^{130}Te$ neutrinoless double-beta ($\nbb$) decay experiment is given and recent results are reported. CUORICINO is an array of 62 tellurium oxide ($TeO_{2}$) bolometers with an active mass of 40.7 kg. It is cooled to $\sim 8-10$ mK by a dilution refrigerator shielded from environmental radioactivity and energetic neutrons. It is running in the Laboratori Nazionali del Gran Sasso (LNGS) in Assergi, Italy. These data represent an exposure of $11.83\textrm{kg}...\textrm{y}$ or 91 mole-years of $^{130}Te$. No evidence for $\nbb$-decay was observed and a limit of $T^{0ν}_{1/2}(^{130}Te)\geq3.0\times10^{24}$ y (90% C.L.) is set. This corresponds to an upper limit on the effective mass, $< m_ν>$, between 0.19 and 0.68 eV when analyzed with the many published nuclear structure calculations. In the context of these nuclear models, the values fall within the range corresponding to the claim of evidence of $\nbb$-decay by H.V. Klapdor-Kleingrothaus, \textit{et al.} The experiment continues to acquire data.

hep-ex↗

Fracture Processes Observed with A Cryogenic Detector

In the early stages of running of the CRESST dark matter search using sapphire detectors at very low temperature, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced to fracture events in the sapphire due to the very tight clamping of the detectors. During extensive runs the energy and time of each event was recorded, providing large data sets for such phenomena. We believe this is the first time the energy release in fracture has been directly and accurately measured on a microscopic event-by-event basis. The energy threshold corresponds to the breaking of only a few hundred covalent bonds, a sensitivity some orders of magnitude greater than that of previous technique. We report some features of the data, including energy distributions, waiting time distributions, autocorrelations and the Hurst exponent. The energy distribution appear to follow a power law, $dN/dE\propto E^{-β}$, similar to the power law for earthquake magnitudes, and after appropriate translation, with a similar exponent. In the time domain,the waiting time $w$ or gap distribution between events has a power law behavior at small $w$ and an exponential fall-off at large $w,$ and can be fit $\propto w^{-α}e^{-w/w_0}$. The autocorrelation function shows time correlations lasting for substantial parts of an hour. An asymmetry is found around large events, with higher count rates after, as opposed to before,the large event .

physics.ins-det↗

The Microcalorimeter Arrays for a Rhenium Experiment (MARE): a next-generation calorimetric neutrino mass experiment

Neutrino oscillation experiments have proved that neutrinos are massive particles, but can't determine their absolute mass scale. Therefore the neutrino mass is still an open question in elementary particle physics. An international collaboration is growing around the project of Microcalorimeter Arrays for a Rhenium Experiment (MARE) for directly measuring the neutrino mass with a sensitivity of about 0.2eV/c2. Many groups are joining their experiences and technical expertise in a common effort towards this challenging experiment. We discuss the different scenarios and the impact of MARE as a complement of KATRIN.

hep-ex↗

A New Limit on the Neutrinoless DBD of 130Te

We report the present results of CUORICINO a cryogenic experiment on neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62 crystals of TeO2 with a total active mass of 40.7 kg. The array is framed inside of a dilution refrigerator, heavily shielded against environmental radioactivity and high-energy neutrons, and operated at a temperature of ~8 mK in the Gran Sasso Underground Laboratory. Temperature pulses induced by particle interacting in the crystals are recorded and measured by means of Neutron Transmutation Doped thermistors. The gain of each bolometer is stabilized with voltage pulses developed by a high stability pulse generator across heater resistors put in thermal contact with the absorber. The calibration is performed by means of two thoriated wires routinely inserted in the set-up. No evidence for a peak indicating neutrinoless DBD of 130Te is detected and a 90% C.L. lower limit of 1.8E24 years is set for the lifetime of this process. Taking largely into account the uncertainties in the theoretical values of nuclear matrix elements, this implies an upper boud on the effective mass of the electron neutrino ranging from 0.2 to 1.1 eV. This sensitivity is similar to those of the 76Ge experiments.

hep-ex↗

A Calorimetric Search on Double Beta Decay of 130Te

We report on the final results of a series of experiments on double decay of 130Te carried out with an array of twenty cryogenic detectors. The set-up is made with crystals of TeO2 with a total mass of 6.8 kg, the largest operating one for a cryogenic experiment. Four crystals are made with isotopically enriched materials: two in 128Te and two others in 130Te. The remaining ones are made with natural tellurium, which contains 31.7 % and 33.8 % 128Te and 130Te, respectively. The array was run under a heavy shield in the Gran Sasso Underground Laboratory at a depth of about 3500 m.w.e. By recording the pulses of each detector in anticoincidence with the others a lower limit of 2.1E23 years has been obtained at the 90 % C.L. on the lifetime for neutrinoless double beta decay of 130Te. In terms of effective neutrino mass this is the most restrictive limit in direct experiments, after those obtained with Ge diodes. Limits on other lepton violating decays of 130Te and on the neutrinoless double beta decay of 128Te to the ground state of 128Xe are also reported and discussed. An indication is presented for the two neutrino double beta decay of 130Te. Some consequences of the present results in the interpretation of geochemical experiments are discussed.

hep-ex↗

A bolometric measurement of the antineutrino mass

High statistics calorimetric measurements of the beta spectrum of 187Re are being performed with arrays of silver perrhenate crystals operated at low temperature. After a modification of the experimental set-up, which allowed to substantially reduce the background of spurious counts and therefore to increase the sensitivity on the electron antineutrino mass, a new measurement with 10 silver perrhenate microbolometers is running since July 2002. The crystals have masses between 250 and 350 micrograms and their average FWHM energy resolution, constantly monitored by means of fluorescence X-rays, is of 28.3 eV at the beta end-point. The Kurie plot collected during 4485 hours x mg effective running time has an end-point energy of 2466.1 +/- 0.8{stat} +/- 1.5 {syst} eV, while the half lifetime of the decay is found to be 43.2 +/- 0.2{stat} +/- 0.1{syst} Gy. These values are the most precise obtained so far for 187Re. From the fit of the Kurie plot we can deduce a value for the squared electron antineutrino mass m(nu)^2 of 147 +/- 237{stat} +/- 90{syst} eV^2. The corresponding 90% C.L. upper limit for m(nu) is 21.7 eV.

hep-ex↗

CUORE: A Cryogenic Underground Observatory for Rare Events

CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.

hep-ex↗

New Limits on Naturally Occurring Electron Capture of 123Te

Electron capture of 123Te from the K shell has been investigated in a new underground search with an array of 340 g TeO_2 thermal detectors. We find that some previous indication of this decay could be attributed to E.C. of 121Te resulting from neutron activation of natural Tellurium. There is therefore so far no evidence for E.C. of 123Te from the K shell with a 90 % c.l. lower limit t_{1/2}^K > 5.E19 years on the half lifetime. Taking into account the predicted K E.C. branching ratio, the corresponding lower limit on the 123Te EC half lifetime is t_{1/2} > 9.2E16 y, which can be theoretically interpreted only on the basis of a strong suppression of the nuclear matrix elements. A complementary analysis based on the expected fraction of E.C. accompanied by internal bremsstrahlung is discussed.

hep-ex↗

Discrimination between Nuclear Recoils and Electron Recoils by Simultaneous Detection of Phonons and Scintillation Light

We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass of 6g as scintillating absorber, we have achieved a discrimination of nuclear recoils against electron recoils with a suppression factor of 99.7% at energies above 15 keV. This novel method will be applied for background rejection in the CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) experiment looking for dark matter Weakly Interacting Massive Particles (WIMPs).

physics.ins-det↗