SearcharxivSearch

arXiv subjects

M. Slater

Publications and source records attributed to M. Slater.

4 recordsLinked to original sources

Accelerating Garfield++ with CUDA

Garfield++ is extensively used within the gaseous detector community for comprehensive detector simulations, supporting the full experimental life cycle from design to operation and calibration. The emergence of micro-pattern gaseous detectors has necessitated computationally intensive microscopic avalanche simulations. The acceleration of one of Garfield++'s most demanding algorithms, AvalancheMicroscopic, by porting it to graphics processing units using NVIDIA's CUDA framework is described. The modifications are integrated into the Garfield++ codebase and are accessible to end users with only minor adjustments to their existing code. Benchmark results demonstrate substantial speed-up, especially for high-gain avalanches involving thousands of electrons, thereby enabling more efficient and detailed detector simulations.

physics.ins-det

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider

The International Linear Collider and other proposed high energy e+ e- machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 1e-4. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006--2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5e-4 was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

physics.acc-ph

Cavity BPM System Tests for the ILC Spectrometer

The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of $10^{-4}$ or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 hours for a $1\m$ long BPM triplet. We find micron-level stability over 1 hour for 3 BPM stations distributed over a $30\m$ long baseline. The understanding of the behaviour and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.

physics.ins-det

A Test Facility for the International Linear Collider at SLAC End Station A, for Prototypes of Beam Delivery and IR Components

The SLAC Linac can deliver damped bunches with ILC parameters for bunch charge and bunch length to End Station A. A 10Hz beam at 28.5 GeV energy can be delivered there, parasitic with PEP-II operation. We plan to use this facility to test prototype components of the Beam Delivery System and Interaction Region. We discuss our plans for this ILC Test Facility and preparations for carrying out experiments related to collimator wakefields and energy spectrometers. We also plan an interaction region mockup to investigate effects from backgrounds and beam-induced electromagnetic interference.

physics.ins-det