SearcharxivSearch

arXiv subjects

M. Steidl

Publications and source records attributed to M. Steidl.

16 recordsLinked to original sources

GPU-based optical simulation of the DARWIN detector

Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

physics.ins-det

Forward Beam Monitor for the KATRIN experiment

The \textit{KArlsruhe TRItium Neutrino} (KATRIN) experiment aims to measure the neutrino mass with a sensitivity of \SI{0.2}{\electronvolt} (\SI{90}{\percent} CL). This will be achieved by a precision measurement of the endpoint region of the $\upbeta$-electron spectrum of tritium decay. The $\upbeta$-electrons are produced in the \textit{Windowless Gaseous Tritium Source} (WGTS) and guided magnetically through the beamline. In order to accurately extract the neutrino mass the source activity is required to be stable and known to a high precision. The WGTS therefore undergoes constant extensive monitoring from several measurement systems. The \textit{Forward Beam Monitor} (FBM) is one such monitoring system. The FBM system comprises a complex mechanical setup capable of inserting a detector board into the KATRIN beamline with a positioning precision of better than \SI{0.3}{\milli\metre}. The electron flux density at that position is on the order of \SI{e6}{\per\second\per\milli\metre\squared}. The detector board contains two silicon detector chips of \pin diode type which can measure the $\upbeta$-electron flux from the source with a precision of \SI{0.1}{\percent} within \SI{60}{\second} with an energy resolution of FWHM $=$ \SI{2}{\kilo\electronvolt}. The unique challenge in developing the FBM arise from its designated operating environment inside the Cryogenic Pumping Section which is a potentially tritium contaminated ultra-high vacuum chamber at cryogenic temperatures in the presence of a \SI{1}{\tesla} strong magnetic field. Each of theses parameters do strongly limit the choice of possible materials which e.g. caused difficulties in detector noise reduction, heat dissipation and lubrication. In order to completely remove the FBM from the beam tube a \SI{2}{\meter} long traveling distance into the beamline is needed demanding a robust as well as highly precise moving mechanism.

physics.ins-det

Characterization of Silicon Drift Detectors with Electrons for the TRISTAN Project

Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. A promising model-independent way to search for sterile neutrinos is via high-precision beta spectroscopy. The Karlsruhe Tritium Neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector's response to electrons on the final sterile neutrino sensitivity.

physics.ins-det

Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.

physics.ins-det

Time dependent simulation of the flow reduction of D$_2$ and T$_2$ in the KATRIN experiment

The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to measure the effective electron anti-neutrino mass with an unprecedented sensitivity of 0.2 eV/c$^2$, using beta-electrons from tritium decay. Super-conducting magnets will guide the electrons through a vacuum beam-line from the windowless gaseous tritium source through differential and cryogenic pumping sections to a high resolution spectrometer. At the same time tritium gas has to be prevented from entering the spectrometer. Therefore, the pumping sections have to reduce the tritium flow by at least 14 orders of magnitude. This paper describes various simulation methods in the molecular flow regime used to determine the expected gas flow reduction in the pumping sections for deuterium (commissioning runs) and for radioactive tritium. Simulations with MolFlow+ and with an analytical model are compared with each other, and with the stringent requirements of the KATRIN experiment.

physics.ins-det

Focal-plane detector system for the KATRIN experiment

The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.

physics.ins-det

Wavelet Approach to Search for Sterile Neutrinos in Tritium $β$-Decay Spectra

Sterile neutrinos in the mass range of a few keV are candidates for both cold and warm dark matter. An ad-mixture of a heavy neutrino mass eigenstate to the electron neutrino would result in a minuscule distortion - a 'kink' - in a $β$-decay spectrum. In this paper we show that a wavelet transform is a very powerful shape analysis method to detect this signature. For a tritium source strength, similar to what is expected from the KATRIN experiment, a statistical sensitivity to active-to-sterile neutrino mixing down to $\sin^2 θ= 10^{-6}$ ($90\%$ CL) can be obtained after 3 years of measurement time. It is demonstrated that the wavelet approach is largely insensitive to systematic effects that result in smooth spectral modifications. To make full use of this analysis technique a high resolution measurement (FWHM of $\sim100$~eV) of the tritium $β$-decay spectrum is required.

hep-ph

Sensitivity of Next-Generation Tritium Beta-Decay Experiments for keV-Scale Sterile Neutrinos

We investigate the sensitivity of tritium $β$-decay experiments for keV-scale sterile neutrinos. Relic sterile neutrinos in the keV mass range can contribute both to the cold and warm dark matter content of the universe. This work shows that a large-scale tritium beta-decay experiment, similar to the KATRIN experiment that is under construction, can reach a statistical sensitivity of the active-sterile neutrino mixing of $\sin^2θ\sim 10^{-8}$. The effect of uncertainties in the known theoretical corrections to the tritium $β$-decay spectrum were investigated, and found not to affect the sensitivity significantly. It is demonstrated that controlling uncorrelated systematic effects will be one of the main challenges in such an experiment.

physics.ins-det

Dead layer on silicon p-i-n diode charged-particle detectors

Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-n} diode used in the KATRIN neutrino-mass experiment has such a dead layer. We have constructed a detailed Monte Carlo model for the passage of electrons from vacuum into a silicon detector, and compared the measured energy spectra to the predicted ones for a range of energies from 12 to 20 keV. The comparison provides experimental evidence that a substantial fraction of the ionization produced in the "dead" layer evidently escapes by diffusion, with 46% being collected in the depletion zone and the balance being neutralized at the contact or by bulk recombination. The most elementary model of a thinner dead layer from which no charge is collected is strongly disfavored.

physics.ins-det

Monitoring of the operating parameters of the KATRIN Windowless Gaseous Tritium Source

The Karlsruhe Tritium Neutrino (KATRIN) experiment will measure the absolute mass scale of neutrinos with a sensitivity of $\m_ν$ = 200 meV/c$^2$ by high-precision spectroscopy close to the tritium beta-decay endpoint at 18.6 keV. Its Windowless Gaseous Tritium Source (WGTS) is a beta-decay source of high intensity ($10^{11}$/s) and stability, where high-purity molecular tritium at 30 K is circulated in a closed loop with a yearly throughput of 10 kg. To limit systematic effects the column density of the source has to be stabilised at the 0.1% level. This requires extensive sensor instrumentation and dedicated control and monitoring systems for parameters such as the beam tube temperature, injection pressure, gas composition and others. Here we give an overview of these systems including a dedicated Laser-Raman system as well as several beta-decay activity monitors. We also report on results of the WGTS demonstrator and other large-scale test experiments giving proof-of-principle that all parameters relevant to the systematics can be controlled and monitored on the 0.1% level or better. As a result of these works, the WGTS systematics can be controlled within stringent margins, enabling the KATRIN experiment to explore the neutrino mass scale with the design sensitivity.

physics.ins-det

The KATRIN Pre-Spectrometer at reduced Filter Energy

The KArlsruhe TRItium Neutrino experiment, KATRIN, will determine the mass of the electron neutrino with a sensitivity of 0.2 eV (90% C.L.) via a measurement of the beta-spectrum of gaseous tritium near its endpoint of E_0 =18.57 keV. An ultra-low background of about b = 10 mHz is among the requirements to reach this sensitivity. In the KATRIN main beam-line two spectrometers of MAC-E filter type are used in a tandem configuration. This setup, however, produces a Penning trap which could lead to increased background. We have performed test measurements showing that the filter energy of the pre-spectrometer can be reduced by several keV in order to diminish this trap. These measurements were analyzed with the help of a complex computer simulation, modeling multiple electron reflections both from the detector and the photoelectric electron source used in our test setup.

physics.ins-det

Improved limits on nuebar emission from mu+ decay

We investigated mu+ decays at rest produced at the ISIS beam stop target. Lepton flavor (LF) conservation has been tested by searching for \nueb via the detection reaction p(\nueb,e+)n. No \nueb signal from LF violating mu+ decays was identified. We extract upper limits of the branching ratio for the LF violating decay mu+ -> e+ \nueb νcompared to the Standard Model (SM) mu+ -> e+ nue numub decay: BR < 0.9(1.7)x10^{-3} (90%CL) depending on the spectral distribution of \nueb characterized by the Michel parameter rho=0.75 (0.0). These results improve earlier limits by one order of magnitude and restrict extensions of the SM in which \nueb emission from mu+ decay is allowed with considerable strength. The decay \mupdeb as source for the \nueb signal observed in the LSND experiment can be excluded.

hep-ex

Statistical Analysis of Different Muon-antineutrino->Electron-antineutrino Searches

A combined statistical analysis of the experimental results of the LSND and KARMEN \numubnueb oscillation search is presented. LSND has evidence for neutrino oscillations that is not confirmed by the KARMEN experiment. This joint analysis is based on the final likelihood results for both data sets. A frequentist approach is applied to deduce confidence regions. At a combined confidence level of 36%, there is no area of oscillation parameters compatible with both experiments. For the complementary confidence of 1-0.36=64%, there are two well defined regions of oscillation parameters (sin^2(2th),Dm^2) compatible with both experiments.

hep-ex

Upper limits for neutrino oscillations muon-antineutrino to electron-antineutrino from muon decay at rest

The KARMEN experiment at the spallation neutron source ISIS used \numub from \mup--decay at rest in the search for neutrino oscillations \numubnueb in the appearance mode, with p(\nueb,e+)n as detection reaction of \nueb. In total, 15 candidates fulfill all conditions for the \nueb signature, in agreement with the background expectation of 15.8+-0.5 events, yielding no indication for oscillations. A single event based likelihood analysis leads to upper limits on the oscillation parameters: sin^2(2theta)<1.7x10e-3 for Dm^2>100 eV^2 and Dm^2<0.055 eV^2 for sin^2(2theta)=1 at 90% confidence. Thus, KARMEN does not confirm the LSND experiment and restricts significantly its favored parameter region for \numubnueb.

hep-ex

Measurement of the energy spectrum of ν_e from muon decay and implications for the Lorentz structure of the weak interaction

The KARMEN experiment uses the reaction 12C(ν_e,e-)12N to measure the energy distribution of ν_e emitted in muon decay at rest. The ν_e analog ω_l of the famous Michel parameter ρhas been derived from a maximum-likelihood analysis of events near the kinematic end point, E_max. The result, ω_l = (2.7^{+3.8}_{-3.3}\pm 3.1) * 10^{-2}, is in good agreement with the standard model prediction ω_l= 0. We deduce a 90% confidence upper limit of ω_l <= 0.113, which corresponds to a limit of |g^S_RL + 2 g^T_RL| <= 0.78 on the interference term between scalar and tensor coupling constants.

hep-ex

KARMEN Limits on nu_e -> nu_tau Oscillations in 2-neutrino and 3-neutrino Mixing Schemes

The 56 tonne high resolution liquid scintillation calorimeter KARMEN at the beam stop neutrino source ISIS has been used to search for neutrino oscillations in the disappearance channel nu_e->x. The nu_e emitted in mu+ decay at rest are detected with spectroscopic quality via the exclusive charged current reaction 12-C(nu_e,e-)12-N_g.s. almost free of background. Analysis of the spectral shape of e- from the nu_e induced reaction as well as a measurement of the absolute nu_e flux allow to investigate oscillations of the type nu_e->nu_tau and nu_e->nu_mu . The flux independent ratio R(CC/NC) of charged current events 12-C(nu_e,e-)12-N_g.s. to neutral current events 12-C(nu,nu')12-C* provides additional information in the oscillation channel nu_e->x . All three analysis methods show no evidence for oscillations. For the nu_e->nu_tau channel 90%CL limits of sin^2(2t)<0.338 for dm^2>100eV^2 and dm^2<0.77eV^2 for maximal mixing in a simple 2 flavor oscillation formalism are derived. A complete 3 flavor analysis of the experimental data from five years of measurement with respect to nu_e<->nu_tau and nu_e<->nu_mu mixing is presented.

hep-ex