SearcharxivSearch

arXiv subjects

M. Thiesse

Publications and source records attributed to M. Thiesse.

6 recordsLinked to original sources

Ultra-Low Background Germanium Assay at the Boulby Underground Laboratory

As we move to an era where next generation low-background particle physics experiments begin to be designed and constructed, the ability to assay materials with high sensitivity and at speed with a variety of techniques will be key. This paper describes the Mirion Technologies (Canberra) specialty ultra-low background detectors installed and commissioned at the Boulby Underground Laboratory between 2017 and 2021. The low background levels of the detectors combine with low background shielding and a radon-reduced dry nitrogen purge system to give sensitivity approaching the best in the world without the need for intricate shielding solutions. For an optimised sample geometry, run for 100 days, it would be possible to reach close to 10 $μ$Bq/kg ($10^{-12}$ g/g) for background isotopes of interest in neutrinoless double-beta decay.

physics.ins-det

Improved sensitivity in the search for rare decays of Gd isotopes

Gadolinium is widely used in multiple low-background experiments, making its isotopes accessible for rare decay searches both in-situ and through radiopurity screening data. This study presents an improved search for rare alpha and double-beta decay modes in $^{152}$Gd, $^{154}$Gd, and $^{160}$Gd isotopes using ultra-low background HPGe detectors at the Boulby Underground Screening (BUGS) facility. A total exposure of 6.7 kg$\cdot$yr of natural gadolinium was achieved using gadolinium sulfate octahydrate $(\text{Gd}_2(\text{SO}_4)_3 \cdot 8\text{H}_2\text{O})$ samples, originally screened for radiopurity prior to their deployment in the Super-Kamiokande neutrino experiment. Due to the detection methodology, only decays into excited states accompanied by gamma-ray emission were accessible. A Bayesian analysis incorporating prior experimental results was employed, leading to new lower half-life limits in the range of $10^{19} - 10^{21}$ years - an improvement of approximately two orders of magnitude over previous constraints. No statistically significant decay signals were observed. These results demonstrate the effectiveness of repurposing large-scale radiopurity screening campaigns for fundamental physics research.

nucl-ex

Background Shielding by Dense Samples in Low-Level Gamma Spectrometry

In low activity gamma spectrometric measurements of large, dense samples, the bulk sample material shields the HPGe crystal from external background sources. If not accounted for in studies that utilise background-subtraction methods, this effect may result in systematic errors in the sample activity and detection limit estimation. We introduce a Monte Carlo based method to minimise the impact of this effect on sample gamma spectra. It is validated using simulated detector backgrounds and applied to a measurement of low-activity Gd$_2$(SO$_4$)$_3 \cdot$8H$_2$O. One main prerequisite for the correct application of this method is to know in advance the nuclides which contribute to the detector background spectrum and their spatial distribution. With a thorough understanding of the detector backgrounds, the method improves the accuracy of sensitive low-background measurements of low-activity samples. Even without knowing the background sources and their distribution, conservative results may still be presented that account for the potential systematic errors introduced by this background shielding effect.

physics.ins-det

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for "far detectors" of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

physics.ins-det

Evaluation of Gadolinium's Action on Water Cherenkov Detector Systems with EGADS

Used for both proton decay searches and neutrino physics, large water Cherenkov (WC) detectors have been very successful tools in particle physics. They are notable for their large masses and charged particle detection capabilities. While current WC detectors reconstruct charged particle tracks over a wide energy range, they cannot efficiently detect neutrons. Gadolinium (Gd) has the largest thermal neutron capture cross section of all stable nuclei and produces an 8 MeV gamma cascade that can be detected with high efficiency. Because of the many new physics opportunities that neutron tagging with a Gd salt dissolved in water would open up, a large-scale R&D program called EGADS was established to demonstrate this technique's feasibility. EGADS features all the components of a WC detector, chiefly a 200-ton stainless steel water tank furnished with 240 photo-detectors, DAQ, and a water system that removes all impurities in water while keeping Gd in solution. In this paper we discuss the milestones towards demonstrating the feasibility of this novel technique, and the features of EGADS in detail.

physics.ins-det

Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber

The 35-ton prototype for the Deep Underground Neutrino Experiment far detector was a single-phase liquid argon time projection chamber with an integrated photon detector system, all situated inside a membrane cryostat. The detector took cosmic-ray data for six weeks during the period of February 1, 2016 to March 12, 2016. The performance of the photon detection system was checked with these data. An installed photon detector was demonstrated to measure the arrival times of cosmic-ray muons with a resolution better than 32 ns, limited by the timing of the trigger system. A measurement of the timing resolution using closely-spaced calibration pulses yielded a resolution of 15 ns for pulses at a level of 6 photo-electrons. Scintillation light from cosmic-ray muons was observed to be attenuated with increasing distance with a characteristic length of $155 \pm 28$ cm.

physics.ins-det