SearcharxivSearch

arXiv subjects

M. Traxler

Publications and source records attributed to M. Traxler.

At least 19 recordsLinked to original sources

The PANDA Barrel DIRC: From design to assembly

The Barrel DIRC counter will serve as the primary particle identification detector in the PANDA experiment, enabling high-precision hadron physics studies through antiproton-proton annihilations across a momentum range of 1.5 GeV/c to 15 GeV/c. It is designed to distinguish charged pions from kaons with a separation of at least 3 standard deviations up to 3.5 GeV/c within polar angles of 22 degrees to 140 degrees. A lens focusing is used the first time in a DIRC detector. After a successful evaluation in particle beams, the key components, i.e. radiator bars and photon sensors, were purchased and tested.

physics.ins-det

The PANDA Barrel DIRC

The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR), Darmstadt, Germany, will address fundamental questions of hadron physics using $\bar{p}p$ annihilations. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID in the target region will be provided by a Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter. The Barrel DIRC, covering the polar angle range of 22-140 degrees, will provide a $π/K$ separation power of at least 3 standard deviations for charged particle momenta up to 3.5 GeV/c. The design of the Barrel DIRC features narrow radiator bars made from synthetic fused silica, an innovative multi-layer spherical lens focusing system, a prism-shaped synthetic fused silica expansion volume, and an array of lifetime-enhanced Microchannel Plate PMTs (MCP-PMTs) to detect the hit location and arrival time of the Cherenkov photons. Detailed Monte-Carlo simulations were performed, and reconstruction methods were developed to study the performance of the system. All critical aspects of the design and the performance were validated with system prototypes in a mixed hadron beam at the CERN PS. In 2020 the PANDA Barrel DIRC project advanced from the design stage to component fabrication. The series production of the fused silica bars was successfully completed in 2021 and delivery of the MCP-PMTs started in May 2022.

hep-ex

Lifetime and performance of the very latest microchannel-plate photomultipliers

The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an $\sim$1 T magnetic field will be used in the experiment. The only suitable photon detectors for both DIRCs were identified to be Microchannel-Plate Photomultipliers (MCP-PMTs). Since the aging problems of MCP-PMTs were solved recently by coating the MCPs with the so-called ALD-technique (atomic layer deposition) we are investigating devices which are significantly improved with respect to other parameters, as, e.g., the collection efficiency (CE) and the quantum efficiency (QE). The latest generation of MCP-PMTs can reach a detective quantum efficiency DQE = QE - CE of 30%. This paper will present the performance of the most advanced 53 $\times$ 53 mm$^2$ ALD-coated MCP-PMTs from Photonis (8 $\times$ 8 and 3 $\times$ 100 anodes) and Photek (8 $\times$ 8 anodes), also inside the magnetic field. With a picosecond laser and a multi-hit capable DAQ system which allows read out up to 300 pixels simultaneously, parameters like darkcount rate, afterpulse probability and time resolution can be investigated as a function of incident photon position.

physics.ins-det

Performance of the most recent Microchannel-Plate PMTs for the PANDA DIRC detectors at FAIR

In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $π$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent requirements like high detection efficiency, low dark count rate, radiation hardness, long lifetime and good timing, MCP-PMTs (microchannel-plate photomultiplier) were the best choice of photon sensors for the DIRC detectors in the PANDA experiment. This paper will present the performance of some of the latest 2$\times$2 inch$^2$ MCP-PMTs from Photek and Photonis, including the first mass production tubes for the PANDA Barrel DIRC from Photonis. Performance parameters like the collection efficiency (CE), quantum efficiency (QE), and gain homogeneity were determined. The effect of magnetic fields on some properties like gain and charge cloud width was investigated as well. Apart from that the spatial distribution of many internal parameters like time resolution, dark count rate, afterpulse ratio, charge sharing crosstalk and recoil electrons were measured simultaneously with a multihit capable DAQ system. The latest generation of Photonis MCP-PMTs shows an unexpected "escalation" effect where the MCP-PMT itself produces photons.

physics.ins-det

Investigation of the $\mathbf{Σ^{0}}$ Production Mechanism in p(3.5 GeV)+p Collisions

The production of $Σ^0$ hyperons in proton proton collisions at a beam kinetic energy of 3.5 GeV impinging on a liquid hydrogen target was investigated using data collected with the HADES setup. The total production cross section is found to be $\mathrm{σ(pK^{+}Σ^{0}) [μb] = 17.7 \pm 1.7 (stat) \pm 1.6 (syst)}$. Differential cross section distributions of the exclusive channel $\mathrm{pp \rightarrow pK^{+}Σ^{0}}$ were analyzed in the center-of-mass, Gottfried-Jackson and helicity reference frames for the first time at the excess energy of 556 MeV. The data support the interplay between pion and kaon exchange mechanisms and clearly demonstrate the contribution of interfering nucleon resonances decaying to $\mathrm{K^{+}Σ^{0}}$. The Bonn-Gatchina partial wave analysis was employed to analyse the data. Due to the limited statistics, it was not possible to obtain an unambiguous determination of the relative contribution of intermediate nucleon resonances to the final state. However nucleon resonances with masses around 1.710 $\mathrm{GeV/c^{2}}$ ($\mathrm{N^{*}(1710)}$) and 1.900 $\mathrm{GeV/c^{2}}$ ($\mathrm{N^{*}(1900)}$ or $\mathrm{Δ^{*}(1900)}$) are preferred by the fit.

nucl-ex

Production of hydrogen isotopes and charged pions in p (3.5 GeV) + Nb reactions

The double differential production cross sections, $d^2σ/dΩdE$, for hydrogen isotopes and charged pions in the reaction of p + Nb at 3.5 GeV proton beam energy have been measured by the High Acceptance DiElectron Spectrometer (HADES). Thanks to the high acceptance of HADES at forward emission angles and usage of its magnetic field, the measured energy range of hydrogen isotopes could be significantly extended in comparison to the relatively scarce experimental data available in the literature. The data provide information about the development of the intranuclear cascade in the proton-nucleus collisions. They can as well be utilized to study the rate of energy/momentum dissipation in the nuclear systems and the mechanism of elementary and composite particle production in excited nuclear matter at normal density. Data of this type are important also for technological and medical applications. Our results are compared to models developed to describe the processes relevant to nuclear spallation (INCL++) or oriented to probe either the elementary hadronic processes in nuclear matter or the behavior of compressed nuclear matter (GiBUU).

nucl-ex

Resistive Plate Chambers for Precise Measurement of High-Momentum Protons in Short Range Correlations at R$^3$B

The Reactions with Relativistic Radioactive Beams (R$^3$B) collaboration of the Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany, has constructed an experimental setup to perform fundamental studies of nuclear matter, using as a probe reactions with exotic nuclei at relativistic energies. Among the various detection systems, one of the most recent upgrades consisted on the installation of a large area, around 2 m$^2$, multi-gap Resistive Plate Chamber (RPC), equipped with twelve 0.3 mm gaps and readout by 30 mm pitch strips, exhibiting a timing precision down to 50 ps and efficiencies above 98% for MIPs in a previous characterization of the detector. The RPC was part of the setup of the FAIR Phase 0 experiment that focused on measuring, for the first time, nucleon-nucleon short-range correlations (SRC) inside an exotic nucleus ($^{16}$C) that occurred in Spring 2022. The excellent timing precision of this detector will allow the measurement of the forward emitted proton momentum with a resolution of around 1%. In beam measurements show an RPC efficiency above 95% and a time precision better than 100 ps (including the contribution of a reference scintillator and the momentum spread of the particles) for forward emitted particles.

physics.ins-det

Measurement of global polarization of Λ hyperons in few-GeV heavy-ion collisions

The global polarization of Λ hyperons along the total orbital angular momentum of a relativistic heavy-ion collision is presented based on the high statistics data samples collected in Au+Au collisions at \sqrt{s_{NN}} = 2.4 GeV and Ag+Ag at 2.55 GeV with the High-Acceptance Di-Electron Spectrometer (HADES) at GSI, Darmstadt. This is the first measurement below the strangeness production threshold in nucleon-nucleon collisions. Results are reported as a function of the collision centrality as well as a function of the hyperon transverse momentum (p_T) and rapidity (y_{CM}) for the range of centrality 0--40%. We observe a strong centrality dependence of the polarization with an increasing signal towards peripheral collisions. For mid-central (20--40%) collisions the polarization magnitudes are (%) = 6.8 \pm 1.3 (stat.) \pm 2.1 (syst.) for Au+Au and (%) = 6.2 \pm 0.4 (stat.) \pm 0.6 (syst.) for Ag+Ag, which are the largest values observed so far. This observation thus provides a continuation of the increasing trend previously observed by STAR and contrasts expectations from recent theoretical calculations predicting a maximum in the region of collision energies about 3 GeV. The observed polarization is of a similar magnitude as predicted by 3D fluid dynamics and the UrQMD plus thermal vorticity model and significantly above results from the AMPT model.

nucl-ex

Proton, deuteron and triton flow measurements in Au+Au collisions at $\sqrt{s_{NN}} = 2.4$ GeV

High precision measurements of flow coefficients $v_{n}$ ($n = 1 - 4$) for protons, deuterons and tritons relative to the first-order spectator plane have been performed in Au+Au collisions at $\sqrt{s_{NN}} = 2.4$ GeV with the High-Acceptance Di-Electron Spectrometer (HADES) at the SIS18/GSI. Flow coefficients are studied as a function of transverse momentum $p_{t}$ and rapidity $y_{cm}$ over a large region of phase space and for several classes of collision centrality. A clear mass hierarchy is found for the slope of $v_{1}$, $d v_{1}/d y^{\prime}|_{y^{\prime} = 0}$ where $y^{\prime}$ is the scaled rapidity, and for $v_{2}$ at mid-rapidity. Scaling with the number of nucleons is observed for the $p_{t}$ dependence of $v_{2}$ and $v_{4}$ at mid-rapidity, which is indicative for nuclear coalescence as the main process responsible for light nuclei formation. $v_{2}$ is found to scale with the initial eccentricity $\langle \epsilon_{2} \rangle$, while $v_{4}$ scales with $\langle \epsilon_{2} \rangle^{2}$ and $\langle \epsilon_{4} \rangle$. The multi-differential high-precision data on $v_{1}$, $v_{2}$, $v_{3}$, and $v_{4}$ provides important constraints on the equation-of-state of compressed baryonic matter.

nucl-ex

Performance study and calibration strategy of the HADES scintillator TOF Wall with fast digital readout

We present in this work the calibration procedure and a performance study of long scintillator bars used for the time-of-flight (TOF) measurement in the HADES experiment. The digital front-end electronics installed at the TOF detector required to develop novel calibration methods. The exceptional performance of the spectrometer for particle identification and pointing accuracy allows one to determine in great detail the response of scintillators to minimum ionizing particles. A substantial position sensitivity of the calibration parameters has been found, in particular for the signal time walk. After including the position dependence, the timing accuracy for minimum ionizing particles was improved from 190~ps to 135~ps for the shortest rods (1475 mm) and to 165~ps for the longest (2356 mm). These results are in accordance with the time degradation length of the scintillator bars, as determined from previous measurements.

physics.ins-det

The PANDA DIRCs

The PANDA experiment at the FAIR facility adresses open questions in hadron physics with antiproton beams in the momentum range of 1.5-15 GeV/c. The antiprotons are stored and cooled in a High Energy Storage RING (HESR) with a momentum spread down to Dp/p = 4*10^-5. A high luminosity of up to 2*10^32 cm-2 s-1 can be achieved. An excellent hadronic particle identification (PID) will be provided by two Cherenkov detectors using the priciple of Detection of Internally Reflected Cherenkov light (DIRC). In the forward direction from polar angles of 5 degree to 22 degree, the Endcap Disc DIRC (EDD) separates pions from kaons up to momenta of 4 GeV/c. Between 22 degree and 140 degree the Barrel DIRC cleanly separates pions from kaons for momenta up to 3.5 GeV/c. This article describes the design of the Barrel DIRC and of the Endcap Disc DIRC and the validation of their designs in particle beams at the CERN PS.

physics.ins-det

Time imaging reconstruction for the PANDA Barrel DIRC

The innovative Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter will provide hadronic particle identification (PID) in the central region of the PANDA experiment at the new Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. This detector is designed to separate charged pions and kaons with at least 3 standard deviations for momenta up to 3.5 GeV/c, covering the polar angle range of 22$^{\circ}$-140$^{\circ}$. An array of microchannel plate photomultiplier tubes is used to detect the location and arrival time of the Cherenkov photons with a position resolution of 2 mm and time precision of about 100 ps. The time imaging reconstruction has been developed to make optimum use of the observables and to determine the performance of the detector. This reconstruction algorithm performs particle identification by directly calculating the maximum likelihoods using probability density functions based on detected photon propagation time in each pixel, determined directly from the data, or analytically, or from detailed simulations.

physics.ins-det

Low Gain Avalanche Detectors for the HADES reaction time (T$_0$) detector upgrade

Low Gain Avalanche Detector (LGAD) technology has been used to design and construct prototypes of time-zero detector for experiments utilizing proton and pion beams with High Acceptance Di-Electron Spectrometer (HADES) at GSI Darmstadt, Germany. LGAD properties have been studied with proton beams at the COoler SYnchrotron (COSY) facility in Jülich, Germany. We have demonstrated that systems based on a prototype LGAD operated at room temperature and equipped with leading-edge discriminators reach a time precision below 50 ps. The application in the HADES, experimental conditions, as well as the test results obtained with proton beams are presented.

physics.ins-det

The Pacific Ocean Neutrino Experiment

The Pacific Ocean Neutrino Experiment (P-ONE) is a new initiative with a vision towards constructing a multi-cubic kilometre neutrino telescope, to expand our observable window of the Universe to highest energies, installed within the deep Pacific Ocean underwater infrastructure of Ocean Networks Canada.

astro-ph.HE

A self-monitoring precision calibration light source for large-volume neutrino telescopes

With the rise of neutrino astronomy using large-volume detector arrays, calibration improvements of optical media and photosensors have emerged as significant means to reduce detector systematics. To improve understanding of the detector volume and its instrumentation, we developed an absolutely-calibrated, self-monitoring, isotropic, nanosecond, high-intensity calibration light source called "Precision Optical Calibration Module" (POCAM). This now third iteration of the instrument was developed for an application in the IceCube Upgrade but, with a modular instrument communications and synchronization backend, can provide a calibration light source standard for any large-volume photodetector array. This work summarizes the functional principle of the POCAM and all related device characteristics as well as its precision calibration procedure. The latter provides fingerprint-characterized instruments with knowledge on absolute and relative behavior of the emitted light pulses as well as their temperature dependencies.

astro-ph.IM

Status of the PANDA Barrel DIRC

The PANDA experiment will use cooled antiproton beams with high intensity stored1 in the High Energy Storage Ring at FAIR. Reactions on a fixed target producing charmed hadrons will shed light on the strong QCD. Three ring imaging Cherenkov counters are used for charged particle identification. The status of the Barrel DIRC (Detection of Internally Reflected Cherenkov light) is described. Its design is robust and its performance validated in experiments with test beams. The PANDA Barrel DIRC has entered the construction phase and will be installed in 2023/2024.

physics.ins-det

Particle Identification with DIRCs at PANDA

The DIRC technology (Detection of Internally Reflected Cherenkov light) offers an excellent possibility to minimize the form factor of Cherenkov detectors in hermetic high energy detectors. The PANDA experiment at FAIR in Germany will combine a barrel-shaped DIRC with a disc-shaped DIRC to cover an angular range of 5 to 140 degrees. Particle identification for pions and kaons with a separation power of 3 standard deviations or more will be provided for momenta between 0.5 GeV/c and 3.5 GeV/c in the barrel region and up to 4 GeV/c in the forward region. Even though the concept is simple, the design and construction of a DIRC is challenging. High precision optics and mechanics are required to maintain the angular information of the Cherenkov photons during multiple internal reflections and to focus the individual photons onto position sensitive photon detectors. These sensors must combine high efficiencies for single photons with low dark count rates and good timing resolution at high rates. The choice of radiation hard fused silica for the optical material and of MCP-PMT photon sensors is essential for DIRC detectors to survive in an environment of radiation and strong magnetic field. The two DIRC detectors differ in the focusing optics, in the treatment of chromatic dispersion and in the electronic readout systems. The technical design of the two DIRC detectors and their validation by testing prototypes in a mixed particle beam at CERN are presented.

physics.ins-det

The Innovative Design of the Endcap Disc DIRC Detector for PANDA at FAIR

The key component of the future PANDA experiment at FAIR is a fixed-target detector for collisions of antiprotons with a proton target up to a beam momentum of 15 GeV/c and is designed to address a large number of open questions in the hadron physics sector. In order to guarantee an excellent PID for charged hadrons in the polar angle range between $5^\circ$ and $22^\circ$, a new type of Cherenkov detector called Endcap Disc DIRC (EDD) has been developed for the forward endcap of the PANDA target spectrometer. The desired separation power of at least 3 s.d. for the separation of $π^\pm$ and $K^\pm$ up to particle momenta of 4 GeV/c was determined with simulation studies and validated during various testbeam campaigns at CERN and DESY.

physics.ins-det