SearcharxivSearch

arXiv subjects

M. Vardaro

Publications and source records attributed to M. Vardaro.

3 recordsLinked to original sources

Demonstrating the velocity response of a table-top EPR Speedmeter

The sensitivity of gravitational-wave interferometers is fundamentally limited by quantum noise, as dictated by the Heisenberg uncertainty principle, due to their continuous position measurement of the end mirrors. Speedmeter configurations, which measure mirror velocity rather than position, have been proposed as a means to suppress quantum back-action noise, but practical implementations remain at an early stage. In this work, we present a table-top realisation of the Einstein- Podolsky-Rosen (EPR) Speedmeter concept, employing an optical readout scheme based on two orthogonal polarisation modes that probe the interferometer with different effective bandwidths. Using a triangular cavity, we demonstrate that the differential optical response between the linear p- and s-polarised modes exhibits a speed-like frequency dependence: vanishing at DC and increasing linearly with signal frequency, up to the bandwidth of the slower mode. With this we show that an optical system equivalent to the EPR Speedmeter indeed performs a velocity readout of the end mirror.

astro-ph.IM

All-polarisation beamsplitters for interferometer applications

Optical beamsplitters with similar properties for orthogonal, linear polarisation modes are required for realising polarisation-based speedmeter schemes to reduce back-action noise in gravitational-wave interferometers. In this paper, we investigate two beamsplitter coatings obtained from Laseroptik GmbH and Optoman on a best-effort basis that aim for a 50/50 power splitting ratio and equal overall phase shift for two orthogonal, linear polarisation modes interacting with the optic. We show that while Laseroptik GmbH opted for coating stack with 22 alternating layers of Ta2O5 and SiO2, Optoman produced a much thinner coating made of 5 SiO2 and SiOx (0 < x < 2) layers. With these strategies, the Laseroptik coating achieves an equal power reflectivity of 51% at 46 deg angle of incidence, and zero phase shift between both polarisations at 44.25 deg angle of incidence. The Optoman coating achieves power reflectivities of 49% for s-polarisation and 51% for p-polarisation with a differential phase shift around 5 deg largely independent of the angle of incidence.

physics.optics

Optical losses as a function of beam position on the mirrors in a 285-m suspended Fabry-Perot cavity

Reducing optical losses is crucial for reducing quantum noise in gravitational-wave detectors. Losses are the main source of degradation of the squeezed vacuum. Frequency dependent squeezing obtained via a filter cavity is currently used to reduce quantum noise in the whole detector bandwidth. Such filter cavities are required to have high finesse in order to produce the optimal squeezing angle rotation and the presence of losses is particularly detrimental for the squeezed beam, as it does multiple round trip within the cavity. Characterising such losses is crucial to assess the quantum noise reduction achievable. In this paper we present an in-situ measurement of the optical losses, done for different positions of the beam on the mirrors of the Virgo filter cavity. We implemented an automatic system to map the losses with respect to the beam position on the mirrors finding that optical losses depend clearly on the beam hitting position on input mirror, varying from 42 ppm to 87 ppm, while they are much more uniform when we scan the end mirror (53 ppm to 61 ppm). We repeated the measurements on several days, finding a statistical error smaller than 4 ppm. The lowest measured losses are not much different with respect to those estimated from individual mirror characterisation performed before the installation (30.3 - 39.3 ppm). This means that no major loss mechanism has been neglected in the estimation presented here. The larger discrepancy found for some beam positions is likely to be due to contamination. In addition to a thorough characterisation of the losses, the methodology described in this paper allowed to find an optimal cavity axis position for which the cavity round trip losses are among the lowest ever measured. This work can contribute to achieve the very challenging losses goals for the optical cavities of the future gravitational-wave detectors.

physics.ins-det