SearcharxivSearch

arXiv subjects

M. Vass

Publications and source records attributed to M. Vass.

3 recordsLinked to original sources

Electron power absorption in capacitively coupled neon-oxygen plasmas: a comparison of experimental and computational results

Phase Resolved Optical Emission Spectroscopy (PROES) measurements combined with 1d3v Particle-in-Cell/Monte Carlo Collisions (PIC/MCC) simulations are used to study the electron power absorption and excitation/ionization dynamics in capacitively coupled plasmas (CCPs) in mixtures of neon and oxygen gases. The study is performed for a geometrically symmetric CCP reactor with a gap length of 2.5 cm at a driving frequency of 10~MHz and a peak-to-peak voltage of 350 V. The pressure of the gas mixture is varied between 15 Pa and 500 Pa, while the neon/oxygen concentration is tuned between 10% and 90%. For all discharge conditions, the spatio-temporal distribution of the electron-impact excitation rate from the Ne ground state into the Ne $\rm{2p^53p_0}$ state measured by PROES and obtained from PIC/MCC simulations show good qualitative agreement. Based on the emission/excitation patterns, multiple operation regimes are identified. Localized bright emission features at the bulk boundaries, caused by local maxima in the electronegativity are found at high pressures and high O$_2$ concentrations. The relative contributions of the ambipolar and the Ohmic electron power absorption are found to vary strongly with the discharge parameters: the Ohmic power absorption is enhanced by both the high collisionality at high pressures and the high electronegativity at low pressures. In the wide parameter regime covered in this study, the PROES measurements are found to accurately represent the ionization dynamics, i.e., the discharge operation mode. This work represents also a successful experimental validation of the discharge model developed for neon-oxygen CCPs.

physics.plasm-ph

Electron transport parameters in CO$_2$: scanning drift tube measurements and kinetic computations

This work presents transport coefficients of electrons (bulk drift velocity, longitudinal diffusion coefficient, and effective ionization frequency) in CO2 measured under time-of-flight conditions over a wide range of the reduced electric field, 15Td <= E/N <= 2660Td in a scanning drift tube apparatus. The data obtained in the experiments are also applied to determine the effective steady-state Townsend ionization coefficient. These parameters are compared to the results of previous experimental studies, as well as to results of various kinetic computations: solutions of the electron Boltzmann equation under different approximations (multiterm and density gradient expansions) and Monte Carlo simulations. The experimental data extend the range of E/N compared with previous measurements and are consistent with most of the transport parameters obtained in these earlier studies. The computational results point out the range of applicability of the respective approaches to determine the different measured transport properties of electrons in CO2. They demonstrate as well the need for further improvement of the electron collision cross section data for CO2 taking into account the present experimental data.

physics.plasm-ph

A scanning drift tube apparatus for spatio-temporal mapping of electron swarms

A "scanning" drift tube apparatus, capable of mapping of the spatio-temporal evolution of electron swarms, developing between two plane electrodes under the effect of a homogeneous electric field, is presented. The electron swarms are initiated by photoelectron pulses and the temporal distributions of the electron flux are recorded while the electrode gap length (at a fixed electric field strength) is varied. Operation of the system is tested and verified with argon gas, the measured data are used for the evaluation of the electron bulk drift velocity. The experimental results for the space-time maps of the electron swarms - presented here for the first time - also allow clear observation of deviations from hydrodynamic transport. The swarm maps are also reproduced by particle simulations.

physics.plasm-ph