SearcharxivSearch

arXiv subjects

M. Wade

Publications and source records attributed to M. Wade.

4 recordsLinked to original sources

Toward Low-Latency, High-Fidelity Calibration of the LIGO Detectors with Enhanced Monitoring Tools

Accurate and reliable calibration of the Advanced LIGO detectors has enabled a plethora of gravitational-wave discoveries in the detectors' first decade of operation, starting with the ground-breaking discovery, GW150914. In the first decade of operation, the calibrated strain data from Advanced LIGO detectors has become available at a lower latency and with more reliability. In this paper, we discuss the relevant history of Advanced LIGO calibration and introduce new tools that have been developed to enable faster and more robust calibrated strain data products in the fourth observing run (O4). We discuss improvements to the robustness, reliability, and accuracy of the low-latency calibration pipeline as well as the development of a new tool for monitoring the LIGO detector calibration in real time.

gr-qc

Reconstructing the calibrated strain signal in the Advanced LIGO detectors

Advanced LIGO's raw detector output needs to be calibrated to compute dimensionless strain h(t). Calibrated strain data is produced in the time domain using both a low-latency, online procedure and a high-latency, offline procedure. The low-latency h(t) data stream is produced in two stages, the first of which is performed on the same computers that operate the detector's feedback control system. This stage, referred to as the front-end calibration, uses infinite impulse response (IIR) filtering and performs all operations at a 16384 Hz digital sampling rate. Due to several limitations, this procedure currently introduces certain systematic errors in the calibrated strain data, motivating the second stage of the low-latency procedure, known as the low-latency gstlal calibration pipeline. The gstlal calibration pipeline uses finite impulse response (FIR) filtering to apply corrections to the output of the front-end calibration. It applies time-dependent correction factors to the sensing and actuation components of the calibrated strain to reduce systematic errors. The gstlal calibration pipeline is also used in high latency to recalibrate the data, which is necessary due mainly to online dropouts in the calibrated data and identified improvements to the calibration models or filters.

astro-ph.IM

Improving LIGO calibration accuracy by tracking and compensating for slow temporal variations

Calibration of the second-generation LIGO interferometric gravitational-wave detectors employs a method that uses injected periodic modulations to track and compensate for slow temporal variations in the differential length response of the instruments. These detectors utilize feedback control loops to maintain resonance conditions by suppressing differential arm length variations. We describe how the sensing and actuation functions of these servo loops are parameterized and how the slow variations in these parameters are quantified using the injected modulations. We report the results of applying this method to the LIGO detectors and show that it significantly reduces systematic errors in their calibrated outputs.

astro-ph.IM

The Advanced LIGO Photon Calibrators

The two interferometers of the Laser Interferometry Gravitaional-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events, and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generation (Advanced) LIGO detectors to gravitational waves are systems based on radiation pressure and referred to as Photon Calibrators. These systems, which were completely redesigned for Advanced LIGO, include several significant upgrades that enable them to meet the calibration requirements of second-generation gravitational wave detectors in the new era of gravitational-wave astronomy. We report on the design, implementation, and operation of these Advanced LIGO Photon Calibrators that are currently providing fiducial displacements on the order of $10^{-18}$ m/$\sqrt{\textrm{Hz}}$ with accuracy and precision of better than 1 %.

astro-ph.IM