SearcharxivSearch

arXiv subjects

M. Willers

Publications and source records attributed to M. Willers.

At least 19 recordsLinked to original sources

Description of CRESST-II and CRESST-III pulse shape data

A set of data from 68 cryogenic detectors operated in the CRESST dark matter search experiment between 2013 and 2019 was collected and labeled to train binary classifiers for data cleaning. Here, we describe the data set and how the trained models can be applied to new data. The data and models are available online.

physics.ins-det

Description of CRESST-III lithium aluminate data

Two detector modules with lithium aluminate targets were operated in the CRESST underground setup between February and June 2021. The data collected in this period was used to set the currently strongest cross-section upper limits on the spin-dependent interaction of dark matter (DM) with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$. The data are available online. In this document, we describe how the data set should be used to reproduce our dark matter results.

hep-ex

Optimal operation of cryogenic calorimeters through deep reinforcement learning

Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an expert. In our work, we automated the procedure with reinforcement learning in two settings. First, we trained on a simulation of the response of three CRESST detectors used as a virtual reinforcement learning environment. Second, we trained live on the same detectors operated in the CRESST underground setup. In both cases, we were able to optimize a standard detector as fast and with comparable results as human experts. Our method enables the tuning of large-scale cryogenic detector setups with minimal manual interventions.

physics.ins-det

Detector development for the CRESST experiment

Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of the observations. Within the CRESST collaboration, three new different detector layouts have been developed and they are presented in this contribution.

physics.ins-det

Light Dark Matter Search Using a Diamond Cryogenic Detector

Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. We measured two 0.175 g CVD (Chemical Vapor Deposition) diamond samples, each instrumented with a W-TES. Thanks to the energy threshold of just 16.8 eV of one of the two detectors, we set exclusion limits on the elastic spin-independent interaction of dark matter particles with carbon nuclei down to dark matter masses as low as 0.122 GeV/c2. This work shows the scientific potential of cryogenic detectors made from diamond and lays the foundation for the use of this material as target for direct detection dark matter experiments.

astro-ph.CO

Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment

New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Recently, a new calibration method based on the radiative neutron capture on $^{182}$W with subsequent de-excitation via single $γ$-emission leading to a nuclear recoil peak at 112 eV was proposed. The CRESST-III dark matter search operated several CaWO$_{4}$-based detector modules with detection thresholds below 100 eV in the past years. We report the observation of a peak around the expected energy of 112 eV in the data of three different detector modules recorded while irradiated with neutrons from different AmBe calibration sources. We compare the properties of the observed peaks with Geant-4 simulations and assess the prospects of using this for the energy calibration of CRESST-III detectors.

physics.ins-det

High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model

Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, based on Geant4 simulations, are normalised via a Bayesian likelihood fit to experimental background data. Contrary to our previous work, no assumption of partial secular equilibrium is required, which results in a more robust and versatile applicability. Furthermore, considering the correlation between all background components allows us to explain 82.7% of the experimental background within [1 keV, 40 keV], an improvement of 18.6% compared to our previous method.

physics.ins-det

Results on sub-GeV Dark Matter from a 10 eV Threshold CRESST-III Silicon Detector

We present limits on the spin-independent interaction cross section of dark matter particles with silicon nuclei, derived from data taken with a cryogenic calorimeter with 0.35 g target mass operated in the CRESST-III experiment. A baseline nuclear recoil energy resolution of $(1.36\pm 0.05)$ eV$_{\text{nr}}$, currently the lowest reported for macroscopic particle detectors, and a corresponding energy threshold of $(10.0\pm 0.2)$ eV$_{\text{nr}}$ have been achieved, improving the sensitivity to light dark matter particles with masses below 160 MeV/c$^2$ by a factor of up to 20 compared to previous results. We characterize the observed low energy excess, and we exclude noise triggers and radioactive contaminations on the crystal surfaces as dominant contributions.

astro-ph.CO

Secular Equilibrium Assessment in a $\mathrm{CaWO}_4$ Target Crystal from the Dark Matter Experiment CRESST using Bayesian Likelihood Normalisation

CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-based normalisation results using a recently developed spectral template normalisation method based on Bayesian likelihood. We find deviations from SE; further investigations are necessary to determine their origin.

physics.ins-det

Towards an automated data cleaning with deep learning in CRESST

The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. With a data set of over one million labeled records from 68 detectors, recorded between 2013 and 2019 by CRESST, we test the capability of four commonly used neural network architectures to learn the data cleaning task. Our best performing model achieves a balanced accuracy of 0.932 on our test set. We show on an exemplary detector that about half of the wrongly predicted events are in fact wrongly labeled events, and a large share of the remaining ones have a context-dependent ground truth. We furthermore evaluate the recall and selectivity of our classifiers with simulated data. The results confirm that the trained classifiers are well suited for the data cleaning task.

physics.ins-det

Latest observations on the low energy excess in CRESST-III

The CRESST experiment observes an unexplained excess of events at low energies. In the current CRESST-III data-taking campaign we are operating detector modules with different designs to narrow down the possible explanations. In this work, we show first observations of the ongoing measurement, focusing on the comparison of time, energy and temperature dependence of the excess in several detectors. These exclude dark matter, radioactive backgrounds and intrinsic sources related to the crystal bulk as a major contribution.

astro-ph.CO

Testing spin-dependent dark matter interactions with lithium aluminate targets in CRESST-III

In the past decades, numerous experiments have emerged to unveil the nature of dark matter, one of the most discussed open questions in modern particle physics. Among them, the CRESST experiment, located at the Laboratori Nazionali del Gran Sasso, operates scintillating crystals as cryogenic phonon detectors. In this work, we present first results from the operation of two detector modules which both have 10.46 g LiAlO$_2$ targets in CRESST-III. The lithium contents in the crystal are $^6$Li, with an odd number of protons and neutrons, and $^7$Li, with an odd number of protons. By considering both isotopes of lithium and $^{27}$Al, we set the currently strongest cross section upper limits on spin-dependent interaction of dark matter with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$.

astro-ph.CO

$α$-event Characterization and Rejection in Point-Contact HPGe Detectors

P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the MAJORANA DEMONSTRATOR experiment, a search for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. $α$ decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $α$ identification, reliably identifying $α$ background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $α$ events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $0νββ$ region of interest window by an order of magnitude in the MAJORANA DEMONSTRATOR, and will be used in the upcoming LEGEND-200 experiment.

physics.ins-det

Probing spin-dependent dark matter interactions with $^6$Li

CRESST is one of the most prominent direct detection experiments for dark matter particles with sub-GeV/c$^2$ mass. One of the advantages of the CRESST experiment is the possibility to include a large variety of nuclides in the target material used to probe dark matter interactions. In this work, we discuss in particular the interactions of dark matter particles with protons and neutrons of $^{6}$Li. This is now possible thanks to new calculations on nuclear matrix elements of this specific isotope of Li. To show the potential of using this particular nuclide for probing dark matter interactions, we used the data collected previously by a CRESST prototype based on LiAlO$_2$ and operated in an above ground test-facility at Max-Planck-Institut für Physik in Munich, Germany. In particular, the inclusion of $^{6}$Li in the limit calculation drastically improves the result obtained for spin-dependent interactions with neutrons in the whole mass range. The improvement is significant, greater than two order of magnitude for dark matter masses below 1 GeV/c$^2$, compared to the limit previously published with the same data.

physics.ins-det

Surface characterization of p-type point contact germanium detectors

P-type point contact (PPC) germanium detectors are used in rare event and low-background searches, including neutrinoless double beta (0vbb) decay, low-energy nuclear recoils, and coherent elastic neutrino-nucleus scattering. The detectors feature an excellent energy resolution, low detection thresholds down to the sub-keV range, and enhanced background rejection capabilities. However, due to their large passivated surface, separating the signal readout contact from the bias voltage electrode, PPC detectors are susceptible to surface effects such as charge build-up. A profound understanding of their response to surface events is essential. In this work, the response of a PPC detector to alpha and beta particles hitting the passivated surface was investigated in a multi-purpose scanning test stand. It is shown that the passivated surface can accumulate charges resulting in a radial-dependent degradation of the observed event energy. In addition, it is demonstrated that the pulse shapes of surface alpha events show characteristic features which can be used to discriminate against these events.

physics.ins-det

Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on spin-dependent dark matter interactions with ordinary matter

In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut für Kristallzüchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50 GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments.

physics.ins-det

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay, is a ton-scale experimental program to search for neutrinoless double beta ($0νββ$) decay in the isotope $^{76}$Ge with an unprecedented sensitivity. Building on the success of the low-background $^{76}$Ge-based GERDA and MAJORANA DEMONSTRATOR experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond $10^{28}\,$yr on the decay half-life with approximately $10\,\text{t}\cdot\text{yr}$ of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

physics.ins-det

Description of CRESST-III Data

In CRESST-III, 10 cryogenic detector modules optimized for low energy thresholds were operated for almost two years (May 2016 - February 2018). Together with this document we are publishing data from the best performing detector module which has a nuclear recoil threshold of 30.1eV. With this data-set we were able to set limits on the cross-section for spin-dependent and spin-independent elastic scattering of dark matter particles off nuclei at dark matter masses down to 160MeV/c$^2$. We publish the energies of all events after data selection as well as of all events within the acceptance region for dark-matter searches. In this document we describe how to use these data sets.

astro-ph.CO