Searcharxiv⌕ Search

arXiv subjects

M. Woods

Publications and source records attributed to M. Woods.

32 records · Page 2Linked to original sources

Cavity BPM System Tests for the ILC Spectrometer

The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of $10^{-4}$ or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 hours for a $1\m$ long BPM triplet. We find micron-level stability over 1 hour for 3 BPM stations distributed over a $30\m$ long baseline. The understanding of the behaviour and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.

physics.ins-det↗

The role of polarized positrons and electrons in revealing fundamental interactions at the Linear Collider

The proposed International Linear Collider (ILC) is well-suited for discovering physics beyond the Standard Model and for precisely unraveling the structure of the underlying physics. The physics return can be maximized by the use of polarized beams. This report shows the paramount role of polarized beams and summarizes the benefits obtained from polarizing the positron beam, as well as the electron beam. The physics case for this option is illustrated explicitly by analyzing reference reactions in different physics scenarios. The results show that positron polarization, combined with the clean experimental environment provided by the linear collider, allows to improve strongly the potential of searches for new particles and the identification of their dynamics, which opens the road to resolve shortcomings of the Standard Model. The report also presents an overview of possible designs for polarizing both beams at the ILC, as well as for measuring their polarization.

hep-ph↗

A Test Facility for the International Linear Collider at SLAC End Station A, for Prototypes of Beam Delivery and IR Components

The SLAC Linac can deliver damped bunches with ILC parameters for bunch charge and bunch length to End Station A. A 10Hz beam at 28.5 GeV energy can be delivered there, parasitic with PEP-II operation. We plan to use this facility to test prototype components of the Beam Delivery System and Interaction Region. We discuss our plans for this ILC Test Facility and preparations for carrying out experiments related to collimator wakefields and energy spectrometers. We also plan an interaction region mockup to investigate effects from backgrounds and beam-induced electromagnetic interference.

physics.ins-det↗

A New Measurement of the Weak Mixing Angle

The E158 experiment at SLAC has made the first measurement of parity violation in electron-electron (Moller) scattering. We report a preliminary result using 50% of the accumulated data sample for the right-left parity-violating cross-section asymmetry (APV) in the elastic scattering of 45 and 48 GeV polarized electron beams with unpolarized electrons in a liquid hydrogen target. We find APV = (-160 +- 21 (stat.) +- 17 (syst.)) parts per billion, with a significance of 6.3sigma for observing parity violation. In the context of the Standard Model, this yields a measurement of the weak mixing angle, sin^2(thetaW-MSBAR)(Q^2 = 0.026 GeV^2) = 0.2379 +- 0.0016 (stat.) +- 0.0013 (syst.). We also present preliminary results for the first observation of a single-spin transverse asymmetry in Moller scattering.

hep-ex↗

Luminosity, Energy and Polarization Studies for the Linear Collider: Comparing e+e- and e-e- for NLC and TESLA

We present results from luminosity, energy and polarization studies at a future Linear Collider. We compare e+e- and e-e- modes of operation and consider both NLC and TESLA beam parameter specifications at a center-of-mass energy of 500 GeV. Realistic colliding beam distributions are used, which include dynamic effects of the beam transport from the Damping Rings to the Interaction Point. Beam-beam deflections scans and their impact for beam-based feedbacks are considered. A transverse kink instability is studied, including its impact on determining the luminosity-weighted center-of-mass energy. Polarimetry in the extraction line from the IP is presented, including results on beam distributions at the Compton IP and at the Compton detector.

physics.acc-ph↗

SLAC's Polarized Electron Source Laser System and Minimization of Electron Beam Helicity Correlations for the E-158 Parity Violation Experiment

SLAC E-158 is an experiment designed to make the first measurement of parity violation in Moller scattering. E-158 will measure the right-left cross-section asymmetry, A_LR^Moller, in the elastic scattering of a 45-GeV polarized electron beam off unpolarized electrons in a liquid hydrogen target. E-158 plans to measure the expected Standard Model asymmetry of ~10^-7 to an accuracy of better than 10^-8. To make this measurement, the polarized electron source requires for operation an intense circularly polarized laser beam and the ability to quickly switch between right- and left-helicity polarization states with minimal right-left helicity-correlated asymmetries in the resulting beam parameters (intensity, position, angle, spot size, and energy), ^beam A_LR's. This laser beam is produced by a unique SLAC-designed flashlamp-pumped Ti:Sapphire laser and is propagated through a carefully designed set of polarization optics. We analyze the transport of nearly circularly polarized light through the optical system and identify several mechanisms that generate ^beam A_LR's. We show that the dominant effects depend linearly on particular polarization phase shifts in the optical system. We present the laser system design and a discussion of the suppression and control of ^beam A_LR's. We also present results on beam performance from engineering and physics runs for E-158.

physics.acc-ph↗

The Next Linear Collider Extraction Line Design

The two main functions of the NLC extraction line include: 1) transmission of the outgoing disrupted beam and secondary particles to the dump with minimal losses; and 2) beam diagnostics and control. In this report, we describe the extraction line optics, present the results of tracking studies, and discuss the extraction line instrumentation.

physics.acc-ph↗

Experimental Issues for Precision Electroweak Physics at a High-Luminosity Z Factory

We discuss the ultimate precision for ALR, and therefore for the weak mixing angle, at a high-luminosity Linear Collider. Drawing on our experience at the SLC, and considering various machine parameter sets for the NLC and for TESLA, it emerges that a compromise between peak luminosity and precision will be a likely outcome. This arises due to the severe requirements on the uncertainty in the luminosity weighted collision energy (Ecm). We consider the cases with and without a polarized positron beam.

hep-ex↗

Polarimetry at a Future Linear Collider - How Precise?

At a future linear collider, a polarized electron beam will play an important role in interpreting new physics signals. Backgrounds to a new physics reaction can be reduced by choice of the electron polarization state. The origin of a new physics reaction can be clarified by measuring its polarization-dependence. This paper examines some options for polarimetry with an emphasis on physics issues that motivate how precise the polarization determination needs to be. In addition to Compton polarimetry, the possibility of using Standard Model asymmetries, such as the asymmetry in forward W-pairs, is considered as a possible polarimeter. Both e+e- and e-e- collider modes are considered.

hep-ex↗

Electroweak Results from the SLD Experiment

We present an overview of the electroweak physics program of the SLD experiment at the Stanford Linear Accelerator Center (SLAC). A data sample of 550K Z0 decays has been collected. This experiment utilizes a highly polarized electron beam, a small interaction volume, and a very precise pixel vertex detector. We present a preliminary result for the weak mixing angle, sin2(thetaw)=0.23110 +- 0.00029. We also present a preliminary result for the parity violating parameter, A_b = 0.898 +- 0.029. These measurements are used to test for physics beyond the Standard Model.

hep-ex↗

Compton Polarimetry at a TEV Collider

An electron beam polarization of 80% or greater will be a key feature of a 1 TeV Linear Collider. Accurate measurements of the beam polarization will therefore be needed. We discuss design considerations and capabilities for a Compton-scattering polarimeter located in the extraction line from the Interaction Point. Polarization measurements with 1% accuracy taken parasitic to collision data look feasible, but detailed simulations are needed. Polarimeter design issues are similar for both electron-positron and electron-electron collider modes, though beam disruption creates more difficulties for the electron-electron mode.

hep-ex↗

The polarized electron beam for the SLAC Linear Collider

The SLAC Linear Collider has been colliding a polarized electron beam with an unpolarized positron beam at the Z^0 resonance for the SLD experiment since 1992. An electron beam polarization of close to 80% has been achieved for the experiment at luminosities up to 8x10^29 cm^-2 s^-1. This is the world's first and only linear collider, and is a successful prototype for the next generation of high energy electron linear colliders. This paper discusses polarized beam operation for the SLC, and includes aspects of the polarized source, spin transport and polarimetry. Presented at the 12th International Symposium on High Energy Spin Physics held at Amsterdam, The Netherlands September 10-14, 1996.

hep-ex↗

The scanning Compton polarimeter for the SLD experiment

For the 1994/95 run of the SLD experiment at SLAC, a Compton polarimeter measured the luminosity-weighted electron beam polarization to be (77.2 +- 0.5)%. This excellent accuracy is achieved by measuring the rate asymmetry of Compton-scattered electrons near the kinematic endpoint. The polarimeter takes data continuously while the electron and positron beams are in collision and achieves a statistical precision of better than 1% in a three minute run. To calibrate the polarimeter and demonstrate its accuracy, many scans are frequently done. These include scans of the laser polarization, the detector position with respect to the kinematic edge, and the laser power. Presented at the Workshop on High Energy Polarimeters at NIKHEF, Amsterdam, The Netherlands on September 9, 1996.

hep-ex↗

Observation of Target Electron Momentum Effects in Single-Arm Møller Polarimetry

In 1992, L.G. Levchuk noted that the asymmetries measured in Møller scattering polarimeters could be significantly affected by the intrinsic momenta of the target electrons. This effect is largest in devices with very small acceptance or very high resolution in laboratory scattering angle. We use a high resolution polarimeter in the linac of the polarized SLAC Linear Collider to study this effect. We observe that the inclusion of the effect alters the measured beam polarization by -14% of itself and produces a result that is consistent with measurements from a Compton polarimeter. Additionally, the inclusion of the effect is necessary to correctly simulate the observed shape of the two-body elastic scattering peak.

hep-ex↗