SearcharxivSearch

arXiv subjects

M. Y. Pac

Publications and source records attributed to M. Y. Pac.

At least 19 recordsLinked to original sources

First results from the search for an excess of $\bar{\nu}_{e}$ events in JSNS$^2$

The JSNS$^2$ (J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source) experiment at the Material and Life Science Facility (MLF) of J-PARC is designed to directly test an excess on $\bar{\nu}_{e}$ events which was indicated by LSND (Liquid Scintillator Neutrino Detector). The combination of a short-pulsed proton beam and a gadolinium-loaded liquid scintillator provides an excellent signal-to-noise ratio. In this article, we report the first results of a direct test based on data collected in 2022. After applying all event selection criteria, two events are observed, consistent with the expected background of 2.3$\pm$0.4 events. No excess of $\bar{\nu}_e$ events are seen in this report, however the expected number of events due to LSND anomaly is 1.1$\pm$0.5, thus this result is not yet conclusive. Data taking has been ongoing since 2021 and will continue in future runs. In addition, a new far detector has recently been constructed for the second phase experiment, JSNS$^2$-II, marking an important milestone toward forthcoming measurements.

hep-ex

PMT calibration for the JSNS2-II far detector with an embedded LED system

The JSNS2-II (the second phase of JSNS2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. This experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. The properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector, such as gain, its dependence of supplied High Voltage (HV), and Peak-to-Valley (PV) were calibrated. To achieve a good energy resolution for physics events, up to 10% of the relative gain adjustment is required for all functioning PMTs. This will be achieved using the measured HV curves and the LED calibration. The Peak-to-Valley (PV) ratio values are the similar to those from the production company, which distinguish the single photo-electron signal from the pedestal. Additionally, the precision of PMT signal timing is measured to be 2.1 ns, meeting the event reconstruction requirement of 10 ns.

physics.ins-det

Muon tagging with Flash ADC waveform baselines

This manuscript describes an innovative method to tag the muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS1 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. This experiment is designed for the search for sterile neutrinos, and a muon tagging is an essential key component for the background rejection since the detector of the experiment is located over-ground, where is the 3rd floor of the J-PARC Material and Life experimental facility (MLF). Especially, stopping muons inside the detector create the Michel electrons, and they are important background to be rejected. Utilizing this innovative method, more than 99.8% of Michel electrons can be rejected even without a detector veto region. This technique can be employed for any experiments which uses the similar detector configurations.

physics.ins-det

Measurement of reactor antineutrino oscillation amplitude and frequency using 3800 days of complete data sample of the RENO experiment

We report an updated neutrino mixing angle of $\theta_{13}$ obtained from a complete data sample of the RENO experiment. The experiment has measured the amplitude and frequency of reactor anti-electron-neutrinos ($\bar{\nu}_{e}$) oscillations at the Hanbit nuclear power plant, Younggwang, Korea, since August 2011. As of March 2023, the data acquisition was completed after a total of 3800 live days of detector operation. The observed candidates via inverse beta decay (IBD) are 1,211,995 (144,667) in the near (far) detector. Based on an observed energy-dependent reactor neutrino disappearance, neutrino oscillation parameters of $\theta_{13}$ and $\lvert\Delta m_{ee}^2\rvert$ are precisely determined as $\sin^{2}2\theta_{13}=0.0920_{-0.0042}^{+0.0044}(\text{stat.})_{-0.0041}^{+0.0041}(\text{syst.})$ and $\lvert\Delta m_{ee}^2\rvert=\left[2.57_{-0.11}^{+0.10}(\text{stat.})_{-0.05}^{+0.05}(\text{syst.})\right]\times10^{-3}~\text{eV}^{2}$. Compared to the previous RENO results published in Ref.~\cite{PhysRevLett.121.201801}, the precision is improved from 7.5\% to 6.4\% for $\sin^{2}2\theta_{13}$ and from 5.2\% to 4.5\% for $\lvert\Delta m_{ee}^2\rvert$. The statistical error of the measurement has reached our goal and is hardly improved with additional data-taking.

hep-ex

The first JSNS$^2$ measurement of electron neutrino flux using $^{12}C(\nu_{e},e^{-}) ^{12}N_{g.s.}$ reaction

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment searching for sterile neutrinos through the observation of $\bar{\nu}_{\mu} \rightarrow \bar{\nu}_e$ appearance oscillations, using neutrinos produced by muon decay-at-rest. A key aspect of the experiment involves accurately understanding the neutrino flux and the quantities of pions and muons, which are progenitors of (anti-)neutrinos, given that their production rates have yet to be measured. We present the first electron-neutrino flux measurement using $^{12}\mathrm{C}(\nu_{e},e^{-}) ^{12}\mathrm{N}_{g.s.}$ reaction in JSNS$^2$, yielding a flux of (6.7 $\pm$ 1.6 (stat.) $\pm$ 1.7 (syst.)) $\times$ 10$^{-9}$ cm$^{-2}$ proton$^{-1}$ at the JSNS$^2$ detector location, located at 24 meters distance from the mercury target. This flux measurement is consistent with predictions from simulations based on hadron models.

hep-ex

First Measurement of Missing Energy Due to Nuclear Effects in Monoenergetic Neutrino Charged Current Interactions

We present the first measurement of the missing energy due to nuclear effects in monoenergetic, muon neutrino charged-current interactions on carbon, originating from $K^+ \rightarrow \mu^+ \nu_\mu$ decay at rest ($E_{\nu_\mu}=235.5$ MeV), performed with the J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source liquid scintillator based experiment. Toward characterizing the neutrino interaction, ostensibly $\nu_\mu n \rightarrow \mu^- p$ or $\nu_\mu$$^{12}\mathrm{C}$ $\rightarrow \mu^-$$^{12}\mathrm{N}$, we define the missing energy as the energy transferred to the nucleus ($\omega$) minus the kinetic energy of the outgoing proton(s), $E_{m} \equiv\omega-\sum T_p$, and relate this to visible energy in the detector, $E_{m}=E_{\nu_\mu} (235.5 \mathrm{MeV})-m_\mu (105.7 \mathrm{MeV}) + [m_n-m_p (1.3 \mathrm{MeV})] - E_{\mathrm{vis}}$. The missing energy, which is naively expected to be zero in the absence of nuclear effects (e.g. nucleon separation energy, Fermi momenta, and final-state interactions), is uniquely sensitive to many aspects of the interaction, and has previously been inaccessible with neutrinos. The shape-only, differential cross section measurement reported, based on a $(77\pm3)$% pure double-coincidence kaon decay-at-rest signal (621 total events), provides detailed insight into neutrino-nucleus interactions, allowing even the nuclear orbital shell of the struck nucleon to be inferred. The measurement provides an important benchmark for models and event generators at hundreds of MeV neutrino energies, characterized by the difficult-to-model transition region between neutrino-nucleus and neutrino-nucleon scattering, and relevant for applications in nuclear physics, neutrino oscillation measurements,and Type-II supernova studies.

hep-ex

Study on the accidental background of the JSNS$^2$ experiment

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment which searches for sterile neutrinos via the observation of $\barν_μ \to \barν_{e}$ appearance oscillations using muon decay-at-rest neutrinos. The data taking of JSNS$^2$ have been performed from 2021. In this manuscript, a study of the accidental background is presented. The rate of the accidental background is (9.29$\pm 0.39) \times 10^{-8}$ / spill with 0.75 MW beam power and comparable to the number of searching signals.

hep-ex

Evaluation of the performance of the event reconstruction algorithms in the JSNS$^2$ experiment using a $^{252}$Cf calibration source

JSNS$^2$ searches for short baseline neutrino oscillations with a baseline of 24~meters and a target of 17~tonnes of the Gd-loaded liquid scintillator. The correct algorithm on the event reconstruction of events, which determines the position and energy of neutrino interactions in the detector, are essential for the physics analysis of the data from the experiment. Therefore, the performance of the event reconstruction is carefully checked with calibrations using $^{252}$Cf source. This manuscript describes the methodology and the performance of the event reconstruction.

hep-ex

Pulse Shape Discrimination in JSNS$^2$

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\bar{\nu}_{\mu} \rightarrow \bar{\nu}_e$ appearance oscillations using neutrinos with muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS$^2$ detector is located above ground, on the third floor of the building. We have achieved 95$\%$ rejection of neutron events while keeping 90$\%$ of signal, electron-like events using a data driven likelihood method.

physics.ins-det

The acrylic vessel for JSNS$^{2}$-II neutrino target

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS$^{2}$-II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. The specifications, design, and measured properties of the acrylic vessel are described.

hep-ex

In-Situ Measurement of Relative Attenuation Length of Gadolinium-Loaded Liquid Scintillator Using Source Data at RENO Experiment

We present in situ measurements of the relative attenuation length of the gadolinium loaded liquid scintillator in the RENO (Reactor Experiment Neutrino Oscillation) detectors using radioactive source calibration data. We observed a steady decrease in the attenuation length of the Gd-LS in the RENO detectors by 50% in about four years since the commissioning of the detectors.

physics.ins-det

Search for sterile neutrino oscillation using RENO and NEOS data

We present a reactor model independent search for sterile neutrino oscillation using 2\,509\,days of RENO near detector data and 180 days of NEOS data. The reactor related systematic uncertainties are significantly suppressed as both detectors are located at the same reactor complex of Hanbit Nuclear Power Plant. The search is performed by electron antineutrino\,($\overlineν_e$) disappearance between six reactors and two detectors with baselines of 294\,m\,(RENO) and 24\,m\,(NEOS). A spectral comparison of the NEOS prompt-energy spectrum with a no-oscillation prediction from the RENO measurement can explore reactor $\overlineν_e$ oscillations to sterile neutrino. Based on the comparison, we obtain a 95\% C.L. excluded region of $0.1<|Δm_{41}^2|<7$\,eV$^2$. We also obtain a 68\% C.L. allowed region with the best fit of $|Δm_{41}^2|=2.41\,\pm\,0.03\,$\,eV$^2$ and $\sin^2 2θ_{14}$=0.08$\,\pm\,$0.03 with a p-value of 8.2\%. Comparisons of obtained reactor antineutrino spectra at reactor sources are made among RENO, NEOS, and Daya Bay to find a possible spectral variation.

hep-ex

Measurement of cosmogenic $^9$Li and $^8$He production rates at RENO

We report the measured production rates of unstable isotopes $^9$Li and $^8$He produced by cosmic muon spallation on $^{12}$C using two identical detectors of the RENO experiment. Their beta-decays accompanied by a neutron make a significant contribution to backgrounds of reactor antineutrino events in precise determination of the smallest neutrino mixing angle. The mean muon energy of its near (far) detector with an overburden of 120 (450) m.w.e. is estimated as 33.1 +- 2.3 (73.6 +- 4.4) GeV. Based on roughly 3100 days of data, the cosmogenic production rate of $^9$Li ($^8$He) isotope is measured to be 44.2 +- 3.1 (10.6 +- 7.4) per day at near detector and 10.0 +- 1.1 (2.1 +- 1.5) per day at far detector. This corresponds to yields of $^9$Li ($^8$He), 4.80 +- 0.36 (1.15 +- 0.81) and 9.9 +- 1.1 (2.1 +- 1.5) at near and far detectors, respectively, in a unit of 10$^{-8}$ $μ^{-1}$ g${^-1}$ cm${^2}$. Combining the measured $^9$Li yields with other available underground measurements, an excellent power-law relationship of the yield with respect to the mean muon energy is found to have an exponent of $α$ = 0.75 +- 0.05.

nucl-ex

Characterization of the correlated background for a sterile neutrino search using the first dataset of the JSNS$^2$ experiment

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\barν_μ \to \barν_{e}$ appearance oscillations using muon decay-at-rest neutrinos. Before dedicated data taking in the first-half of 2021, we performed a commissioning run for 10 days in June 2020. Using the data obtained in this commissioning run, in this paper, we present an estimate of the correlated background which imitates the $\barν_{e}$ signal in a sterile neutrino search. In addition, in order to demonstrate future prospects of the JSNS$^2$ experiment, possible pulse shape discrimination improvements towards reducing cosmic ray induced fast neutron background are described.

hep-ex

Measurement of Reactor Antineutrino Flux and Spectrum at RENO

The RENO experiment reports measured flux and energy spectrum of reactor electron antineutrinos\,($\overlineν_e$) from the six reactors at Hanbit Nuclear Power Plant. The measurements use 966\,094\,(116\,111)\,$\overlineν_e$ candidate events with a background fraction of 2.39\%\,(5.13\%), acquired in the near\,(far) detector, from August 2011 to March 2020. The inverse beta decay (IBD) yield is measured as (5.852$\,\pm\,$0.124$) \times 10^{-43}$\,cm$^2$/fission, corresponding to 0.941\,$\pm$ 0.019 of the prediction by the Huber and Mueller (HM) model. A reactor $\overlineν_e$ spectrum is obtained by unfolding a measured IBD prompt spectrum. The obtained neutrino spectrum shows a clear excess around 6\,MeV relative to the HM prediction. The obtained reactor $\overlineν_e$ spectrum will be useful for understanding unknown neutrino properties and reactor models. The observed discrepancies suggest the next round of precision measurements and modification of the current reactor $\overlineν_e$ models.

hep-ex

The JSNS^2 Detector

The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS^2 detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this paper, we describe the JSNS^2 detector design, construction, and operation.

physics.ins-det

Slow control and monitoring system at the JSNS$^{2}$

The JSNS$^2$ experiment is aimed to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1\% gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage (HV) of the photomultiplier tubes (PMTs), the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in June 2020. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

physics.ins-det

Proposal: JSNS$^2$-II

This article describes the goal and expected sensitivity of the JSNS$^2$-II experiment at J-PARC Materials and Life Science Experimental Facility (MLF). The JSNS$^2$-II experiment is the second phase of the JSNS$^2$ experiment (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) with two detectors which are located in 24 m (an existing detector) and 48 m (new one) baselines to improve the sensitivity of the search for sterile neutrinos, especially in the low $Δm^2$ region, which has been indicated by the global fit of the appearance mode. The new second detector has a similar structure as the existing JSNS$^2$ detector, which is already working. To compensate for the reduction of the neutrino flux due to the distance from the mercury target, the target mass of the Gd-loaded liquid scintillator which is the Linear AlkylBenzene (LAB) based liquid scintillator inside the acrylic vessel is 35 tons. To keep the same photo-coverage of the detector as the first detector, we will surround the acrylic vessel with 240 PMTs. With this experimental setup and 5 years (times 1 MW beam power) exposure, the sensitivity of the JSNS$^2$-II is significantly improved compared to the current JSNS$^2$, especially in the low $Δm^2$ oscillation parameter region. The JSNS$^2$-II can also confirm or refute the most of the oscillation parameters' space preferred by the previous experiments with 3 sigma C.L.. Considering these situations and world wide status of the sterile neutrino searches, we are eager to start the data taking with the two detector configuration from 2023. The fund to build the second detector was already secured.

hep-ex