SearcharxivSearch

arXiv subjects

M. Zhao

Publications and source records attributed to M. Zhao.

At least 19 recordsLinked to original sources

Initial Performance of the TUCAN Magnetically Shielded Room

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has commissioned a large magnetically shielded room to be used for measuring the neutron electric dipole moment (nEDM) to a precision of $10^{-27}~e\mathrm{cm}$. The room is composed of five layers of MuMetal and one layer of copper and sits within the $\lesssim 370~\mu\mathrm{T}$ ambient field produced by the TRIUMF cyclotron. Within this environment, the quasi-static shielding factor was measured to be $3.25(2) \times 10^4$ at $0.01~\mathrm{Hz}$ with an external peak-to-peak perturbation of $2~\mu\mathrm{T}$. Without the large ambient cyclotron field, the shielding factor improves to $3.75(4)\times 10^4$ at the same perturbation amplitude and frequency. After idealization in the cyclotron field, the residual field at the room center was $B = 1.8(2)~\mathrm{nT}$ and the vertical first-order gradient across the central 1~m$^3$ ($dB_{\mathrm{z}}/dz$) was $-279(64)~\mathrm{pT/m}$. With additional improvement to the idealization, and with active compensation, we expect the room to be adequate for a $10^{-27}~e\mathrm{cm}$ nEDM search.

physics.ins-det

In situ magnetic-field stabilization for quantum-gas experiments

We demonstrate a minimally-destructive in situ technique for measuring and stabilizing slowly-drifting magnetic fields in ultracold-atom experiments. While conventional magnetic-field sensors such as Hall, giant magnetoresistive, or fluxgate-based devices are broadly used, their accuracy, precision and dynamic range can be limited. In addition, these sensors are typically positioned at least several centimeters away from the in-vacuum atomic system, as their operation creates perturbing magnetic fields, and their placement is limited by geometric constraints imposed by the vacuum system. We overcome these issues by using the atomic system itself as a built-in magnetometer. To that end, we employ a pair of weak measurements to determine the Zeeman splitting -- and thereby the magnetic field -- of a magnetically sensitive atomic transition. We provide closed-form expressions quantifying the trade-offs between measurement noise, dynamic range, and atom loss. This procedure is demonstrated with ultracold Rb-87, weakly measured using partial-transfer absorption imaging. We then incorporate a Kalman filter to stabilize the magnetic field; this eliminated long-term drift in the ambient field (as high as ~70 nT/hr) in exchange for a modest increase in shot-to-shot variability from 1.8(2) nT to 2.0(2) nT.

physics.atom-ph

Ultracold Neutron Guide-Coating Facility at U.Winnipeg

We report the construction and commissioning of a new ultracold neutron (UCN) guide-coating facility at the University of Winnipeg. The facility employs pulsed laser deposition (PLD) to produce diamond-like carbon (DLC) coatings on cylindrical UCN guides up to 1 m in length with a 200 mm outer diameter. DLC is a promising material for UCN transport and storage due to its high real component of the optical potential, low neutron absorption cross section, and low depolarization probabilities. First coating attempts on a full length aluminum UCN guide and matching blank flange were successfully coated with a carbon film with density of 2.3 g/cm$^3$, corresponding to optical potentials of 200 neV, as measured by X-ray reflectometry (XRR). Coating thicknesses were measured to be 90 nm for the UCN guide and 180 nm for the flange with no evidence of delamination. The implementation of a plasma plume collimator and plasma feed back control via a time of flight in vacuum ion probe produced a film with an XRR measured density of 2.8 g/cm$^3$, corresponding to an optical potential of 240 neV. This 80 nm thick film had poor adhesion to the aluminum tube substrate. These results establish a baseline for the coating facility. Ongoing and future work focuses on improving the diamond content of films and adhesion through plasma plume collimation, TOF ion probe feed back, and pre/post treatment methods with the goal of providing high quality DLC UCN guides for the TUCAN experiment at TRIUMF.

physics.ins-det

Initial results of the TRIUMF ultracold advanced neutron source

We report the first results on ultracold neutron production from a new spallation-driven superfluid $^4$He (He-II) source at TRIUMF, which is being prepared for a new, precise measurement of the neutron electric dipole moment. A total of $(9.3 \pm 0.8)\times 10^{5}$ ultracold neutrons were observed at a proton beam current of \SI{37}{\uA}, when the target was irradiated for a period of \SI{60}{\s}. The results are in fair agreement with expectations based on a detailed simulation of neutron transport and ultracold neutron source cryogenics. There is some indication that the new source might not be as limited by the conduction of heat through the He-II as originally expected. The results indicate that the source is likely to make its ultimate production goals, once the liquid deuterium cold moderator system is completed, with the expectation that $5.7\times 10^7$~UCNs would be detected in the same experiment with full liquid levels. This would, for example, correspond to delivery of $1.4\times 10^6$~UCNs delivered to each of two nEDM measurement cells, and a statistical uncertainty of $1\times 10^{-27}~e$cm on the neutron EDM in 280 days of running.

nucl-ex

Neutron EDM Experiment with an Advanced Ultracold Neutron Source at TRIUMF

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has been developing a high-intensity ultracold neutron (UCN) source aimed at searching for the neutron electric dipole moment (EDM) with a sensitivity goal of $10^{-27}\ e{\rm cm}$. This article reports on recent progress in commissioning of the UCN source and in the development of the neutron EDM spectrometer. In its final configuration, the accelerator-driven super-thermal UCN source will enable a neutron EDM experiment with two orders of magnitude improved statistics compared to the current best experiment. Substantial progress in 2024 allowed the collaboration to operate the complete source system, with the exception of the liquid deuterium cold moderator, resulting in the first production of UCNs. The status of the EDM spectrometer is also presented, with emphasis on UCN handling components and magnetic subsystems relevant to field control, shielding, and magnetometry.

physics.ins-det

Cryogenic systems for the TUCAN EDM experiment

The TUCAN (TRIUMF UltraCold Advanced Neutron) Collaboration is completing a new ultracold neutron (UCN) source. The UCN source will deliver UCNs to a neutron electric dipole moment (EDM) experiment. The EDM experiment is projected to be capable of an uncertainty of $1\times 10^{-27}~e$cm, competitive with other planned projects, and a factor of ten more precise than the present world's best. The TUCAN source is based on a UCN production volume of superfluid helium (He-II), held at 1~K, and coupled to a proton-driven spallation target. The production rate in the source is expected to be in excess of $10^7$~UCN/s; since UCN losses can be small in superfluid helium, this should allow us to build up a large number of UCNs. The spallation-driven superfluid helium technology is the principal aspect making the TUCAN project unique. The superfluid production volume was recently cooled, for the first time, and successfully filled with superfluid helium. The design principles of the UCN source are described, along with some of the challenging cryogenic milestones that were recently passed.

physics.ins-det

Water-based Quantum Dots Liquid Scintillator for Particle Physics

Liquid scintillators are typically composed from organic compounds dissolved in organic solvents. However, usage of such material is often restricted due to fire safety and environmental reasons. Because of this, R\&D of water-based liquid scintillators is of extreme relevance; yet, no such scintillators have been made commercially available as yet. Here, we investigate an alternative, water-based quantum dots liquid scintillator. Pre-determined and controllable optical properties of the quantum dots, as well as the existence of large libraries of established protocols for their dispersion in aqueous solutions, make them an attractive option for nuclear and particle physics applications. We characterize the optical properties of water-based quantum dots liquid scintillator and find that most of its optical properties are preserved upon quantum dots' phase transfer into water, through the addition of an oleic acid hydrophilic layer. Using the developed scintillator, the time and charge responses from atmospheric muons are measured, highlighting the practical viability of water-based quantum dots liquid scintillators for nuclear and particle physics, special interest on neutrino physics.

physics.ins-det

Controlling fingering instabilities in Hele-Shaw flows in the presence of wetting film effects

In this paper, the interfacial motion between two immiscible viscous fluids in the confined geometry of a Hele-Shaw cell is studied. We consider the influence of a thin wetting film trailing behind the displaced fluid, which dynamically affects the pressure drop at the fluid-fluid interface by introducing a nonlinear dependence on the interfacial velocity. In this framework, two cases of interest are analyzed: The injection-driven flow (expanding evolution), and the lifting plate flow (shrinking evolution). In particular, we investigate the possibility of controlling the development of fingering instabilities in these two different Hele-Shaw setups when wetting effects are taken into account. By employing linear stability theory, we find the proper time-dependent injection rate $Q(t)$ and the time-dependent lifting speed ${\dot b}(t)$ required to control the number of emerging fingers during the expanding and shrinking evolution, respectively. Our results indicate that the consideration of wetting leads to an increase in the magnitude of $Q(t)$ [and ${\dot b}(t)$] in comparison to the non-wetting strategy. Moreover, a spectrally accurate boundary integral approach is utilized to examine the validity and effectiveness of the controlling protocols at the fully nonlinear regime of the dynamics and confirms that the proposed injection and lifting schemes are feasible strategies to prescribe the morphologies of the resulting patterns in the presence of the wetting film.

physics.flu-dyn

Pattern formation of the three-layer Saffman-Taylor problem in a radial Hele-Shaw cell

The three-layer Saffman-Taylor problem introduces two coupled moving interfaces separating the three fluids. A very recent weakly nonlinear analysis of this problem in a radial Hele-Shaw cell setup has shown that the morphologies of the emerging fingering patterns strongly depend on the initial thickness of the intermediate layer connecting the two interfaces. Here we go beyond the weakly nonlinear regime and explore full nonlinear interfacial dynamics using a spectrally accurate boundary integral method. We quantify the nonlinear instability of both interfaces as the relevant physical parameters (e.g., viscosities and surface tensions) are varied and show that our nonlinear computations are in good agreement with the experimental observations and the weakly nonlinear analysis. Nonlinear simulations reveal that due to the existence of a second interface, the classical highly branched morphologies are replaced by less unstable structures in which finger tip-splitting and finger competition phenomena are evidently restrained as the initial annulus' thickness is reduced. In addition, these novels patterns develop fingers with a series of low-amplitude bumps at their tips, associated with the enhanced growth of high-frequency modes promoted by the increasing coupling strength of interfaces.

physics.flu-dyn

Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)

To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated with Novel Device Laboratory (NDL) of Beijing Normal University and they are now under detailed study. These detectors are tested with $5GeV$ electron beam at DESY. A SiPM detector is chosen as a reference detector to get the timing resolution of LGADs. The fluctuation of time difference between LGAD and SiPM is extracted by fitting with a Gaussian function. Constant fraction discriminator (CFD) method is used to mitigate the effect of time walk. The timing resolution of $41 \pm 1 ps$ and $63 \pm 1 ps$ are obtained for BV60 and BV170 respectively.

physics.ins-det

Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.

physics.ins-det

Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

physics.ins-det

The PROSPECT Reactor Antineutrino Experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT is a movable 4-ton antineutrino detector covering distances of 7m to 13m from the High Flux Isotope Reactor core. It will probe the best-fit point of the $\barν_e$ disappearance experiments at 4$σ$ in 1 year and the favored regions of the sterile neutrino parameter space at more than 3$σ$ in 3 years. PROSPECT will test the origin of spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly. This paper describes the design, construction, and commissioning of PROSPECT and reports first data characterizing the performance of the PROSPECT antineutrino detector.

physics.ins-det

Realization of a fractional period adiabatic superlattice

We propose and realize a deeply sub-wavelength optical lattice for ultracold neutral atoms using $N$ resonantly Raman-coupled internal degrees of freedom. Although counter-propagating lasers with wavelength $λ$ provided two-photon Raman coupling, the resultant lattice-period was $λ/2N$, an $N$-fold reduction as compared to the conventional $λ/2$ lattice period. We experimentally demonstrated this lattice built from the three $F=1$ Zeeman states of a $^{87}{\rm Rb}$ Bose-Einstein condensate, and generated a lattice with a $λ/6= 132\ {\rm nm}$ period from $λ=790 \ {\rm nm}$ lasers. Lastly, we show that adding an additional RF coupling field converts this lattice into a superlattice with $N$ wells uniformly spaced within the original $λ/2$ unit cell.

cond-mat.quant-gas

First search for short-baseline neutrino oscillations at HFIR with PROSPECT

This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of $^{235}$U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, consists of a segmented 4 ton $^6$Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 meter water equivalent overburden. Data collected during 33 live-days of reactor operation at a nominal power of 85 MW yields a detection of 25461 $\pm$ 283 (stat.) inverse beta decays. Observation of reactor antineutrinos can be achieved in PROSPECT at 5$σ$ statistical significance within two hours of on-surface reactor-on data-taking. A reactor-model independent analysis of the inverse beta decay prompt energy spectrum as a function of baseline constrains significant portions of the previously allowed sterile neutrino oscillation parameter space at 95% confidence level and disfavors the best fit of the Reactor Antineutrino Anomaly at 2.2$σ$ confidence level.

hep-ex

MOPSS I: Flat Optical Spectra for the Hot Jupiters WASP-4 b and WASP-52b

We present the first results from MOPSS, The Michigan Optical Planetary Spectra Survey, aimed at creating a database of optical planetary transmission spectra all observed, reduced, and analyzed with a uniform method for the benefit of enabling comparative exoplanet studies. We discuss our methods, and present results for our first two targets observed with the Magellan Baade 6.5m telescope, one transit of the Hot Jupiter WASP-4b and two transits of the Hot Saturn WASP-52b. Both targets present flat, featureless spectra, corresponding to the presence of aerosols. We find that the cloud decks must begin no lower than 10$^{-4}$ bar for both planets. For WASP-52b, we also consider the effects of star spots on the transmission spectrum, including unocculted spots and spots on the stellar limb influencing the light curve limb darkening parameters. We discuss the usefulness of this program in the coming James Webb Space Telescope era.

astro-ph.EP

Universal voltage scaling due to self-averaging of the quantum corrections in graphene

The differential conductance of graphene is shown to exhibit a zero-bias anomaly at low temperatures, arising from a suppression of the quantum corrections due to weak localization and electron interactions. A simple rescaling of these data, free of any adjustable parameters, shows that this anomaly exhibits a universal, temperature- ($T$) independent form. According to this, the differential conductance is approximately constant at small voltages ($V<k_BT/e$), while at larger voltages it increases logarithmically with the applied bias, reflecting a quenching of the quantum corrections. For theoretical insight into the origins of this behavior, we formulate a model for weak-localization in the presence of nonlinear transport. According to this, the voltage applied under nonequilibrium induces unavoidable dephasing, arising from a self-averaging of the diffusing electron waves responsible for transport. By establishing the manner in which the quantum corrections are suppressed in graphene, our study will be of broad relevance to the investigation of nonequilibrium transport in mesoscopic systems in general. This includes systems implemented from conventional metals and semiconductors, as well as those realized using other two-dimensional semiconductors and topological insulators.

cond-mat.mes-hall

Surgical task-space optimisation of the CYCLOPS robotic system

The CYCLOPS is a cable-driven parallel mechanism used for minimally invasive applications, with the ability to be customised to different surgical needs; allowing it to be made procedure- and patient-specific. For adequate optimisation, however, appropriate data on clinical constraints and task-space is required. Whereas the former can be provided through preoperative planning and imaging, the latter remains a problem, primarily for highly dexterous MIS systems. The current work focuses on the development of a task-space optimisation method for the CYCLOPS system and the development of a data collection method in a simulation environment for minimally invasive task-spaces. The same data collection method can be used for the development of other minimally invasive platforms. A case-study is used to illustrate the developed method for Endoscopic Submucosal Dissection (ESD). This paper shows that using this method, the system can be succesfully optimised for this application.

cs.RO