SearcharxivSearch

arXiv subjects

M. van Beuzekom

Publications and source records attributed to M. van Beuzekom.

At least 19 recordsLinked to original sources

Testbeam characterization of a 3D silicon sensor read out by Timepix4

Testbeam results from a $300\,μ\mathrm{m}$-thick 3D silicon sensor bump-bonded to a Timepix4 ASIC, are presented. The hit detection efficiency, spatial resolution, and timing performance of the 3D sensor are studied for several track angles, bias voltages and charge thresholds. The time measurements are corrected for Timepix4 clock-frequency variations and timewalk, while for the spatial studies, nonlinear charge-sharing corrections are determined. At perpendicular incidence, the time resolution of the 3D detector is equal to $245\,\mathrm{ps}$ with a $97\%$ hit detection efficiency. An optimal angle of $8^\circ$ with respect to the beam direction of the 3D detector was found, in which the time resolution improves by $6\%$ compared to normal incidence, while the hit detection efficiency reaches above $99\%$ and the spatial resolution is approximately $7\,μ\mathrm{m}$. Intrapixel studies show that a time resolution of $153\,\mathrm{ps}$ at the most probable value of the signal charge can be achieved for hits between the electrodes at normal incidence, while the timing performance of these best-performing regions deteriorate upon sensor rotation. The timing properties at different depths of the 3D sensor have been investigated with tracks at grazing-angle incidence, revealing a dependence of the time resolution along the sensor depth.

physics.ins-det

Evidence for CP violation in $B^+\to p \bar p K^+$ decays

Three-body $B^+\to p \overline p K^+$ and $B^+\to p \overline p π^+$ decays are studied using a data sample corresponding to an integrated luminosity of 3.0 $fb^{-1}$ collected by the LHCb experiment in proton-proton collisions at center-of-mass energies of $7$ and $8$ TeV. Evidence of CP violation in the $B^+\to p \overline p K^+$ decay is found in regions of the phase space, representing the first measurement of this kind for a final state containing baryons. Measurements of the forward-backward asymmetry of the light meson in the $p\overline p$ rest frame yield $A_{\mathrm{FB}}(p \overline p K^+,~m_{p\overline p}<2.85\mathrm{\,Ge\kern -0.1em V\!/}c^2)=0.495\pm0.012~(\mathrm{stat})\pm0.007~(\mathrm{syst})$ and $A_{\mathrm{FB}}(p\overline p π^+,~m_{p\overline p}<2.85\mathrm{\,Ge\kern -0.1em V\!/}c^2)=-0.409\pm0.033~(\mathrm{stat})\pm0.006~(\mathrm{syst})$. In addition, the branching fraction of the decay $B^+\to\kern 0.1em\overline{\kern -0.1emΛ}(1520)p$ is measured to be $\mathcal{B}(B^+ \to \kern 0.1em\overline{\kern -0.1emΛ}(1520)p)=(3.15\pm0.48~(\mathrm{stat})\pm0.07~(\mathrm{syst})\pm0.26~(\mathrm{BF}))\times 10^{-7}$, where BF denotes the uncertainty on secondary branching fractions.

hep-ex

Embedding the Timepix4 in Micro-Pattern Gaseous Detectors

The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous because of its size (around 7 cm^2 active area) and its Through Silicon Vias. The latter enables to connect to the Timepix4 from the back side. Thus, it can be tiled on four sides, allowing it to cover large areas without loss of active area. Here, the first results of reading out MPGDs with the Timepix4 are presented. Measurements with a Gas Electron Multiplier (GEM) detector show that event selection based on geometrical parameters of the interaction is possible, X-ray imaging studies can be performed, as well as energy and time-resolved measurements. In parallel, the embedding of a Timepix4 into a micro-resistive Well (uRWell) amplification structure is explored. The first mechanical tests have been successful. The status of the electrical functionality is presented, as well as simulation studies on the signal induction in such a device.

physics.ins-det

Measurements of charm mixing and $C\!P$ violation using $D^0 \to K^\pm π^\mp$ decays

Measurements of charm mixing and $C\!P$ violation parameters from the decay-time-dependent ratio of $ D^0 \to K^+ π^- $ to $ D^0 \to K^- π^+ $ decay rates and the charge-conjugate ratio are reported. The analysis uses $\overline{B}\to D^{*+} μ^- X$, and charge-conjugate decays, where $D^{*+}\to D^0 π^+$, and $D^0\to K^{\mp} π^{\pm}$. The $pp$ collision data are recorded by the LHCb experiment at center-of-mass energies $\sqrt{s}$ = 7 and 8 TeV, corresponding to an integrated luminosity of 3 fb$^{-1}$. The data are analyzed under three hypotheses: (i) mixing assuming $C\!P$ symmetry, (ii) mixing assuming no direct $C\!P$ violation in the Cabibbo-favored or doubly Cabibbo-suppressed decay amplitudes, and (iii) mixing allowing either direct $C\!P$ violation and/or $C\!P$ violation in the superpositions of flavor eigenstates defining the mass eigenstates. The data are also combined with those from a previous LHCb study of $D^0\to K π$ decays from a disjoint set of $ D^{*+} $ candidates produced directly in $pp$ collisions. In all cases, the data are consistent with the hypothesis of $C\!P$ symmetry.

hep-ex

Towards MPGDs with embedded pixel ASICs

Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low material budget, X-ray polarimetry at low energies ($\lessapprox$ 2 keV) or rare-event searches which profit from event selection based on geometrical parameters. In this article, the idea of embedding a pixel ASIC - specifically the Timepix4 - into a micro-pattern gaseous amplification stage is illustrated. Furthermore, the first results of reading out a triple-GEM detector with the Timepix4 (GEMPix4) are shown, including the first X-ray images taken with a Timepix4 utilising Through Silicon Vias (TSVs). Lastly, a new readout concept is presented, called the 'Silicon Readout Board', extending the use of pixel ASICs to read out gaseous detectors to a wider range of HEP applications.

physics.ins-det

The LHCb VELO Upgrade Module Construction

The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon detector modules which operate in vacuum close to the LHC beam in a high radiation environment. The construction and quality assurance tests of these modules are described in this paper. The modules incorporate 200 \mum thick, n-on-p silicon sensors bump-bonded to 130 \nm technology ASICs. These are attached with high precision to a silicon microchannel substrate that uses evaporative CO$_2$ cooling. The ASICs are controlled and read out with flexible printed circuits that are glued to the substrate and wire-bonded to the chips. The mechanical support of the module is given by a carbon fibre plate, two carbon fibre rods and an aluminium plate. The sensor attachment was achieved with an average precision of 21 $\mathrm{μm}$, more than 99.5\% of all pixels are fully functional, and a thermal figure of merit of 3 \mathrm{Kcm^{2}W^{-1}}$ was achieved. The production of the modules was successfully completed in 2021, with the final assembly and installation completed in time for data taking in 2022.

physics.ins-det

Radiation Tolerance of Low-Noise Photoreceivers for the LISA Space Mission

This study investigates the effects of space environmental radiation on the performance of InGaAs Quadrant Photodiodes (QPDs) and assesses their suitability for the Laser Interferometer Space Antenna (LISA) mission. QPDs of 1.0, 1.5 and 2.0 mm have been irradiated with 20 and 60 MeV protons, 0.5 and 1 MeV electrons, and Co$^{60}$ gamma. An exposure corresponding to a displacement damage equivalent fluence of $1.0 \times 10^{+12}$ p/cm$^2$ for 20 and 60 MeV protons and a total ionizing dose of 237 krad were applied, surpassing the anticipated radiation levels for the LISA mission by a factor of approximately five. Experiments were conducted to measure changes in QPD dark current, capacitance, and responsivity. The QPDs are integrated with a low-noise DC-coupled transimpedance amplifier to form the Photoreceiver (QPR). QPR noise and performance in an interferometric system like LISA were also measured. Although radiation impacted their dark current and responsivity, almost all QPDs met LISA's validation criteria and did not demonstrate any critical failure. These findings prove that the tested QPDs are promising candidates for LISA and other space-based missions.

physics.ins-det

Timing performance of the Timepix4 front-end

A characterisation of the Timepix4 pixel front-end with a strong focus on timing performance is presented. Externally generated test pulses were used to probe the per-pixel time-to-digital converter (TDC) and measure the time-bin sizes by precisely controlling the test-pulse arrival time in steps of 10 ps. The results indicate that the TDC can achieve a time resolution of 60 ps, provided that a calibration is performed to compensate for frequency variation in the voltage controlled oscillators of the pixel TDCs. The internal clock distribution system of Timepix4 was used to control the arrival time of internally generated analog test pulses in steps of about 20 ps. The analog test pulse mechanism injects a controlled amount of charge directly into the analog front-end (AFE) of the pixel, and was used to measure the time resolution as a function of signal charge, independently of the TDC. It was shown that for the default configuration, the AFE time resolution in the hole-collecting mode is limited to 105 ps. However, this can be improved up to about 60 ps by increasing the preamplifier bias-current at the cost of increased power dissipation. For the electron-collecting mode, an AFE time resolution of 47 ps was measured for a bare Timepix4 device at a signal charge of 21 ke. It was observed that additional input capacitance from a bonded sensor reduces this figure to 62 ps.

physics.ins-det

ETpathfinder: a cryogenic testbed for interferometric gravitational-wave detectors

The third-generation of gravitational wave observatories, such as the Einstein Telescope (ET) and Cosmic Explorer (CE), aim for an improvement in sensitivity of at least a factor of ten over a wide frequency range compared to the current advanced detectors. In order to inform the design of the third-generation detectors and to develop and qualify their subsystems, dedicated test facilities are required. ETpathfinder prototype uses full interferometer configurations and aims to provide a high sensitivity facility in a similar environment as ET. Along with the interferometry at 1550 nm and silicon test masses, ETpathfinder will focus on cryogenic technologies, lasers and optics at 2090 nm and advanced quantum-noise reduction schemes. This paper analyses the underpinning noise contributions and combines them into full noise budgets of the two initially targeted configurations: 1) operating with 1550 nm laser light and at a temperature of 18 K and 2) operating at 2090 nm wavelength and a temperature of 123 K.

astro-ph.IM

Spatial resolution and efficiency of prototype sensors for the LHCb VELO Upgrade

A comprehensive study of the spatial resolution and detection efficiency of sensor prototypes developed for the LHCb VELO upgrade is presented. Data samples were collected at the CERN SPS H8 beam line using a hadron mixture of protons and pions with momenta of approximately 180 GeV/c. The sensor performance was characterised using both irradiated and non-irradiated sensors. Irradiated samples were subjected to a maximum fluence of $\mathrm{8\times10^{15}~1~MeV~n_{eq}~cm^{-2}}$, of both protons and neutrons. The spatial resolution is measured comparing the detected hits to the position as predicted by tracks reconstructed by the Timepix3 telescope. The resolution is presented for different applied bias voltages and track angles, sensor thickness and implant size.

physics.ins-det

Charge and temporal characterisation of silicon sensors using a two-photon absorption laser

First measurements are presented from a newly commissioned two-photon absorption (TPA) setup at Nikhef. The characterisation of the various components of the system is discussed. Two planar silicon sensors, one being electron collecting and one hole collecting, are characterised with detailed measurements of the charge collection and time resolution. The TPA spot is determined to have a radius of 0.975(11) $μ\text{m}$ and length of 23.8 $μ\text{m}$ in silicon. The trigger time resolution of the system is shown to be maximally 30.4 ps. For both sensors, uniform charge collection is observed over the pixels, and the pixel side metallisation is imaged directly using the TPA technique. The best time resolution for a single pixel is found to be 600 ps and 560 ps for the electron and hole collecting sensors respectively, and is dominated by ASIC contributions. Further scans at different depths in the sensor and positions within the pixels have been performed and show a uniform response. It is concluded that the TPA setup is a powerful tool to investigate the charge collection and temporal properties of silicon sensors.

physics.ins-det

Timing measurements with a 3D silicon sensor on Timepix3 in a 180 GeV/c hadron beam

Test beam measurements have been carried out with a 3D sensor on a Timepix3 ASIC and the time measurements are presented. The measurements are compared to those of a thin planar sensor on Timepix3. It is shown that for a perpendicularly incident beam the time resolution of both detectors is dominated by the Timepix3 front-end. The 3D detector is dominated by the time-to-digital conversion whereas the analog front-end jitter also gives a significant contribution for the thin planar detector. The 3D detector reaches an overall time resolution of 567(6)ps compared to 683(8)ps for the thin planar detector. For a grazing angle beam, however, the thin planar detector achieves a better time resolution because it has a lower pixel capacitance, and therefore suffers less from jitter in the analog front-end for the low charge signals that mainly occur in this type of measurement. Finally, it is also shown that the 3D and thin planar detector can achieve time resolutions for large clusters of about 100ps and 250ps, respectively, by combining many single hit measurements.

physics.ins-det

Charge collection properties of prototype sensors for the LHCb VELO upgrade

An extensive sensor testing campaign is presented, dedicated to measuring the charge collection properties of prototype candidates for the Vertex Locator (VELO) detector for the upgraded LHCb experiment. The charge collection is measured with sensors exposed to fluences of up to $8 \times 10^{15}~1~\mathrm{\,Me\kern -0.1em V}~ \mathrm{ \,n_{eq}}~{\mathrm{ \,cm}}^{-2}$, as well as with nonirradiated prototypes. The results are discussed, including the influence of different levels of irradiation and bias voltage on the charge collection properties. Charge multiplication is observed on some sensors that were nonuniformly irradiated with 24 GeV protons, to the highest fluence levels. An analysis of the charge collection near the guard ring region is also presented, revealing significant differences between the sensor prototypes. All tested sensor variants succeed in collecting the minimum required charge of 6000 electrons after the exposure to the maximum fluence.

physics.ins-det

Timing performance of the LHCb VELO Timepix3 Telescope

We performed a detailed study of the timing performance of the LHCb VELO Timepix3 Telescope with a 180 GeV/c mixed hadron beam at the CERN SPS. A twofold method was developed to improve the resolution of single-plane time measurements, resulting in a more precise overall track time measurement. The first step uses spatial information of reconstructed tracks in combination with the measured signal charge in the sensor to correct for a mixture of different effects: variations in charge carrier drift time; variations in signal induction, which are the result of a non-uniform weighting field in the pixels; and lastly, timewalk in the analog front-end. The second step corrects for systematic timing offsets in Timepix3 that vary from -2 ns to 2 ns. By applying this method, we improved the track time resolution from 438$\,\pm\,$16 ps to 276$\,\pm\,$4 ps.

physics.ins-det

Measurement of psi(2S) meson production in pp collisions at sqrt(s)=7 TeV

The differential cross-section for the inclusive production of psi(2S) mesons in pp collisions at sqrt(s)=7 TeV has been measured with the LHCb detector. The data sample corresponds to an integrated luminosity of 36 pb-1. The psi(2S) mesons are reconstructed in the decay channels psi(2S) -> mu+ mu- and psi(2S) -> J/psi pi+ pi-, with the J/psi meson decaying into two muons. Results are presented both for promptly produced psi(2S) mesons and for those originating from b-hadron decays. In the kinematic range pT(psi(2S)) <= 16 GeV/c and 2 < y(psi(2S)) <= 4.5 we measure 1.44 +- 0.01 +- 0.12+0.2-0.4 mub for prompt psi(2S) production and 0.25 +- 0.01 +- 0.02 mub for psi(2S) from b-hadron decays, where the last uncertainty on the prompt cross-section is due to the unknown psi(2S) polarization. Recent QCD calculations are found to be in good agreement with our measurements. Combining the present result with the LHCb J/psi measurements we determine the inclusive branching fraction B(b -> psi(2S) X) = (2.73 +- 0.06 +- 0.16 +- 0.24) x 10^(-3), where the last uncertainty is due to the B(b -> J/psi X), B(J/psi -> mu+ mu-) and B(psi(2S) -> e+ e-) branching fraction uncertainties. All above results are corrected by an erratum included as an appendix.

hep-ex

Updated measurement of time-dependent $CP$-violating observables in $B^{0}_{s}\to J/ψK^+ K^-$ decays

The decay-time-dependent $CP$ asymmetry in $B^{0}_{s}\to J/ψK^{+} K^{-}$ decays is measured using proton-proton collision data, corresponding to an integrated luminosity of $1.9\,\mathrm{fb^{-1}}$, collected with the LHCb detector at a centre-of-mass energy of $13\,\mathrm{TeV}$ in 2015 and 2016. Using a sample of approximately 117\,000 signal decays with an invariant $K^{+} K^{-}$ mass in the vicinity of the $ϕ(1020)$ resonance, the $CP$-violating phase $ϕ_s$ is measured, along with the difference in decay widths of the light and heavy mass eigenstates of the $B^{0}_{s}$-$\bar{B}^{0}_{s}$ system, $ΔΓ_s$. The difference of the average $B^{0}_{s}$ and $B^{0}$ meson decay widths, $Γ_s-Γ_d$, is determined using in addition a sample of $B^{0} \to J/ψK^{+} π^{-}$ decays. The values obtained are $ϕ_s = -0.083\pm0.041\pm0.006\,\mathrm{rad}$, $ΔΓ_s = 0.077 \pm 0.008 \pm 0.003\, \mathrm{ps^{-1}}$ and $Γ_s-Γ_d = -0.0041 \pm 0.0024 \pm 0.0015\,\mathrm{ps^{-1}}$, where the first uncertainty is statistical and the second systematic. These are the most precise single measurements of these quantities to date and are consistent with expectations based on the Standard Model and with a previous LHCb analysis of this decay using data recorded at centre-of-mass energies 7 and 8 TeV. Finally, the results are combined with recent results from $B^{0}_{s}\to J/ψπ^{+} π^{-}$ decays obtained using the same dataset as this analysis, and with previous independent LHCb results.

hep-ex

Measurement of the $η_c(1S)$ production cross-section in $pp$ collisions at $\sqrt{s} = 13$ TeV

Using a data sample corresponding to an integrated luminosity of $2.0\,fb^{-1}$, collected by the LHCb experiment, the production of the $η_c(1S)$ state in proton-proton collisions at a centre-of-mass energy of $\sqrt{s}=13 \text{ TeV}$ is studied in the rapidity range ${2.0 < y < 4.5}$ and in the transverse momentum range ${6.5 < p_{T} < 14.0\text{ GeV}}$. The cross-section for prompt production of $η_c(1S)$ mesons relative to that of the $J/ψ$ meson is measured using the ${p\bar{p}}$ decay mode and is found to be ${σ_{η_c(1S)}/σ_{J/ψ} = 1.69 \pm 0.15 \pm 0.10 \pm 0.18}$. The quoted uncertainties are, in order, statistical, systematic and due to uncertainties on the branching fractions of the ${J/ψ\to p \bar{p}}$ and ${η_c\to p \bar{p}}$ decays. The prompt $η_c(1S)$ production cross-section is determined to be ${σ_{η_c(1S)} = 1.26 \pm 0.11\pm 0.08 \pm 0.14 \,μb}$, where the last uncertainty includes that on the ${J/ψ}$ meson cross-section. The ratio of the branching fractions of $b$-hadron decays to the $η_c(1S)$ and ${J/ψ}$ states is measured to be ${\mathcal{B}_{b\toη_c X}/\mathcal{B}_{b\to J/ψX} = 0.48 \pm 0.03 \pm 0.03 \pm 0.05}$, where the last uncertainty is due to those on the branching fractions of the ${J/ψ\to p \bar{p}}$ and ${η_c\to p \bar{p}}$ decays. The difference between the ${J/ψ}$ and $η_c(1S)$ masses is also determined to be ${113.0 \pm 0.7 \pm 0.1\text{ MeV}}$, which is the most precise single measurement of this quantity to date.

hep-ex