SearcharxivSearch

arXiv subjects

Madhurananda Pahar

Publications and source records attributed to Madhurananda Pahar.

13 recordsLinked to original sources

CCMAN: Cognitive Instability-Aware Cross-Modal Attention Network for Interpretable Temporal Biomarkers of Verbal Fluency Speech

Early detection of cognitive decline from speech offers a scalable and non-invasive alternative to conventional clinical assessment. Verbal fluency tasks are particularly informative, but most automated approaches aggregate features across an entire recording, overlooking temporal speech dynamics. We propose the Cognitive Instability-Aware Cross-Modal Attention Network (CCMAN), a transfer learning framework that learns task-agnostic cognitive speech representations from multiple memory-probing tasks before fine-tuning on a minute-long semantic and phonemic verbal fluency task. CCMAN integrates semantic, acoustic, and linguistic information through bidirectional cross-attention, gated multimodal fusion, and transformer-based temporal modelling to derive interpretable biomarkers of cognitive decline. Experiments were conducted on 165.44 hours of speech from 843 participants (498 healthy controls, 245 with mild cognitive impairment, and 100 with dementia). CCMAN achieved Macro-F1 scores of 0.81 and 0.59 for binary and multiclass semantic fluency classification, and 0.77 and 0.53 for phonemic fluency, consistently outperforming strong static and temporal baselines. Statistical analyses showed that semantic drift variance and pause variance, but not mean semantic drift, were significantly elevated in both MCI and dementia relative to healthy controls, while pause duration increased progressively over the task with the steepest slope in dementia, supporting global and progressive temporal speech instability as interpretable biomarkers. Evaluation on the independent PROCESS-2 benchmark further demonstrated the generalisability of the proposed framework, improving the baseline Macro-F1 by up to 9%. These findings support temporal speech instability as a dynamic speech biomarker for robust, interpretable, and generalisable early detection of cognitive decline.

cs.SD

False positive bias in AI-powered speech-based cognitive screening for multilingual English speakers in the UK

Conversational speech reveals early signs of cognitive decline, including dementia and mild cognitive impairment (MCI). AI models show promise for speech-based screening, yet most research focuses on monolingual groups. In the UK, dementia is projected to rise fastest among Black and Asian communities, where multilingualism is common, making equity assessment critical. We recruited 1,395 participants (monolingual English speakers and multilingual speakers from Sheffield/Bradford) and collected over 263 hours of speech via the CognoMemory agent. Multilingual participants spoke English alongside Somali, Chinese, or South Asian languages (Hindi, Urdu, Punjabi, Mirpuri, Arabic). We evaluated ASR (Whisper, Wav2Vec 2.0, NeMo) and downstream AI models for cognitive classification and MMSE regression. ASR accuracy showed no significant differences across groups. However, downstream models exhibited systematic disparities: multilingual speakers were more often misclassified as impaired, especially in memory, fluency, and reading tasks. False-positive rates were substantially higher for multilingual (28 to 37%) than monolingual (12 to 16%) speakers, meaning multilingual individuals were approximately 2.5 times more likely to receive incorrect impairment labels. These biases worsened when models were trained on DementiaBank. This is the first large-scale analysis of false-positive bias in speech-based AI cognitive screening for UK multilingual ethnic minorities. Despite strong overall performance, current models show measurable disparities affecting multilingual speakers. Addressing these biases is essential for safe, equitable deployment in diverse healthcare settings.

cs.CL

PROCESS-2: A Benchmark Speech Corpus for Early Cognitive Impairment Detection

Speech-based analysis offers a scalable and non-invasive approach for detecting cognitive decline, yet progress has been constrained by the limited availability of clinically validated datasets collected under realistic conditions. We introduce PROCESS-2, a large-scale speech dataset designed to support research on automatic assessment of cognitive impairment from spontaneous and task-oriented speech. The dataset comprises recordings from 200 healthy controls, 150 mild cognitive impairment, and 50 dementia diagnoses collected using the CognoMemory digital assessment platform. Each participant completed a single assessment session, including picture description and verbal fluency tasks, accompanied by manually verified transcripts and participant-level metadata. PROCESS-2 contains approximately 21 hours of speech audio with predefined train/test partitions. Comprehensive technical validation evaluated demographic balance, clinical consistency, recording stability, embedding-space structure, and reproducible baseline modelling performance, demonstrating clinically meaningful group separation and stable performance across modelling approaches while preserving real-world conversational variability. PROCESS-2 is released under controlled access via Hugging Face to enable responsible reuse while protecting participant privacy, providing a reproducible benchmark resource for speech-based cognitive assessment research.

cs.SD

CognoSpeak: an automatic, remote assessment of early cognitive decline in real-world conversational speech

The early signs of cognitive decline are often noticeable in conversational speech, and identifying those signs is crucial in dealing with later and more serious stages of neurodegenerative diseases. Clinical detection is costly and time-consuming and although there has been recent progress in the automatic detection of speech-based cues, those systems are trained on relatively small databases, lacking detailed metadata and demographic information. This paper presents CognoSpeak and its associated data collection efforts. CognoSpeak asks memory-probing long and short-term questions and administers standard cognitive tasks such as verbal and semantic fluency and picture description using a virtual agent on a mobile or web platform. In addition, it collects multimodal data such as audio and video along with a rich set of metadata from primary and secondary care, memory clinics and remote settings like people's homes. Here, we present results from 126 subjects whose audio was manually transcribed. Several classic classifiers, as well as large language model-based classifiers, have been investigated and evaluated across the different types of prompts. We demonstrate a high level of performance; in particular, we achieved an F1-score of 0.873 using a DistilBERT model to discriminate people with cognitive impairment (dementia and people with mild cognitive impairment (MCI)) from healthy volunteers using the memory responses, fluency tasks and cookie theft picture description. CognoSpeak is an automatic, remote, low-cost, repeatable, non-invasive and less stressful alternative to existing clinical cognitive assessments.

cs.SD

Early Dementia Detection Using Multiple Spontaneous Speech Prompts: The PROCESS Challenge

Dementia is associated with various cognitive impairments and typically manifests only after significant progression, making intervention at this stage often ineffective. To address this issue, the Prediction and Recognition of Cognitive Decline through Spontaneous Speech (PROCESS) Signal Processing Grand Challenge invites participants to focus on early-stage dementia detection. We provide a new spontaneous speech corpus for this challenge. This corpus includes answers from three prompts designed by neurologists to better capture the cognition of speakers. Our baseline models achieved an F1-score of 55.0% on the classification task and an RMSE of 2.98 on the regression task.

cs.SD

Wake-Cough: cough spotting and cougher identification for personalised long-term cough monitoring

We present `wake-cough', an application of wake-word spotting to coughs using a Resnet50 and the identification of coughers using i-vectors, for the purpose of a long-term, personalised cough monitoring system. Coughs, recorded in a quiet (73$\pm$5 dB) and noisy (34$\pm$17 dB) environment, were used to extract i-vectors, x-vectors and d-vectors, used as features to the classifiers. The system achieves 90.02\% accuracy when using an MLP to discriminate between 51 coughers using 2-sec long cough segments in the noisy environment. When discriminating between 5 and 14 coughers using longer (100 sec) segments in the quiet environment, this accuracy improves to 99.78% and 98.39% respectively. Unlike speech, i-vectors outperform x-vectors and d-vectors in identifying coughers. These coughs were added as an extra class to the Google Speech Commands dataset and features were extracted by preserving the end-to-end time-domain information in a trigger phrase. The highest accuracy of 88.58% is achieved in spotting coughs among 35 other trigger phrases using a Resnet50. Thus, wake-cough represents a personalised, non-intrusive cough monitoring system, which is power-efficient as on-device wake-word detection can keep a smartphone-based monitoring device mostly dormant. This makes wake-cough extremely attractive in multi-bed ward environments to monitor patients' long-term recovery from lung ailments such as tuberculosis (TB) and COVID-19.

cs.SD

Automatic Tuberculosis and COVID-19 cough classification using deep learning

We present a deep learning based automatic cough classifier which can discriminate tuberculosis (TB) coughs from COVID-19 coughs and healthy coughs. Both TB and COVID-19 are respiratory diseases, contagious, have cough as a predominant symptom and claim thousands of lives each year. The cough audio recordings were collected at both indoor and outdoor settings and also uploaded using smartphones from subjects around the globe, thus containing various levels of noise. This cough data include 1.68 hours of TB coughs, 18.54 minutes of COVID-19 coughs and 1.69 hours of healthy coughs from 47 TB patients, 229 COVID-19 patients and 1498 healthy patients and were used to train and evaluate a CNN, LSTM and Resnet50. These three deep architectures were also pre-trained on 2.14 hours of sneeze, 2.91 hours of speech and 2.79 hours of noise for improved performance. The class-imbalance in our dataset was addressed by using SMOTE data balancing technique and using performance metrics such as F1-score and AUC. Our study shows that the highest F1-scores of 0.9259 and 0.8631 have been achieved from a pre-trained Resnet50 for two-class (TB vs COVID-19) and three-class (TB vs COVID-19 vs healthy) cough classification tasks, respectively. The application of deep transfer learning has improved the classifiers' performance and makes them more robust as they generalise better over the cross-validation folds. Their performances exceed the TB triage test requirements set by the world health organisation (WHO). The features producing the best performance contain higher order of MFCCs suggesting that the differences between TB and COVID-19 coughs are not perceivable by the human ear. This type of cough audio classification is non-contact, cost-effective and can easily be deployed on a smartphone, thus it can be an excellent tool for both TB and COVID-19 screening.

cs.LG

Accelerometer-based Bed Occupancy Detection for Automatic, Non-invasive Long-term Cough Monitoring

We present a new machine learning based bed-occupancy detection system that uses the accelerometer signal captured by a bed-attached consumer smartphone. Automatic bed-occupancy detection is necessary for automatic long-term cough monitoring, since the time which the monitored patient occupies the bed is required to accurately calculate a cough rate. Accelerometer measurements are more cost effective and less intrusive than alternatives such as video monitoring or pressure sensors. A 249-hour dataset of manually-labelled acceleration signals gathered from seven patients undergoing treatment for tuberculosis (TB) was compiled for experimentation. These signals are characterised by brief activity bursts interspersed with long periods of little or no activity, even when the bed is occupied. To process them effectively, we propose an architecture consisting of three interconnected components. An occupancy-change detector locates instances at which bed occupancy is likely to have changed, an occupancy-interval detector classifies periods between detected occupancy changes and an occupancy-state detector corrects falsely-identified occupancy changes. Using long short-term memory (LSTM) networks, this architecture was demonstrated to achieve an AUC of 0.94. When integrated into a complete cough monitoring system, the daily cough rate of a patient undergoing TB treatment was determined over a period of 14 days. As the colony forming unit (CFU) counts decreased and the time to positivity (TPP) increased, the measured cough rate decreased, indicating effective TB treatment. This provides a first indication that automatic cough monitoring based on bed-mounted accelerometer measurements may present a non-invasive, non-intrusive and cost-effective means of monitoring long-term recovery of TB patients.

cs.LG

Automatic Cough Classification for Tuberculosis Screening in a Real-World Environment

Objective: The automatic discrimination between the coughing sounds produced by patients with tuberculosis (TB) and those produced by patients with other lung ailments. Approach: We present experiments based on a dataset of 1358 forced cough recordings obtained in a developing-world clinic from 16 patients with confirmed active pulmonary TB and 35 patients suffering from respiratory conditions suggestive of TB but confirmed to be TB negative. Using nested cross-validation, we have trained and evaluated five machine learning classifiers: logistic regression (LR), support vector machines (SVM), k-nearest neighbour (KNN), multilayer perceptrons (MLP) and convolutional neural networks (CNN). Main Results: Although classification is possible in all cases, the best performance is achieved using LR. In combination with feature selection by sequential forward selection (SFS), our best LR system achieves an area under the ROC curve (AUC) of 0.94 using 23 features selected from a set of 78 high-resolution mel-frequency cepstral coefficients (MFCCs). This system achieves a sensitivity of 93\% at a specificity of 95\% and thus exceeds the 90\% sensitivity at 70\% specificity specification considered by the World Health Organisation (WHO) as a minimal requirement for a community-based TB triage test. Significance: The automatic classification of cough audio sounds, when applied to symptomatic patients requiring investigation for TB, can meet the WHO triage specifications for the identification of patients who should undergo expensive molecular downstream testing. This makes it a promising and viable means of low cost, easily deployable frontline screening for TB, which can benefit especially developing countries with a heavy TB burden.

cs.SD

Automatic non-invasive Cough Detection based on Accelerometer and Audio Signals

We present an automatic non-invasive way of detecting cough events based on both accelerometer and audio signals. The acceleration signals are captured by a smartphone firmly attached to the patient's bed, using its integrated accelerometer. The audio signals are captured simultaneously by the same smartphone using an external microphone. We have compiled a manually-annotated dataset containing such simultaneously-captured acceleration and audio signals for approximately 6000 cough and 68000 non-cough events from 14 adult male patients in a tuberculosis clinic. LR, SVM and MLP are evaluated as baseline classifiers and compared with deep architectures such as CNN, LSTM, and Resnet50 using a leave-one-out cross-validation scheme. We find that the studied classifiers can use either acceleration or audio signals to distinguish between coughing and other activities including sneezing, throat-clearing, and movement on the bed with high accuracy. However, in all cases, the deep neural networks outperform the shallow classifiers by a clear margin and the Resnet50 offers the best performance by achieving an AUC exceeding 0.98 and 0.99 for acceleration and audio signals respectively. While audio-based classification consistently offers a better performance than acceleration-based classification, we observe that the difference is very small for the best systems. Since the acceleration signal requires less processing power, and since the need to record audio is sidestepped and thus privacy is inherently secured, and since the recording device is attached to the bed and not worn, an accelerometer-based highly accurate non-invasive cough detector may represent a more convenient and readily accepted method in long-term cough monitoring.

cs.SD

COVID-19 Detection in Cough, Breath and Speech using Deep Transfer Learning and Bottleneck Features

We present an experimental investigation into the effectiveness of transfer learning and bottleneck feature extraction in detecting COVID-19 from audio recordings of cough, breath and speech. This type of screening is non-contact, does not require specialist medical expertise or laboratory facilities and can be deployed on inexpensive consumer hardware. We use datasets that contain recordings of coughing, sneezing, speech and other noises, but do not contain COVID-19 labels, to pre-train three deep neural networks: a CNN, an LSTM and a Resnet50. These pre-trained networks are subsequently either fine-tuned using smaller datasets of coughing with COVID-19 labels in the process of transfer learning, or are used as bottleneck feature extractors. Results show that a Resnet50 classifier trained by this transfer learning process delivers optimal or near-optimal performance across all datasets achieving areas under the receiver operating characteristic (ROC AUC) of 0.98, 0.94 and 0.92 respectively for all three sound classes (coughs, breaths and speech). This indicates that coughs carry the strongest COVID-19 signature, followed by breath and speech. Our results also show that applying transfer learning and extracting bottleneck features using the larger datasets without COVID-19 labels led not only to improve performance, but also to minimise the standard deviation of the classifier AUCs among the outer folds of the leave-$p$-out cross-validation, indicating better generalisation. We conclude that deep transfer learning and bottleneck feature extraction can improve COVID-19 cough, breath and speech audio classification, yielding automatic classifiers with higher accuracy.

cs.SD

COVID-19 Cough Classification using Machine Learning and Global Smartphone Recordings

We present a machine learning based COVID-19 cough classifier which can discriminate COVID-19 positive coughs from both COVID-19 negative and healthy coughs recorded on a smartphone. This type of screening is non-contact, easy to apply, and can reduce the workload in testing centres as well as limit transmission by recommending early self-isolation to those who have a cough suggestive of COVID-19. The datasets used in this study include subjects from all six continents and contain both forced and natural coughs, indicating that the approach is widely applicable. The publicly available Coswara dataset contains 92 COVID-19 positive and 1079 healthy subjects, while the second smaller dataset was collected mostly in South Africa and contains 18 COVID-19 positive and 26 COVID-19 negative subjects who have undergone a SARS-CoV laboratory test. Both datasets indicate that COVID-19 positive coughs are 15\%-20\% shorter than non-COVID coughs. Dataset skew was addressed by applying the synthetic minority oversampling technique (SMOTE). A leave-$p$-out cross-validation scheme was used to train and evaluate seven machine learning classifiers: LR, KNN, SVM, MLP, CNN, LSTM and Resnet50. Our results show that although all classifiers were able to identify COVID-19 coughs, the best performance was exhibited by the Resnet50 classifier, which was best able to discriminate between the COVID-19 positive and the healthy coughs with an area under the ROC curve (AUC) of 0.98. An LSTM classifier was best able to discriminate between the COVID-19 positive and COVID-19 negative coughs, with an AUC of 0.94 after selecting the best 13 features from a sequential forward selection (SFS). Since this type of cough audio classification is cost-effective and easy to deploy, it is potentially a useful and viable means of non-contact COVID-19 screening.

cs.SD

Deep Neural Network based Cough Detection using Bed-mounted Accelerometer Measurements

We have performed cough detection based on measurements from an accelerometer attached to the patient's bed. This form of monitoring is less intrusive than body-attached accelerometer sensors, and sidesteps privacy concerns encountered when using audio for cough detection. For our experiments, we have compiled a manually-annotated dataset containing the acceleration signals of approximately 6000 cough and 68000 non-cough events from 14 adult male patients in a tuberculosis clinic. As classifiers, we have considered convolutional neural networks (CNN), long-short-term-memory (LSTM) networks, and a residual neural network (Resnet50). We find that all classifiers are able to distinguish between the acceleration signals due to coughing and those due to other activities including sneezing, throat-clearing and movement in the bed with high accuracy. The Resnet50 performs the best, achieving an area under the ROC curve (AUC) exceeding 0.98 in cross-validation experiments. We conclude that high-accuracy cough monitoring based only on measurements from the accelerometer in a consumer smartphone is possible. Since the need to gather audio is avoided and therefore privacy is inherently protected, and since the accelerometer is attached to the bed and not worn, this form of monitoring may represent a more convenient and readily accepted method of long-term patient cough monitoring.

cs.LG