Magdalena Rafecas

Publications and source records attributed to Magdalena Rafecas.

6 recordsLinked to original sources

MERMAID-v1 PET Scanner Prototype: Initial Characterization and First Zebrafish Scans

MERMAID-v1 is a prototype PET scanner designed to support biomedical research involving adult zebrafish and similar species. The current experimental setup has been characterized, and scans of various phantoms, as well as adult zebrafish have been conducted. A dedicated reconstruction software was implemented, including accurate modeling of the parallax effect. The average energy resolution was 21.6% (FWHM at 511keV), with no significant dead-time effects observed for activities up to 18MBq. The absolute sensitivity at the center of the field of view (FOV) ranged from 0.06% to 0.31%, depending on the energy window (from 450-550 to 300-600keV), reflecting the limitations of the current two-head configuration. In the central 12mm of the transaxial FOV, the averaged spatial resolution is approximately 0.77mm (FWHM) transaxially and 0.66mm axially, as evaluated using a point source. Image quality was assessed using a downscaled NEMA-inspired IQ phantom and a 3D-printed Derenzo phantom. The reconstructed images suggest a spatial resolution around 0.7mm - 0.8mm, despite the lack of depth-of-interaction information. The first ex- and in-vivo PET scans of adult zebrafish were successfully performed, showing detectable tracer uptake in organs such as the brain and eyes despite low initial activity levels. These results confirm MERMAID-v1 capability to obtain useful results from the acquired data from living, anesthetized fish in a water-filled imaging chamber. While no scatter, attenuation, or efficiency corrections have yet been implemented, this work establishes a working proof-of-concept for dedicated PET imaging of small aquatic vertebrates. Future developments will focus on developing correction techniques, expanding the detector array, and integrating complementary modalities such as CT.

physics.med-ph

Inclusion of Inter-crystal Scattering in PET: Analytical Models and Dedicated Reconstruction

Inter-crystal scattering (ICS) in Positron Emission Tomography (PET) is commonly regarded as a degradation effect that might compromise the image spatial resolution. In parallel, the inclusion of ICS events has also been recognized as a potential approach to increase PET sensitivity, which could be especially beneficial in scenarios where the latter is a limiting factor, such as very small animal imaging. Several methods for the recovery of ICS events have been proposed, many of which aim to locate the first interaction, i.e., the Compton scattering site, usually limited by their success rate, computational burden or data and training dependency. Conversely, this work proposes a physics-based model for ICS events, leading to analytical expressions of the sensitivity image and the system matrix (required by statistical reconstruction algorithms), without the need to identify the original line of response. After validating the model, the work shows how ICS events can be integrated into a joint image reconstruction algorithm (based on list-mode MLEM) together with conventional PET events, for which dedicated analytical models are also developed. To assess the performance of the proposed approach, Monte-Carlo simulated and experimental data of an image quality phantom were obtained with the MERMAID small-fish PET scanner prototype. Both simulation and experimental results indicate that, while slightly decreasing the recovery coefficient values, the inclusion of ICS clearly reduces statistical noise and improves uniformity.

physics.med-ph

Stopping power monitoring during proton therapy by means of prompt gamma timing: first experimental results with a homogeneous phantom

Proton therapy's full potential is limited by uncertainties that prevent optimal dose distribution. Monitoring techniques can reduce these uncertainties and enable adaptive treatment planning. Spatiotemporal Emission Reconstruction from Prompt-Gamma Timing (SER-PGT) is a promising method that provides insights into both particle range and stopping power, whose calculation would normally require knowledge about patient tissue properties that cannot be directly measured. We present the first experimental results using a 226.9 MeV synchrotron-proton beam impinging on a homogeneous phantom at a sub-clinical intensity (2 - 4 x 10^7 pps). SER-PGT uses data from a multi-detector setup: a thin and segmented Low Gain Avalanche Diode for proton detection and Lanthanum Bromide-based crystals for photon detection. The estimated stopping power profile showed an 8% +- 3% average error compared to NIST PSTAR values, and 2% +- 2% deviation relative to water at 100 MeV. Range assessment in a phantom with a 4 cm air-gap successfully identified the range shift with a 3 mm standard deviation. These results demonstrate the feasibility of using SER-PGT to recover both range and stopping power information through particle kinematics and PGT measurements.

physics.med-ph

Analytical Model of Prompt Gamma Timing for Spatiotemporal Emission Reconstruction in Particle Therapy

Particle therapy relies on up-to-date knowledge of the stopping power of the patient tissues to deliver the prescribed dose distribution. The stopping power describes the average particle motion, which is encoded in the distribution of prompt-gamma photon emissions in time and space. We reconstruct the spatiotemporal emission distribution from multi-detector Prompt Gamma Timing (PGT) data. Solving this inverse problem relies on an accurate model of the prompt-gamma transport and detection including explicitly the dependencies on the time of emission and detection. Our previous work relied on Monte-Carlo (MC) based system models. The tradeoff between computational resources and statistical noise in the system model prohibits studies of new detector arrangements and beam scanning scenarios. Therefore, we propose here an analytical system model to speed up recalculations for new beam positions and to avoid statistical noise in the model. We evaluated the model for the MERLINO multi-detector-PGT prototype. Comparisons between the analytical model and a MC-based reference showed excellent agreement for single-detector setups. When several detectors were placed close together and partially obstructed each other, intercrystal scatter led to differences of up to 10 % between the analytical and MC-based model. Nevertheless, when evaluating the performance in reconstructing the spatiotemporal distribution and estimating the stopping power, no significant difference between the models was observed. Hence, the procedure proved robust against the small inaccuracies of the model for the tested scenarios. The model calculation time was reduced by 1500 times, now enabling many new studies for PGT-based systems.

physics.med-ph

First experimental test of a coded-mask gamma camera for proton therapy monitoring

Objective. The objective of the presented study was to evaluate the feasibility of a coded-mask (CM) gamma camera for real-time range verification in proton therapy, addressing the need for a precise and efficient method of treatment monitoring. Approach. A CM gamma camera prototype was tested in clinical conditions. The setup incorporated a scintillator-based detection system and a structured tungsten collimator. The experiment consisted of the irradiation of PMMA phantom with proton beams of energies ranging from 70.51 to 108.15 MeV. Experimental data were benchmarked against Monte Carlo simulations. The distal falloff position was determined for both experimental data and simulations. Main results. The tested CM camera achieved a statistical precision of distal falloff position determination of 1.7 mm for $10^8$ protons, which is consistent with simulation predictions, despite hardware limitations such as non-functional detector pixels. Simulations indicated that a fully operational setup would further improve the performance of the detector. The system demonstrated rate capability sufficient for clinical proton beam intensities and maintained performance without significant dead time. Significance. This study validates the potential of the CM gamma camera for real-time proton therapy monitoring. The technology promises to enhance treatment accuracy and patient safety, offering a competitive alternative to existing approaches such as single-slit and multi-slit systems.

physics.med-ph

Near-field coded-mask technique and its potential for proton therapy monitoring

Objective. Prompt-gamma imaging encompasses several approaches for online monitoring of beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques - a coded mask approach - both experimentally and via simulations. Approach. Two imaging setups have been investigated experimentally. Each of them comprised a structured tungsten collimator in a form of a MURA mask and a LYSO:Ce scintillation detector of fine granularity. The setups differed in the detector dimensions and the operation mode (1D or 2D imaging). A series of measurements with radioactive sources have been conducted, testing the setups' performance of near-field gamma imaging. Additionally, Monte Carlo simulations of a larger setup of the same type were conducted, investigating its performance with a realistic gamma source distribution occurring during proton therapy. Main results. The images of point-like sources reconstructed from two smallscale prototypes' data using the MLEM algorithm constitute the experimental proof of principle for the near-field coded-mask imaging modality, both in the 1D and the 2D mode. Their precision allowed us to calibrate out certain systematic offsets appearing due to the misalignment of setup elements. The simulation of the full-scale setup yielded a mean distal falloff retrieval precision of 0.72 mm in the studies for beam energy range 89.5-107.9 MeV and with 1x10^8 protons (typical number for single distal spots). The implemented algorithm of image reconstruction is relatively fast - a typical procedure needs several seconds. Significance. Coded-mask imaging appears a valid option for proton therapy monitoring. The results of simulations let us conclude that the proposed fullscale setup is competitive to the knife-edge-shaped and the multiparalell slit cameras investigated by other groups.

physics.med-ph