SearcharxivSearch

arXiv subjects

Maju Kuriakose

Publications and source records attributed to Maju Kuriakose.

2 recordsLinked to original sources

Spatial resolution in optical coherence elastography of bounded media

Dynamic optical coherence elastography (OCE) tracks mechanical wave propagation in the subsurface region of tissue to image its shear modulus. For bulk shear waves, the lateral resolution of the reconstructed modulus map (i.e., elastographic resolution) can approach optical coherence tomography (OCT) capabilities, typically a few tens of microns. Here we perform comprehensive numerical simulations and acoustic micro-tapping OCE experiments to show that for the typical situation of guided wave propagation in bounded media, such as cornea, the elastographic resolution cannot reach the OCT resolution and is mainly defined by the thickness of the bounded tissue layer. We considered the excitation of both broadband and quasi-harmonic guided waves in a bounded, isotropic medium. Leveraging the properties of broadband pulses, a robust method for modulus reconstruction with minimum artifacts at interfaces is demonstrated. In contrast, tissue bounding creates large instabilities in the phase of harmonic waves, leading to serious artifacts in modulus reconstructions.

physics.optics

Forward model for quantitative pulse-echo speed-of-sound imaging

Computed ultrasound tomography in echo mode (CUTE) allows determining the spatial distribution of speed-of-sound (SoS) inside tissue using handheld pulse-echo ultrasound (US). This technique is based on measuring the changing phase of beamformed echoes obtained under varying transmit (Tx) and/or receive (Rx) steering angles. The SoS is reconstructed by inverting a forward model describing how the spatial distribution of SoS is related to the spatial distribution of the echo phase shift. CUTE holds promise as a novel diagnostic modality that complements conventional US in a single, real-time handheld system. Here we demonstrate that, in order to obtain robust quantitative results, the forward model must contain two features that were not taken into account so far: a) the phase shift must be detected between pairs of Tx and Rx angles that are centred around a set of common mid-angles, and b) it must account for an additional phase shift induced by the error of the reconstructed position of echoes. In a phantom study mimicking liver imaging, this new model leads to a substantially improved quantitative SoS reconstruction compared to the model that has been used so far. The importance of the new model as a prerequisite for an accurate diagnosis is corroborated in preliminary volunteer results.

physics.med-ph