Searcharxiv⌕ Search

arXiv subjects

Mamun Bin Ibne Reaz

Publications and source records attributed to Mamun Bin Ibne Reaz.

14 recordsLinked to original sources

FORS-EMG: A Novel sEMG Dataset for Hand Gesture Recognition Across Multiple Forearm Orientations

Surface electromyography (sEMG) signals hold significant potential for gesture recognition and robust prosthetic hand development. However, sEMG signals are affected by various physiological and dynamic factors, including forearm orientation, electrode displacement, and limb position. Most existing sEMG datasets lack these dynamic considerations. This study introduces a novel multichannel sEMG dataset to evaluate commonly used hand gestures across three distinct forearm orientations. The dataset was collected from nineteen able-bodied subjects performing twelve hand gestures in three forearm orientations--supination, rest, and pronation. Eight MFI EMG electrodes were strategically placed at the elbow and mid-forearm to record high-quality EMG signals. Signal quality was validated through Signal-to-Noise Ratio (SNR) and Signal-to-Motion artifact ratio (SMR) metrics. Hand gesture classification performance across forearm orientations was evaluated using machine learning classifiers, including LDA, SVM, and KNN, alongside five feature extraction methods: TDD, TSD, FTDD, AR-RMS, and SNTDF. Furthermore, deep learning models such as 1D CNN, RNN, LSTM, and hybrid architectures were employed for a comprehensive analysis. Notably, the LDA classifier achieved the highest F1 score of 88.58\% with the SNTDF feature set when trained on hand gesture data of resting and tested across gesture data of all orientations. The promising results from extensive analyses underscore the proposed dataset's potential as a benchmark for advancing gesture recognition technologies, clinical sEMG research, and human-computer interaction applications. The dataset is publicly available in MATLAB format. Dataset: \url{https://www.kaggle.com/datasets/ummerummanchaity/fors-emg-a-novel-semg-dataset}

eess.SP↗

An exploratory analysis of Community-based Question-Answering Platforms and GPT-3-driven Generative AI: Is it the end of online community-based learning?

Context: The advent of Large Language Model-driven tools like ChatGPT offers software engineers an interactive alternative to community question-answering (CQA) platforms like Stack Overflow. While Stack Overflow provides benefits from the accumulated crowd-sourced knowledge, it often suffers from unpleasant comments, reactions, and long waiting times. Objective: In this study, we assess the efficacy of ChatGPT in providing solutions to software engineering questions by analyzing its performance specifically against human solutions. Method: We empirically analyze 2564 Python and JavaScript questions from StackOverflow that were asked between January 2022 and December 2022. We parse the questions and answers from Stack Overflow, then collect the answers to the same questions from ChatGPT through API, and employ four textual and four cognitive metrics to compare the answers generated by ChatGPT with the accepted answers provided by human subject matter experts to find out the potential reasons for which future knowledge seekers may prefer ChatGPT over CQA platforms. We also measure the accuracy of the answers provided by ChatGPT. We also measure user interaction on StackOverflow over the past two years using three metrics to determine how ChatGPT affects it. Results: Our analysis indicates that ChatGPT's responses are 66% shorter and share 35% more words with the questions, showing a 25% increase in positive sentiment compared to human responses. ChatGPT's answers' accuracy rate is between 71 to 75%, with a variation in response characteristics between JavaScript and Python. Additionally, our findings suggest a recent 38% decrease in comment interactions on Stack Overflow, indicating a shift in community engagement patterns. A supplementary survey with 14 Python and JavaScript professionals validated these findings.

cs.SE↗

Impact of Electrode Position on Forearm Orientation Invariant Hand Gesture Recognition

Objective: Variation of forearm orientation is one of the crucial factors that drastically degrades the forearm orientation invariant hand gesture recognition performance or the degree of freedom and limits the successful commercialization of myoelectric prosthetic hand or electromyogram (EMG) signal-based human-computer interfacing devices. This study investigates the impact of surface EMG electrode positions (elbow and forearm) on forearm orientation invariant hand gesture recognition. Methods: The study has been performed over 19 intact limbed subjects, considering 12 daily living hand gestures. The quality of the EMG signal is confirmed in terms of three indices. Then, the recognition performance is evaluated and validated by considering three training strategies, six feature extraction methods, and three classifiers. Results: The forearm electrode position provides comparable to or better EMG signal quality considering three indices. In this research, the forearm electrode position achieves up to 5.35% improved forearm orientation invariant hand gesture recognition performance compared to the elbow electrode position. The obtained performance is validated by considering six feature extraction methods, three classifiers, and real-time experiments. In addition, the forearm electrode position shows its robustness with the existence of recent works, considering recognition performance, investigated gestures, the number of channels, the dimensionality of feature space, and the number of subjects. Conclusion: The forearm electrode position can be the best choice for getting improved forearm orientation invariant hand gesture recognition performance. Significance: The performance of myoelectric prosthesis and human-computer interfacing devices can be improved with this optimized electrode position.

cs.HC↗

Bangladeshi Native Vehicle Detection in Wild

The success of autonomous navigation relies on robust and precise vehicle recognition, hindered by the scarcity of region-specific vehicle detection datasets, impeding the development of context-aware systems. To advance terrestrial object detection research, this paper proposes a native vehicle detection dataset for the most commonly appeared vehicle classes in Bangladesh. 17 distinct vehicle classes have been taken into account, with fully annotated 81542 instances of 17326 images. Each image width is set to at least 1280px. The dataset's average vehicle bounding box-to-image ratio is 4.7036. This Bangladesh Native Vehicle Dataset (BNVD) has accounted for several geographical, illumination, variety of vehicle sizes, and orientations to be more robust on surprised scenarios. In the context of examining the BNVD dataset, this work provides a thorough assessment with four successive You Only Look Once (YOLO) models, namely YOLO v5, v6, v7, and v8. These dataset's effectiveness is methodically evaluated and contrasted with other vehicle datasets already in use. The BNVD dataset exhibits mean average precision(mAP) at 50% intersection over union (IoU) is 0.848 corresponding precision and recall values of 0.841 and 0.774. The research findings indicate a mAP of 0.643 at an IoU range of 0.5 to 0.95. The experiments show that the BNVD dataset serves as a reliable representation of vehicle distribution and presents considerable complexities.

cs.CV↗

Optimisation and Performance Computation of a Phase Frequency Detector Module for IoT Devices

The Internet of Things (IoT) is pivotal in transforming the way we live and interact with our surroundings. To cope with the advancement in technologies, it is vital to acquire accuracy with the speed. A phase frequency detector (PFD) is a critical device to regulate and provide accurate frequency in IoT devices. Designing a PFD poses challenges in achieving precise phase detection, minimising dead zones, optimising power consumption, and ensuring robust performance across various operational frequencies, necessitating complex engineering and innovative solutions. This study delves into optimising a PFD circuit, designed using 90 nm standard CMOS technology, aiming to achieve superior operational frequencies. An efficient and high-frequency PFD design is crafted and analysed using cadence virtuoso. The study focused on investigating the impact of optimising PFD design. With the optimised PFD, an operational frequency of 5 GHz has been achieved, along with a power consumption of only 29 μW. The dead zone of the PFD was only 25 ps.

cs.NI↗

Design, Implementation, and Performance Evaluation of a Fiber Bragg Gratings(FBG) based Smart Insole to Measure Plantar Pressure and Temperature

Various foot complications can be easily avoided by continuous monitoring of foot plantar temperature and pressure. In this work, the design, characterization, and implementation of a Fiber Bragg Gratings (FBG) based smart insole capable of simultaneously measuring plantar pressure and temperature has been reported. The instrumented insole was tested and verified during static and gait exercises. The paper also provides a comparison of the developed optoelectronic-based solution with a commercially available and widely used plantar pressure measurement and analysis system and a lab-made, electronic sensor-based smart insole that can measure both plantar temperature and pressure. It was shown that even though the commercially available expensive system is very robust and highly precise due to many sensing units on the insole, the developed insole with a smaller number of sensors can provide both plantar temperature and pressure with reasonable precision while displaying both foot pressure and temperature maps, and gait cycle plots in real-time. The FBG-based solution is comfortable and safer than the other systems being compared. Thus, confirming the effectiveness of the proposed solution as an addition to the research area for detecting foot complications non-invasively using foot insoles.

eess.SY↗

Design and Implementation of a Complete Wearable Smart Insole Solution to Measure Plantar Pressure and Temperature

A complete smart insole solution that continuously monitors the foot plantar pressure and temperature can detect foot complications early and that too from the convenience of the user home. Widespread health complications such as Diabetic Mellitus need continuous foot complication monitoring to avoid severe complications. With that motivation, this paper provides a detailed design of a wearable insole using popular off-the-shelf sensors to monitor foot plantar pressure and temperature. The design provides details of which temperature and pressure to be used, circuit configuration for characterizing the sensors, and the considerations for developing a compact Printed Circuit board design using appropriate microcontrollers and communication protocol. The system also provides details of how the foot pressure and temperature data from the subjects using the sensors can be transferred wirelessly using a low-power consuming communication protocol to a central device where the data will be recorded. The investigation can help in developing a low-cost, feasible and portable foot monitoring system for patients by facilitating real-time, home monitoring of foot condition using Gait Cycle or Foot Pressure patterns and temperature heterogeneity between two feet. The proposed system will work in real-time.

physics.med-ph↗

Evaluating Performance of Machine Learning Models for Diabetic Sensorimotor Polyneuropathy Severity Classification using Biomechanical Signals during Gait

Diabetic sensorimotor polyneuropathy (DSPN) is one of the prevalent forms of neuropathy affected by diabetic patients that involves alterations in biomechanical changes in human gait. In literature, for the last 50 years, researchers are trying to observe the biomechanical changes due to DSPN by studying muscle electromyography (EMG), and ground reaction forces (GRF). However, the literature is contradictory. In such a scenario, we are proposing to use Machine learning techniques to identify DSPN patients by using EMG, and GRF data. We have collected a dataset consists of three lower limb muscles EMG (tibialis anterior (TA), vastus lateralis (VL), gastrocnemius medialis (GM) and 3-dimensional GRF components (GRFx, GRFy, and GRFz). Raw EMG and GRF signals were preprocessed, and a newly proposed feature extraction technique scheme from literature was applied to extract the best features from the signals. The extracted feature list was ranked using Relief feature ranking techniques, and highly correlated features were removed. We have trained different ML models to find out the best-performing model and optimized that model. We trained the optimized ML models for different combinations of muscles and GRF components features, and the performance matrix was evaluated. This study has found ensemble classifier model was performing in identifying DSPN Severity, and we optimized it before training. For EMG analysis, we have found the best accuracy of 92.89% using the Top 14 features for features from GL, VL and TA muscles combined. In the GRF analysis, the model showed 94.78% accuracy by using the Top 15 features for the feature combinations extracted from GRFx, GRFy and GRFz signals. The performance of ML-based DSPN severity classification models, improved significantly, indicating their reliability in DSPN severity classification, for biomechanical data.

cs.LG↗

Motion Artifacts Correction from Single-Channel EEG and fNIRS Signals using Novel Wavelet Packet Decomposition in Combination with Canonical Correlation Analysis

The electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) signals, highly non-stationary in nature, greatly suffers from motion artifacts while recorded using wearable sensors. This paper proposes two robust methods: i) Wavelet packet decomposition (WPD), and ii) WPD in combination with canonical correlation analysis (WPD-CCA), for motion artifact correction from single-channel EEG and fNIRS signals. The efficacy of these proposed techniques is tested using a benchmark dataset and the performance of the proposed methods is measured using two well-established performance matrices: i) Difference in the signal to noise ratio (ΔSNR) and ii) Percentage reduction in motion artifacts (η). The proposed WPD-based single-stage motion artifacts correction technique produces the highest average ΔSNR (29.44 dB) when db2 wavelet packet is incorporated whereas the greatest average η (53.48%) is obtained using db1 wavelet packet for all the available 23 EEG recordings. Our proposed two-stage motion artifacts correction technique i.e. the WPD-CCA method utilizing db1 wavelet packet has shown the best denoising performance producing an average ΔSNR and η values of 30.76 dB and 59.51%, respectively for all the EEG recordings. On the other hand, the two-stage motion artifacts removal technique i.e. WPD-CCA has produced the best average ΔSNR (16.55 dB, utilizing db1 wavelet packet) and largest average η (41.40%, using fk8 wavelet packet). The highest average ΔSNR and η using single-stage artifacts removal techniques (WPD) are found as 16.11 dB and 26.40%, respectively for all the fNIRS signals using fk4 wavelet packet. In both EEG and fNIRS modalities, the percentage reduction in motion artifacts increases by 11.28% and 56.82%, respectively when two-stage WPD-CCA techniques are employed.

cs.LG↗

Myoelectric Pattern Recognition Performance Enhancement Using Nonlinear Features

The multichannel electrode array used for electromyogram (EMG) pattern recognition provides good performance, but it has a high cost, is computationally expensive, and is inconvenient to wear. Therefore, researchers try to use as few channels as possible while maintaining improved pattern recognition performance. However, minimizing the number of channels affects the performance due to the least separable margin among the movements possessing weak signal strengths. To meet these challenges, two time-domain features based on nonlinear scaling, the log of the mean absolute value (LMAV) and the nonlinear scaled value (NSV), are proposed. In this study, we validate the proposed features on two datasets, existing four feature extraction methods, variable window size and various signal to noise ratios (SNR). In addition, we also propose a feature extraction method where the LMAV and NSV are grouped with the existing 11 time-domain features. The proposed feature extraction method enhances accuracy, sensitivity, specificity, precision, and F1 score by 1.00%, 5.01%, 0.55%, 4.71%, and 5.06% for dataset 1, and 1.18%, 5.90%, 0.66%, 5.63%, and 6.04% for dataset 2, respectively. Therefore, the experimental results strongly suggest the proposed feature extraction method, for taking a step forward with regard to improved myoelectric pattern recognition performance.

eess.SP↗

A Machine Learning Model for Early Detection of Diabetic Foot using Thermogram Images

Diabetes foot ulceration (DFU) and amputation are a cause of significant morbidity. The prevention of DFU may be achieved by the identification of patients at risk of DFU and the institution of preventative measures through education and offloading. Several studies have reported that thermogram images may help to detect an increase in plantar temperature prior to DFU. However, the distribution of plantar temperature may be heterogeneous, making it difficult to quantify and utilize to predict outcomes. We have compared a machine learning-based scoring technique with feature selection and optimization techniques and learning classifiers to several state-of-the-art Convolutional Neural Networks (CNNs) on foot thermogram images and propose a robust solution to identify the diabetic foot. A comparatively shallow CNN model, MobilenetV2 achieved an F1 score of ~95% for a two-feet thermogram image-based classification and the AdaBoost Classifier used 10 features and achieved an F1 score of 97 %. A comparison of the inference time for the best-performing networks confirmed that the proposed algorithm can be deployed as a smartphone application to allow the user to monitor the progression of the DFU in a home setting.

eess.IV↗

Multimodal EEG and Keystroke Dynamics Based Biometric System Using Machine Learning Algorithms

With the rapid advancement of technology, different biometric user authentication, and identification systems are emerging. Traditional biometric systems like face, fingerprint, and iris recognition, keystroke dynamics, etc. are prone to cyber-attacks and suffer from different disadvantages. Electroencephalography (EEG) based authentication has shown promise in overcoming these limitations. However, EEG-based authentication is less accurate due to signal variability at different psychological and physiological conditions. On the other hand, keystroke dynamics-based identification offers high accuracy but suffers from different spoofing attacks. To overcome these challenges, we propose a novel multimodal biometric system combining EEG and keystroke dynamics. Firstly, a dataset was created by acquiring both keystroke dynamics and EEG signals from 10 users with 500 trials per user at 10 different sessions. Different statistical, time, and frequency domain features were extracted and ranked from the EEG signals and key features were extracted from the keystroke dynamics. Different classifiers were trained, validated, and tested for both individual and combined modalities for two different classification strategies - personalized and generalized. Results show that very high accuracy can be achieved both in generalized and personalized cases for the combination of EEG and keystroke dynamics. The identification and authentication accuracies were found to be 99.80% and 99.68% for Extreme Gradient Boosting (XGBoost) and Random Forest classifiers, respectively which outperform the individual modalities with a significant margin (around 5 percent). We also developed a binary template matching-based algorithm, which gives 93.64% accuracy 6X faster. The proposed method is secured and reliable for any kind of biometric authentication.

cs.CR↗

Can AI help in screening Viral and COVID-19 pneumonia?

Coronavirus disease (COVID-19) is a pandemic disease, which has already caused thousands of causalities and infected several millions of people worldwide. Any technological tool enabling rapid screening of the COVID-19 infection with high accuracy can be crucially helpful to healthcare professionals. The main clinical tool currently in use for the diagnosis of COVID-19 is the Reverse transcription polymerase chain reaction (RT-PCR), which is expensive, less-sensitive and requires specialized medical personnel. X-ray imaging is an easily accessible tool that can be an excellent alternative in the COVID-19 diagnosis. This research was taken to investigate the utility of artificial intelligence (AI) in the rapid and accurate detection of COVID-19 from chest X-ray images. The aim of this paper is to propose a robust technique for automatic detection of COVID-19 pneumonia from digital chest X-ray images applying pre-trained deep-learning algorithms while maximizing the detection accuracy. A public database was created by the authors combining several public databases and also by collecting images from recently published articles. The database contains a mixture of 423 COVID-19, 1485 viral pneumonia, and 1579 normal chest X-ray images. Transfer learning technique was used with the help of image augmentation to train and validate several pre-trained deep Convolutional Neural Networks (CNNs). The networks were trained to classify two different schemes: i) normal and COVID-19 pneumonia; ii) normal, viral and COVID-19 pneumonia with and without image augmentation. The classification accuracy, precision, sensitivity, and specificity for both the schemes were 99.7%, 99.7%, 99.7% and 99.55% and 97.9%, 97.95%, 97.9%, and 98.8%, respectively.

cs.LG↗

Estimating Blood Pressure from Photoplethysmogram Signal and Demographic Features using Machine Learning Techniques

Hypertension is a potentially unsafe health ailment, which can be indicated directly from the Blood pressure (BP). Hypertension always leads to other health complications. Continuous monitoring of BP is very important; however, cuff-based BP measurements are discrete and uncomfortable to the user. To address this need, a cuff-less, continuous and a non-invasive BP measurement system is proposed using Photoplethysmogram (PPG) signal and demographic features using machine learning (ML) algorithms. PPG signals were acquired from 219 subjects, which undergo pre-processing and feature extraction steps. Time, frequency and time-frequency domain features were extracted from the PPG and their derivative signals. Feature selection techniques were used to reduce the computational complexity and to decrease the chance of over-fitting the ML algorithms. The features were then used to train and evaluate ML algorithms. The best regression models were selected for Systolic BP (SBP) and Diastolic BP (DBP) estimation individually. Gaussian Process Regression (GPR) along with ReliefF feature selection algorithm outperforms other algorithms in estimating SBP and DBP with a root-mean-square error (RMSE) of 6.74 and 3.59 respectively. This ML model can be implemented in hardware systems to continuously monitor BP and avoid any critical health conditions due to sudden changes.

eess.SP↗