SearcharxivSearch

arXiv subjects

Manoel Conde

Publications and source records attributed to Manoel Conde.

7 recordsLinked to original sources

Rapid thermal emittance and quantum efficiency mapping of a cesium telluride cathode in an rf photoinjector using multiple laser beamlets

Thermal emittance and quantum efficiency (QE) are key figures of merit of photocathodes, and their uniformity is critical to high-performance photoinjectors. Several QE mapping technologies have been successfully developed; however, there is still a dearth of information on thermal emittance maps. This is because of the extremely time-consuming procedure to gather measurements by scanning a small beam across the cathode with fine steps. To simplify the mapping procedure, and to reduce the time required to take measurements, we propose a new method that requires only a single scan of the solenoid current to simultaneously obtain thermal emittance and QE distribution by using a pattern beam with multiple beamlets. In this paper, its feasibility has been confirmed by both beam dynamics simulation and theoretical analysis. The method has been successfully demonstrated in a proof-of-principle experiment using an L-band radiofrequency photoinjector with a cesium telluride cathode. In the experiment, seven beamlets were generated from a microlens array system and their corresponding thermal emittance and QE varied from 0.93 to 1.14 $μ$m/mm and from 4.6 to 8.7%, respectively. We also discuss the limitations and future improvements of the method in this paper.

physics.acc-ph

Systematic benchmarking of planar nitrogen-incorporated ultrananocrystalline diamond field emission electron source: rf conditioning and beam spatio-temporal characteristics

Planar nitrogen-incorporated ultrananocrystalline diamond, (N)UNCD, has emerged as a unique field emission source attractive for accelerator applications because of its capability to generate high charge beam and handle moderate vacuum conditions. Most importantly, (N)UNCD sources are simple to produce: conventional high aspect ratio isolated emitters are not required to be formed on the surface, and the actual emitter surface roughness is on the order of only 100~nm. Careful reliability assessment of (N)UNCD is required before it may find routine application in accelerator systems. In the present study using an L-band normal conducting single-cell rf gun, a (N)UNCD cathode has been conditioned to $\sim$42~MV/m in a well-controlled manner. It reached a maximum output charge of 15~nC corresponding to an average current of 6~mA during an emission period of 2.5~$μ$s. Imaging of emission current revealed a large number of isolated emitters (density over 100/cm$^{2}$) distributed on the cathode, which is consistent with previous tests in dc environments. The performance metrics, the emission imaging, and the systematic study of emission properties during rf conditioning in a wide gradient range assert (N)UNCD as an enabling electron source for rf injector designs serving industrial and scientific applications. These studies also improve the fundamental knowledge of the practical conditioning procedure via better understanding of emission mechanisms.

physics.acc-ph

Transition radiation in photonic topological crystals: quasi-resonant excitation of robust edge states by a moving charge

We demonstrate, theoretically and experimentally, that a traveling electric charge passing from one photonic crystal into another generates edge waves -- electromagnetic modes with frequencies inside the common photonic bandgap localized at the interface -- via a process of transition edge-wave radiation (TER). A simple and intuitive expression for the TER spectral density is derived and then applied to a specific structure: two interfacing photonic topological insulators with opposite spin-Chern indices. We show that TER breaks the time-reversal symmetry and enables valley- and spin-polarized generation of topologically protected edge waves propagating in one or both directions along the interface. Experimental measurements at the Argonne Wakefield Accelerator Facility are consistent with the excitation and localization of the edge waves. The concept of TER paves the way for novel particle accelerators and detectors.

physics.optics

Development and high-power testing of an X-band dielectric-loaded power extractor

Dielectric loaded structures are promising candidates for use in the structure wakefield acceleration (SWFA) technique, for both the collinear wakefield and the two-beam acceleration (CWA and TBA respectively) approaches, due to their low fabrication cost, low rf losses, and the potential to withstand high gradient. A short pulse (<=20 ns) TBA program is under development at the Argonne Wakefield Accelerator (AWA) facility where dielectric loaded structures are being used for both the power extractor/transfer structure (PETS) and the accelerator. In this study, an X-band 11.7 GHz dielectric PETS was developed and tested at the AWA facility to demonstrate high power wakefield generation. The PETS was driven by a train of eight electron bunches separated by 769.2 ps (9 times of the X-band rf period) in order to achieve coherent wakefield superposition. A total train charge of 360 nC was passed through the PETS structure to generate ~200 MW, ~3 ns flat-top rf pulses without rf breakdown. A future experiment is being planned to increase the generated rf power to approximately ~1 GW by optimizing the structure design and improving the drive beam quality.

physics.acc-ph

Experimental demonstration of the correction of coupled transverse dynamics aberration in an rf photoinjector

The production of electron bunches with low transverse emittance approaches the thermal emittance of the photocathode as various aberrations are corrected. Recently, the coupled transverse dynamics aberration was theoretically identified as a significant source of emittance growth and a corrector magnet was proposed for its elimination [D.H. Dowell, F. Zhou, and J. Schmerge, PRAB 21, 010101 (2018)]. This aberration arises when the beam acquires an asymmetric distribution that is then rotated with respect to the transverse reference axis thus introducing a correlation in the vertical and horizontal planes. The asymmetry is introduced by a weak quadrupole field in the rf gun or emittance compensation solenoid and the rotation is caused by the solenoid. This Letter presents an experimental study of the coupled transverse dynamics aberration in an rf photoinjector and demonstrates its elimination by a quadrupole corrector consisting of a normal and a skew quadrupole. The experimental results agree well with theoretical predictions and numerical simulations. The study also demonstrates the emittance of a low charge beam can be preserved during transportation at its thermal value, which was 1.05 mm mrad/mm, for the cesium telluride photocathode and 248 nm UV laser used.

physics.acc-ph

Overestimation of thermal emittance in solenoid scans due to coupled transverse motion

The solenoid scan is a widely used method for the in-situ measurement of the thermal emittance in a photocathode gun. The popularity of this method is due to its simplicity and convenience since all rf photocathode guns are equipped with an emittance compensation solenoid. This paper shows that the solenoid scan measurement overestimates the thermal emittance in the ordinary measurement configuration due to a weak quadrupole field (present in either the rf gun or gun solenoid) followed by a rotation in the solenoid. This coupled transverse dynamics aberration introduces a correlation between the beam's horizontal and vertical motion leading to an increase in the measured 2D transverse emittance, thus the overestimation of the thermal emittance. This effect was systematically studied using both analytic expressions and numerical simulations. These studies were experimentally verified using an L-band 1.6-cell rf photocathode gun with a cesium telluride cathode, which shows a thermal emittance overestimation of 35% with a rms laser spot size of 2.7 mm. The paper concludes by showing that the accuracy of the solenoid scan can be improved by using a quadrupole magnet corrector, consisting of a pair of normal and skew quadrupole magnets.

physics.acc-ph

In situ Observation of Dark Current Emission in a High Gradient RF Photocathode Gun

Undesirable electron field emission (a.k.a. dark current) in high gradient RF photocathode guns deteriorates the quality of photoemission current and limits the operational gradient. To improve the understanding of dark current emission, a high-resolution (~100 um) dark current imaging experiment has been performed in an L-band photocathode gun operating at ~100 MV/m of surface gradient. Dark current from the cathode has been observed to be dominated by several separated strong emitters. The field enhancement factor, beta, of selected regions on the cathode has been measured. The post scanning electron microscopy (SEM) and white light interferometer (WLI) surface examinations reveal the origins of ~75% strong emitters overlap with the spots where rf breakdown have occurred.

physics.acc-ph