SearcharxivSearch

arXiv subjects

Manoj Kumar Sharma

Publications and source records attributed to Manoj Kumar Sharma.

3 recordsLinked to original sources

Investigating the fission-like fragments in the $^{12}$C + $^{208}$Pb system at E$^{\star}$ $\approx$ 31.8--45.4 MeV

In this work, the cross-sections of 25 fission-like fragments within the mass range 76$\leq$A$\leq$141, expected to be populated via fission of moderately excited compound nucleus produced as a result of complete and/or incomplete fusion in $^{12}$C+$^{208}$Pb reaction at E$_{\rm lab}$ = 81.9 and 75.8 MeV, have been measured using activation technique followed by offline $\gamma$-ray spectroscopy. The yields of different fission-like fragments have been analyzed to generate isotopic and isobaric yield distributions. The value of the mass dispersion parameter, $\sigma^2_A$, is found to be 2.93 and 2.65 for Antimony (Sb) isotope at excitation energy E$^{\star}$ = 45.4 and 39.6 MeV, and 1.24 for Indium (In) isotope at E$^{\star}$ = 45.4 MeV. The charge dispersion parameter $\sigma_Z$ for Sb is estimated to be 0.769 and 0.714 at E$^{\star}$ = 45.4 and 39.6 MeV, respectively. For In isotopes, the value of $\sigma_Z$ is estimated to be 0.430 at E$^{\star}$ = 45.4 MeV. The value of mass and charge dispersion parameters for Sb and In isotopes have been found to be in good agreement with the values reported in the literature for similar systems. The mass distribution of fission-like fragments is found to be fitted with a Gaussian function, except for a few data points, indicating their population via compound nucleus fission. Further, the mass variance ($\sigma^2_M$) displays linear increment with an increase in excitation energy. Two medically important isotopes, $^{99m}$Tc and $^{111}$In, are populated in this system, suggesting a potential formation route.

nucl-ex

Incomplete fusion in $^{193}$Ir($^{12}$C, x)$^{205}$Bi reaction at $E_{lab}$ $\approx$ 5-7 AMeV

Low-energy heavy-ion induced reactions often involve incomplete fusion, but the dependence of ICF on various entrance-channel parameters remains unclear. In this work, we measure channel-by-channel production cross-sections of different evaporation residues populated via complete and/or incomplete fusion in $^{12}$C+$^{193}$Ir system at $E_{lab}$ $\approx$ 64--84 MeV ($\approx$ 5--7 AMeV) using the stacked-foil activation technique followed by offline $\gamma$-spectroscopy. Experimentally measured excitation functions have been analyzed in the framework of the statistical model code PACE4 using different values of the level-density parameter ($a$ = A/9-A/15 MeV${^{-1}}$). In the analysis of excitation functions, the $xn$ and $pxn$ channels (after correcting with their precursor contributions) have been explained fairly well with $a$ = A/13 MeV${^{-1}}$; however, almost all $\alpha$-emitting channels showed substantial enhancement over PACE4 predictions, which has been attributed to incomplete fusion. The incomplete fusion fraction ($F_{ICF}$) increases linearly with energy from 12\% to 18\% at 64 and 84 MeV, respectively. For better insights into the onset and strength of ICF, the variations of $F_{ICF}$ have been studied as a function of different entrance-channel parameters, which are found to increase with mass asymmetry, Coulomb factor, and neutron skin thickness. Further analysis of the data suggests the onset of ICF below the critical angular momentum ($\ell<\ell_{crit}$). Projectile breakup-driven incomplete fusion is found to suppress complete fusion by $\approx12\%$ and $\approx6\%$ w.r.t. the universal fusion function and the improved fusion function, respectively. These findings highlight the critical role of projectile structure at 5--7 AMeV energies, with implications for high-spin spectroscopy and reaction modeling.

nucl-ex

Toward Long Distance, Sub-diffraction Imaging Using Coherent Camera Arrays

In this work, we propose using camera arrays coupled with coherent illumination as an effective method of improving spatial resolution in long distance images by a factor of ten and beyond. Recent advances in ptychography have demonstrated that one can image beyond the diffraction limit of the objective lens in a microscope. We demonstrate a similar imaging system to image beyond the diffraction limit in long range imaging. We emulate a camera array with a single camera attached to an X-Y translation stage. We show that an appropriate phase retrieval based reconstruction algorithm can be used to effectively recover the lost high resolution details from the multiple low resolution acquired images. We analyze the effects of noise, required degree of image overlap, and the effect of increasing synthetic aperture size on the reconstructed image quality. We show that coherent camera arrays have the potential to greatly improve imaging performance. Our simulations show resolution gains of 10x and more are achievable. Furthermore, experimental results from our proof-of-concept systems show resolution gains of 4x-7x for real scenes. Finally, we introduce and analyze in simulation a new strategy to capture macroscopic Fourier Ptychography images in a single snapshot, albeit using a camera array.

cs.CV