SearcharxivSearch

arXiv subjects

Manojit Pramanik

Publications and source records attributed to Manojit Pramanik.

6 recordsLinked to original sources

HSD-PAM: High Speed Super Resolution Deep Penetration Photoacoustic Microscopy Imaging Boosted by Dual Branch Fusion Network

Photoacoustic microscopy (PAM) is a novel implementation of photoacoustic imaging (PAI) for visualizing the 3D bio-structure, which is realized by raster scanning of the tissue. However, as three involved critical imaging parameters, imaging speed, lateral resolution, and penetration depth have mutual effect to one the other. The improvement of one parameter results in the degradation of other two parameters, which constrains the overall performance of the PAM system. Here, we propose to break these limitations by hardware and software co-design. Starting with low lateral resolution, low sampling rate AR-PAM imaging which possesses the deep penetration capability, we aim to enhance the lateral resolution and up sampling the images, so that high speed, super resolution, and deep penetration for the PAM system (HSD-PAM) can be achieved. Data-driven based algorithm is a promising approach to solve this issue, thereby a dedicated novel dual branch fusion network is proposed, which includes a high resolution branch and a high speed branch. Since the availability of switchable AR-OR-PAM imaging system, the corresponding low resolution, undersample AR-PAM and high resolution, full sampled OR-PAM image pairs are utilized for training the network. Extensive simulation and in vivo experiments have been conducted to validate the trained model, enhancement results have proved the proposed algorithm achieved the best perceptual and quantitative image quality. As a result, the imaging speed is increased 16 times and the imaging lateral resolution is improved 5 times, while the deep penetration merit of AR-PAM modality is still reserved.

eess.IV

Multimodal imaging of the mouse eye using visible light photoacoustic ophthalmoscopy and near-infrared-II optical coherence tomography

Non-invasive imaging plays a crucial role in diagnosing and studying eye diseases. However, existing photoacoustic ophthalmoscopy (PAOM) techniques in mice have limitations due to handling restrictions, suboptimal optical properties, limited availability of light sources and permissible light fluence at the retina. This study introduces an innovative approach that utilizes Rose Bengal, a contrast agent, to enhance PAOM contrast. This enables visualization of deeper structures like the choroidal microvasculature and sclera in the mouse eye using visible light. The integration of near-infrared-II optical coherence tomography (NIR-II OCT) provides additional tissue contrast and insights into potential NIR-II PAOM capabilities. To optimize imaging, we developed a cost-effective 3D printable mouse eye phantom and a fully 3D printable tip/tilt mouse platform. This solution elevates PAOM to a user-friendly technology, which can be used to address pressing research questions concerning several ocular diseases such as myopia, glaucoma and/or age-related macular degeneration in the future.

physics.med-ph

Photo-acoustic tomographic image reconstruction from reduced data using physically inspired regularization

We propose a model-based image reconstruction method for photoacoustic tomography(PAT) involving a novel form of regularization and demonstrate its ability to recover good quality images from significantly reduced size datasets. The regularization is constructed to suit the physical structure of typical PAT images. We construct it by combining second-order derivatives and intensity into a non-convex form to exploit a structural property of PAT images that we observe: in PAT images, high intensities and high second-order derivatives are jointly sparse. The specific form of regularization constructed here is a modification of the form proposed for fluorescence image restoration. This regularization is combined with a data fidelity cost, and the required image is obtained as the minimizer of this cost. As this regularization is non-convex, the efficiency of the minimization method is crucial in obtaining artifact-free reconstructions. We develop a custom minimization method for efficiently handling this non-convex minimization problem. Further, as non-convex minimization requires a large number of iterations and the PAT forward model in the data-fidelity term has to be applied in the iterations, we propose a computational structure for efficient implementation of the forward model with reduced memory requirements. We evaluate the proposed method on both simulated and real measured data sets and compare them with a recent reconstruction method that is based on a well-known fast iterative shrinkage threshold algorithm (FISTA).

eess.IV

Sinogram super-resolution and denoising convolutional neural network (SRCN) for limited data photoacoustic tomography

The quality of the reconstructed photoacoustic image largely depends on the amount of photoacoustic (PA) boundary data available, which in turn is proportional to the number of detectors employed. In case of limited data (owing to less number of detectors due to cost/instrumentation constraints), the reconstructed PA images suffer from artifacts and are often noisy. In this work, for the first time, a deep learning based model was developed to super resolve and denoise the photoacoustic sinogram data. The proposed method was compared with existing nearest neighbor interpolation and wavelet based denoising techniques and was shown to outperform them both in numerical and in-vivo cases. The improvement obtained in Root Mean Square Error (RMSE) and Peak Signal to Noise Ratio (PSNR) for the reconstructed PA image using the sinogram data that was super-resolved and denoised using proposed neural network based method was as high as 41.70 % and 6.93 dB respectively compared to utilizing limited sinogram data.

eess.IV

Eigenspace-Based Minimum Variance Combined with Delay Multiply and Sum Beamformer: Application to Linear-Array Photoacoustic Imaging

In Photoacoustic imaging, Delay-and-Sum (DAS) algorithm is the most commonly used beamformer. However, it leads to a low resolution and high level of sidelobes. Delay-Multiply-and-Sum (DMAS) was introduced to provide lower sidelobes compared to DAS. In this paper, to improve the resolution and sidelobes of DMAS, a novel beamformer is introduced using Eigenspace-Based Minimum Variance (EIBMV) method combined with DMAS, namely EIBMV-DMAS. It is shown that expanding the DMAS algebra leads to several terms which can be interpreted as DAS. Using the EIBMV adaptive beamforming instead of the existing DAS (inside the DMAS algebra expansion) is proposed to improve the image quality. EIBMV-DMAS is evaluated numerically and experimentally. It is shown that EIBMV-DMAS outperforms DAS, DMAS and EIBMV in terms of resolution and sidelobes. In particular, at the depth of 11 mm of the experimental images, EIBMV-DMAS results in about 113 dB and 50 dB sidelobe reduction, compared to DMAS and EIBMV, respectively. At the depth of 7 mm, for the experimental images, the quantitative results indicate that EIBMV-DMAS leads to improvement in Signal-to-Noise Ratio (SNR) of about 75% and 34%, compared to DMAS and EIBMV, respectively.

eess.SP

An Efficient Nonlinear Beamformer Based on P^{th} Root of Detected Signals for Linear-Array Photoacoustic Tomography: Application to Sentinel Lymph Node Imaging

In linear-array transducer based photoacoustic (PA) imaging, B-scan PA images are formed using the raw channel PA signals. Delay-and-Sum (DAS) is the most prevalent algorithm due to its simple implementation, but it leads to low quality images. Delay-Multiply-and-Sum (DMAS) provides a higher image quality in comparison with DAS while it imposes a computational burden of O(M^2). In this work, we introduce a nonlinear (NL) beamformer for linear-array PA imaging, which uses the p^{th} root of the detected signals and imposes the complexity of DAS (O(M)). The proposed algorithm is evaluated numerically and experimentally (wire-target and in vivo sentinel lymph node (SLN) imaging), and the effects of the parameter p are investigated. The results show that the NL algorithm, using a root of p (NL_p), leads to lower sidelobes and higher signal-to-noise ratio (SNR) compared to DAS and DMAS, for (p > 2). The sidelobes level (for the wire-target phantom), at the depth of 11.4 mm, are about -31 dB, -52 dB, -52 dB, -67 dB, -88 dB and -109 dB, for DAS, DMAS, NL_2, NL_3, NL_4 and NL_5, respectively, indicating the superiority of the NL_p algorithm. In addition, the best value of p for SLN imaging is reported to be 12.

eess.SP